The design of a modernized standard for reproduction and transfer of the unit of ultrahigh frequency power in waveguides and coaxial channels and some studies of this system are described.
Similar content being viewed by others
References
V. G. Chuiko and V. D. Frumkin, “National special standard for the unit of power of electromagnetic oscillations in waveguide channels at frequencies of 2.59–37.5 GHz,” Izmer. Tekhn., No. 7, 4–5 (1974); Measur. Techn., 17, No. 7, 978–980 (1974).
GOST R 8.562-2007, GSI. State Verification Scheme for Means of Measuring the Power and Current of AC Sinusoidal Electromagnetic Oscillations.
N. R. Bazhenov, I. P. Chirkov, and V. G. Chuiko, “Automated system for calibration of low power microwave wattmeters,” Metrology in Radioelectronics: Abstr. 8th Sci. Techn. Conf., VNIIFTRI, Moscow (2006), pp. 46–47.
IEEE Std 287TM-2007, IEEE Standard for Precision Coaxial Connectors (DC to 110 GHz).
GOST 13317-89, Connector Components for Microwave Channels of Radio-Measurement Instruments. Connector Sizes.
V. A. Semenov and V. G. Chuiko, “A new type of coaxial standard microwave wattmeter,” Metrology in Radioelectronics: Abstr. 8th Sci. Techn. Conf., VNIIFTRI, Moscow (2006), pp. 48–50.
M. I. Bilko et al., Microwave Power Measurements [in Russian], Sov. Radio, Moscow (1976).
V. A. Semenov and V. G. Chuiko, “Measurement of the efficiency factor for thermoelectric converters of microwave wattmeters in a microcalorimeter,” Metrology in Radioelectronics: Abstr. 8th Sci. Techn. Conf., VNIIFTRI, Moscow (2006), pp. 40–42.
J. Ascroft, “Developments on coaxial power standards at NPL,” IEEE Trans. Instrum. Meas., IM-48, No. 4, 647–649 (1999).
D. Janik, “Microcalorimeter for 3.5 mm 50 Ω coaxial transmission line,” Digest CPEM-96, Braunschweig, Germany (1996), pp. 456–457.
J. W. Allen et al., “NIST microwave power standard in waveguide,” NIST Tech. Note 1511 (Feb. 1999).
T. R. Panteleeva and V. A. Perepelkin, “Prototype apparatus for measuring the modulus and phase of the microwave reflection coefficient,” Zakonodat. Prikl. Metrol., No. 5, 20–22 (1993).
A. I. Mekhannikov and V. A. Perepelkin, “Microwave multimeter and its operating algorithms,” Izmer. Tekhn., No. 3, 52–55 (1994); Measur. Techn., 37, No. 3, 330–337 (1994).
V. A. Perepelkin, “Microwave multimeter based on a four probe microwave transmitted power transducer,” ibid., 57–60; ibid., 341–346.
MI 3057, Method for Measuring the Modulus of the Effective Reflection Coefficient at the Outlet from Transmitted-Power Microwave Wattmeters by Combined Measurements.
I. P. Chirkov, “Methods of Reducing the Error in Transferring the Unit of Microwave Power in Coaxial Channels,” this issue of the journal, pp. 83–89.
“Power in 50Ω coaxial lines, frequency: 50 MHz to 26 GHz,” Measur. Techn. and Results Final Report, www.bipm.org/utils/common/pdf/final_reports/EM/RF/K10/CCEM.RF-K10.CL.pdf, accessed Aug. 1, 2011.
“CIPM key comparison CCEM.RF-K25.W RF power from 33 to 50 GHz in waveguide,” Techn. Protocol, http://kcdb.bipm.org/appendixb/appbresults/CCEM.RF-K25.W/CCEM.RF-K25.W_Technical_Protocol.pdf, accessed Aug. 1, 2011.
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Izmeritel’naya Tekhnika, No. 1, pp. 7–10, January, 2012.
Rights and permissions
About this article
Cite this article
Perepelkin, V.A., Semenov, V.A., Chirkov, I.P. et al. National primary standard for the unit of power of electromagnetic oscillations in waveguides and coaxial lines at frequencies of 0.03–37.5 GHz. Meas Tech 55, 8–12 (2012). https://doi.org/10.1007/s11018-012-9908-z
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11018-012-9908-z