Standard ferromagnetic samples, which optimize the adjustment of magnetic measuring flaw detectors are developed, which enable the dependence of the result of monitoring wear on the grade of the steel of cables and the operating conditions to be reduced.
Similar content being viewed by others
References
RD 03-348-00, Procedural Instructions for the Magnetic Flaw Detection of Steel Cables.
RD ROSEK 012-97, Steel Cables. Monitoring and Standards of Quality Inspection.
Procedural Instructions for the Magnetic Flaw Detection of the Steel Cables of Elevators, SP Intron Plyus, Moscow (2000).
V. V. Klyuev (ed.), Instruments for the Nondestructive Testing of Materials and Articles:A Reference Book [in Russian], Mashinostroenie, Moscow (1976).
Instruments for Measuring the Wear of Steel Cables. Intros MDK21, NPF Intron Plyus, Moscow (1997).
State Standard GOST 8.315-97, Standard Samples of the Composition and Properties of Substances and Materials. Basic Definitions.
V. G. Sorokin (ed.), Grades of Steels and Alloys [in Russian], Mashinostroenie, Moscow (1989).
S. V. Vonsovskii and Ya. S. Shur, Ferromagnetism [in Russian], Gostekhizdat, Moscow (1948).
I. K. Kikoin (ed.), Tables of Physical Quantities. A Reference Book [in Russian], Atomizdat, Moscow (1976).
V. I. Chechernikov, Magnetic Measurements [in Russian], MGU, Moscow (1963).
R. I. Yanus, Magnetic Flaw Detection [in Russian], Gostekhizdat, Moscow, Leningrad (1946).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from Izmeritel’naya Tekhnika, No. 5, pp. 54–57, May, 2010.
Rights and permissions
About this article
Cite this article
Pudov, V.I., Sobolev, A.S. & Voronina, S.V. Measurement of the physical parameters of ferromagnetic samples – simulators of steel cables. Meas Tech 53, 542–548 (2010). https://doi.org/10.1007/s11018-010-9540-8
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11018-010-9540-8