The principle of time division of the channels for converting passive quantities and methods of achieving it are described. Measuring circuits of capacitive and inductive sensors, which employ switching methods and phase and polyharmonic division of the channels are considered. Each of these circuits enables the error due to the finite value of the amplifier gain to be eliminated, and ensures that the conversion of the informative parameter of the sensor is invariant to the cable parameters.
Similar content being viewed by others
References
V. P. Arbuzov, Structural Methods of Increasing the Accuracy of the Measuring Circuits of Capacitive and Inductive Sensors [in Russian], Inf.-Izd. Tsentr Penz. Gos. Univ., Penza (2008).
V. P. Arbuzov, Izmer. Tekhn., No. 7, 40 (2007); Measur. Techn., 50, No. 7, 752 (2007).
V. P. Arbuzov, Prib. Sistemy Upravl., No. 7, 29 (1996).
V. P. Arbuzov, Datch. Sistemy, No. 5, 27 (1999).
A. I. Martyashin et al., Principles of the Invariant Conversion of the Parameters of Electric Circuits [in Russian], Energoatomizdat, Moscow (1990).
Author information
Authors and Affiliations
Corresponding author
Additional information
Translated from izmeritel’naya Tekhnika, No. 5, pp. 57–61, May, 2009.
Rights and permissions
About this article
Cite this article
Arbuzov, V.P. Time division of the channels of the measuring circuits of capacitive and inductive sensors. Meas Tech 52, 528–535 (2009). https://doi.org/10.1007/s11018-009-9294-3
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11018-009-9294-3