Abstract

The piezoelectric sensor in the structural health monitoring (SHM) system may be debonded due to complex service environment. However, there are little attention on the debonding behavior of piezoelectric element, which could affect the reliability of the monitoring network. This paper considers the effect of left and right debonding of sensor on receiving signal with different debonding length (2, 4, 6 and 8 mm, respectively) and debonding directions (which are 90°, 180° and 270°, respectively). A finite element model was established to simulate the interface debonding between piezo disc and Aluminium matrix, and both an experimental investigation using a real Aluminium plate is made to further comparison with the simulation results. The characteristic parameters including the amplitude and phase of time domain receiving Lamb wave signals were extracted. The simulation results show the voltage distributions of piezoelectric sensor under different debonding length and direction. In addition, receiving signal indicates that there is not a monotonic downward trend of signal amplitude with the increase of right debonding length of the sensor. And when the wave propagation direction is parallel to the sensor debonding direction (180°), the signal amplitude of the sensor is greater than that perpendicular to the debonding direction (90° and 270°).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19

Similar content being viewed by others

Data availability statement

The data that support the findings of this study are available from the corresponding author or author initials, upon reasonable request.

References

  • Blackshire, J. L., Cooney, A.T. Characterization of bonded piezoelectric sensor performance and durability in simulated aircraft environments. AIP Conference Proceedings. American Institute of Physics, 2006, 820(1): 1694–1701.

  • Blackshire, J. L., Giurgiutiu, V., Cooney, A., et al. Characterization of sensor performance and durability for structural health monitoring systems. Advanced Sensor Technologies for Nondestructive Evaluation and Structural Health Monitoring. SPIE, 2005, 5770: 66–75.

  • Cai R., C., Jin Y., B., Li Y., et al. Exceptional Points and Skin Modes in Non-Hermitian Metabeams. Physical Review Applied, 2022, 18(1): 014067.

  • Farrar, C.R., Worden, K.: An introduction to structural health monitoring. Philosophical Transactions of the Royal Society a: Mathematical, Physical and Engineering Sciences 2007(365), 303–315 (1851)

    Google Scholar 

  • Giurgiutiu, V.: Tuned Lamb wave excited and detection with piezoelectric wafer active sensors for structural health monitoring. J. Intell. Mater. Syst. Struct. 16(4), 291–305 (2005)

    Article  Google Scholar 

  • Giurgiutiu, V., et al.: Smart sensors for monitoring crack growth under fatigue loading conditions. Smart Struct. Syst. 2(2), 101–113 (2006)

    Article  Google Scholar 

  • Giurgiutiu, V.: Structural Health Monitoring: With Piezoelectric Wafer Active Sensors. Academic Press, Cambridge, MA, USA (2007)

    Google Scholar 

  • Giurgiutiu, V., Postolache, C., Tudose, M.: Radiation, temperature, and vacuum effects on piezoelectric wafer active sensors. Smart Mater. Struct. 25(3), 035024 (2016)

    Article  Google Scholar 

  • Gupta, V., Sharma, M., Thakur, N., et al.: Active vibration control of a smart plate using a piezoelectric sensor–actuator pair at elevated temperatures. Smart Mater. Struct. 20(10), 105023 (2011)

    Article  Google Scholar 

  • Ha, S., Chang, F.K.: Optimizing a spectral element for modeling PZT-induced Lamb wave propagation in thin plates. Smart Mater. Struct. 19(1), 015015 (2009)

    Article  Google Scholar 

  • Jin Y., B., Zhong W., X., Cai R., C., et al. Non-Hermitian skin effect in a phononic beam based on piezoelectric feedback control. Applied Physics Letters, 2022, 121(2): 022202.

  • Karayannis, C.G., Voutetaki, M.E., Chalioris, C.E., et al.: Detection of flexural damage stages for RC beams using Piezoelectric sensors (PZT). Smart Struct. Syst. 15(4), 997–1018 (2015)

    Article  Google Scholar 

  • Kessler, S.S., Spearing, S.M., Soutis, C.: Damage detection in composite materials using Lamb wave methods. Smart Mater. Struct. 11(2), 269 (2002)

    Article  Google Scholar 

  • Khan, A., Kim, H.S.: Investigation of the dynamic effects of partial sensor debonding in smart composite laminates. International Society for Optics and Photonics, Spie Smart Structures & Materials + Nondestructive Evaluation & Health Monitoring (2016)

    Google Scholar 

  • Khan, A., Kim, H.S.: Assessment of sensor debonding failure in system identification of smart composite laminates. NDT and E Int. 93, 24–33 (2017)

    Article  Google Scholar 

  • Kuhn J. D., Swenson E. D., Soni S. R. PZT Behavior in cyclic strain environments. Proceedings of SPIE - The International Society for Optical Engineering. 2009:7295.

  • Lamb, H.: On waves in an elastic plate. Proc. r. Soc. 93, 114–128 (1917)

    MATH  Google Scholar 

  • Lanzara, G., Yoon, Y., Kim, Y., et al.: Influence of interface degradation on the performance of piezoelectric actuators. J. Intell. Mater. Syst. Struct. 20(14), 1699–1710 (2009)

    Article  Google Scholar 

  • Liang, R., Wang, Q.M.: High sensitivity piezoelectric sensors using flexible PZT thick-film for shock tube pressure testing. Sens. Actuators, A 235, 317–327 (2015)

    Article  Google Scholar 

  • Liu, X., Xu, Y., Wang, X., et al.: Effect of Adhesive and Its Aging on the Performance of Piezoelectric Sensors in Structural Health Monitoring Systems. Metals. 10(10), 1342 (2020)

    Article  Google Scholar 

  • Lopez, M.R., Sergiyenko, O.Y., Tyrsa, V.V., et al.: Optoelectronic method for structural health monitoring. Struct. Health Monit. 9(2), 105–120 (2010)

    Article  Google Scholar 

  • Monkhouse, R.S.C., Wilcox, P.D., Cawley, P.: Flexible interdigital PVDF transducers for the generation of Lamb waves in structures. Ultrasonics 35, 489–498 (1997)

    Article  Google Scholar 

  • Park, G., Farrar, C.R., Scalea, F.L.D., et al.: Performance assessment and validation of piezoelectric active-sensors in structural health monitoring. Smart Mater. Struct. 15(6), 6–2431 (2006)

    Article  Google Scholar 

  • Petrie E. M. Handbook of Adhesives and Sealants. McGraw-Hill, 2006.

  • Qing, X.P., Chan, H.L., Beard, S.J., et al.: Effect of adhesive on the performance of piezoelectric elements used to monitor structural health. Int. J. Adhes. Adhes. 26(8), 622–628 (2006)

    Article  Google Scholar 

  • Rabczuk T., Belytschko T. Cracking particles: A simplified meshfree method for arbitrary evolving cracks. 6th World Congress on Computational Mechanics. 2004.

  • Rabczuk, T., Zi, G., Bordas, S., et al.: A simple and robust three-dimensional cracking-particle method without enrichment. Comput. Methods Appl. Mech. Eng. 199(37–40), 2437–2455 (2010)

    Article  MATH  Google Scholar 

  • Rugina, C., Enciu, D., Tudose, M.: Numerical and experimental study of circular disc electromechanical impedance spectroscopy signature changes due to structural damage and sensor degradation. Struct. Health Monit. 14(6), 663–681 (2015)

    Article  Google Scholar 

  • Saravanan, T.J., Chauhan, S.S.: Study on pre-damage diagnosis and analysis of adhesively bonded smart PZT sensors using EMI technique. Measurement 188, 110411 (2022)

    Article  Google Scholar 

  • Sun, D., Tong, L., Atluri, S.N.: Effects of piezoelectric sensor/actuator debonding on vibration control of smart beams. Int. J. Solids Struct. 38(50–51), 9033–9051 (2001)

    Article  MATH  Google Scholar 

  • Tinoco, H.A., Serpa, A.L.: Voltage relations for debonding detection of piezoelectric sensors with segmented electrode[J]. Mech. Syst. Signal Process. 31, 258–267 (2012)

    Article  Google Scholar 

  • Tressler, J.F., Alkoy, S., Newnham, R.E.: Piezoelectric sensors and sensor materials. J. Electroceram. 2(4), 257–272 (1998)

    Article  Google Scholar 

  • Tua, P.S., Quek, S.T., Wang, Q., Detection of crack in thin cylindrical pipes using piezo-actuated Lamb waves. Smart Structures and Materials,: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems. International Society for Optics and Photonics. 2005(5765), 820–831 (2005)

    Google Scholar 

  • Wang, X., Yu, R.P., Zhang, Q.C., et al.: Dynamic response of clamped sandwich beams with fluid-fillied corrugated cores. Int. J. Impact Eng 139, 103533 (2020)

    Article  Google Scholar 

  • Wang X., He C., Yue Z., et al. Shock resistance of elastomer-strengthened metallic corrugated core sandwich panels. Composites, Part B. Engineering, 2022: 237.

  • Wilcox, P.D., Lowe, M.J.S., Cawley, P.: Mode and transducer selection for song range Lamb wave inspection. J. Intell. Mater. Syst. Struct. 12(8), 553–565 (2001)

    Article  Google Scholar 

  • Yan S., Wu J., Sun W., et al. Development and Application of Structural Health Monitoring System Based on Piezoelectric Sensors. International Journal of Distributed Sensor Networks. 2013:1–12.

  • Yu, R.P., Li, X., Yue, Z.S., et al.: Stress state sensitivity for plastic flow and ductile fracture of L907A low-alloy marine steel: From tension to shear. Mater. Sci. Eng., A 835, 142689 (2022)

    Article  Google Scholar 

  • Zhang, Y., Mang, H.A.: Global cracking elements: a novel tool for Galerkin-based approaches simulating quasi-brittle fracture. Int. J. Numer. Meth. Eng. 1908, 06268 (2019)

    Google Scholar 

  • Zhang, Y., Zhuang, X.: Cracking elements: A self-propagating Strong Discontinuity embedded Approach for quasi-brittle fracture. Finite Elem. Anal. Des. 144, 84–100 (2018)

    Article  MathSciNet  Google Scholar 

  • Zhang, Y., Zhuang, X.: Cracking elements method for dynamic brittle fracture. Theoret. Appl. Fract. Mech. 102, 1–9 (2019)

    Article  Google Scholar 

  • Zhang Y., Lackner R., Zeiml m., et al. Strong discontinuity embedded approach with standard SOS formulation: Element formulation, energy-based crack-tracking strategy, and validations. Computer Methods in Applied Mechanics and Engineering. 2015, 287: 335–366.

  • Zhang, Y., Gao, Z., Li, Y., et al.: On the crack opening and energy dissipation in a continuum based disconnected crack model. Finite Elem. Anal. Des. 170, 103333 (2019)

    Article  MathSciNet  Google Scholar 

  • Zhang Y., Huang J., G., Yuan Y., et al. Cracking elements method with a dissipation-based arc-length approach. Finite Elements in Analysis and Design. 2021a, 195: 103573.

  • Zhang, Y., Yang, X.Q., Wang, X.Y., et al.: A micropolar peridynamic model with non-uniform horizon for static damage of solids considering different nonlocal enhancements. Theoret. Appl. Fract. Mech. 113, 102930 (2021b)

    Article  Google Scholar 

  • Zhang, Y., Gao, Z., Wang, X., et al.: Image Representations of Numerical Simulations for Training Neural Networks. Comput. Model. Eng. Sci. 2, 13 (2023)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Weifang Zhang.

Ethics declarations

Conflict of interest

We would like to submit the enclosed manuscript entitled “Effect of Piezoelectric Sensor Debonding Failure on Structural Health Monitoring System Based on Lamb Wave Signals”, which we wish to be considered for publication in International Journal of Mechanics and Materials in Design. No conflict of interest exits in the submission of this manuscript, and manuscript is approved by all authors for publication. I would like to declare on behalf of my co-authors that the work described was original research that has not been published previously, and not under consideration for publication elsewhere, in whole or in part. All the authors listed have approved the manuscript that is enclosed.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Liu, X., Xu, Y., Li, N. et al. Effect of piezoelectric sensor debonding failure on structural health monitoring system based on lamb wave signals. Int J Mech Mater Des 19, 285–298 (2023). https://doi.org/10.1007/s10999-022-09627-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10999-022-09627-4

Keywords

Navigation