Abstract
Impedance spectroscopy and application of Lamb waves are attractive methods for permanent monitoring of integrity in Structural Health Monitoring (SHM). Investigations of CFRP structures (Carbon Fibre Reinforced Polymers) with embedded or attached piezoceramic elements are presented for both methods. Examples regard impact damage detection as well as estimation of influencing factors (e.g. degradation of contacts or piezoceramic) and important characteristics (e.g. generation, velocity and attenuation of Lamb waves).
Similar content being viewed by others
References
Blackshire, J.L., Martin, S.A., Na, J.K.: The influence of bond material type and quality on damage detection for surface-bonded piezoelectric sensors. In: Proceedings of the 6th International Workshop on Structural Health Monitoring, Stanford, pp. 203–210 (2007)
Boller, C., Biemanns, C., Staszewski, W.J., Worden, K., Tomlinson, G.R.: Structural damage monitoring based on an actuator-sensor system. In: Wereley, N.M. (ed.) SPIE Conference on ‘Smart Structures and Materials 1999: Smart Structures and Integrated Systems’, Newport Beach, CA, USA, March 1999. SPIE Proceeding, vol. 3668, pp. 285–294 (1999)
Boller, C., Chang, F.-K., Fujino, Y.: Encyclopedia of Structural Health Monitoring. Wiley, Chichester (2009)
Cawley, P., Lowe, M.J.S., Alleyne, D.N., Pavlakovic, B., Wilcox, P.: Practical long range guided wave inspection—applications to pipes and rail. Mater. Evaluation 61, 66–74 (2003)
Chang, F.-K.: Composite structures with built-in diagnostic. ICCM12, Paris, paper 799 (1999)
Chimenti, D.E.: Guided waves in plates and their use in materials characterization. Appl. Mech. Rev. 50(5), 247–284 (1997)
Clarke, T., Cawley, P.: Monitoring of complex structures using guided waves. In: Proceedings of the Fourth European Workshop on Structural Health Monitoring held at Krakow, Poland, July 2–4, pp. 672–679 (2008)
Diamanti, K., Hodgkinson, J.M., Soutis, C.: Detection of low-velocity impact damage in composite plates using Lamb waves. Struct. Health Monit. 3(1), 33–41 (2004)
Diligent, O., Grahn, T., Boström, A., Cawley, P., Lowe, M.J.S.: The low-frequency reflection and scattering of the S0 Lamb mode from a circular through-thickness hole in a plate: finite element, analytical and experimental studies. J. Acoust. Soc. Am. 112(6), 2589–2601 (2002)
Eckstein, B., Fritzen, C.-P., Bach, M.: Advancements in self-diagnosis of bonded piezoelectric transducers. In: Proceedings of the Fourth European Workshop on Structural Health Monitoring held at Krakow, Poland, July 2–4, pp. 430–437 (2008)
Finlayson, R.D., Friesel, M.A., Carlos, M.R., Miller, R.K., Godinez, V.: Acoustic emission structural health management systems (AE-SHMS). In: Mal, A.K. (ed.) SPIE Conference on ‘Nondestructive Evaluation of Aging Aircraft, Airports, and Aerospace Hardware IV’, Newport Beach, CA, USA, March 1999. SPIE Proceeding, vol. 3994, pp. 128–137 (2000)
Fromme, P.: Structural health monitoring of stiffened plates using guided ultrasonic waves. Review of progress in quantitative nondestructive evaluation. In: Proceedings of the 35th Annual Review of Progress in Quantitative Nondestructive Evaluation. AIP Conference Proceedings, vol. 1096, pp. 998–1005 (2009)
Giurgiutiu, V.: Structural Health Monitoring with Piezoelectric Wafer Active Sensors. Academic Press, London (2008). ISBN 9780120887606
Hillger, W., Pfeiffer, U.: Structural health monitoring using Lamb waves. In: 9th European NDT Conference, ECNDT 2006, Berlin, paper Th 1.7.2 (2006)
Ihn, J.-B., Chang, F.-K.: Detection and monitoring of hidden fatigue crack growth using a built-in piezoelectric sensor/actuator network: I. Diagnostics. Smart Mater. Struct. 13, 609–620 (2004)
Kessler, S.S., Spearing, S.M., Soutis, C.: Damage detection in composite materials using Lamb wave methods. Smart Mater. Struct. 11(2), 269–278 (2002)
Köhler, B.: Dispersion relations in plate structures studied with a scanning laser vibrometer. In: 9th European NDT Conference, ECNDT 2006, Berlin, paper Mo.2.1.4 (2006)
Köhler, B., Schubert, F., Barth, M., Frankenstein, B.: Selective excitation and detection of Lamb waves for SHM applications. In: Proceedings of the Fourth European Workshop on Structural Health Monitoring held at Krakow, Poland, July 2–4, pp. 706–714 (2008)
Kudela, P., Ostachowicz, W.: Lamb-wave based damage detection in composite structures:potentials and limitations. In: Proceedings of the Fourth European Workshop on Structural Health Monitoring held at Krakow, Poland, July 2–4, pp. 488–495 (2008)
Lemistre, M., Gouyon, R., Kaczmarek, H., Balageas, D.: Damage detection in composite plates using wavelet transform processing on lamb wave signals. In: Chang, F.-K. (ed.) Proceedings of the 2nd International Workshop on Structural Health Monitoring, pp. 861–870. Technomic Publishing company, Lancaster (1999)
Liang, C., Sun, F.P., Rogers, C.A.: Coupled electro-mechanical analysis of adaptive material systems–determination of the actuator power consumption and system energy transfer. J. Int. Mater. Syst. Struct. 5, 12–20 (1994)
Macdonald, J.R.: Impedance Spectroscopy. Wiley, New York (1987)
Mal, A.: Elastic waves from localized sources in composite laminates. Int. J. Solids Struct. 39(21–22), 5481–5494 (2002)
Nixdorf, K., Busse, G.: Electrical impedance spectroscopy for cure monitoring and damage detection in model adaptive components. In: ADAMES, Proceedings of the Euromech 373 Colloquium Modelling and Control of Adaptive Mechanical Structures, Magdeburg, pp. 57–66 (1998)
Ng, C.T., Veidt, M.: A Lamb-wave-based technique for damage detection in composite laminates. Smart Mater. Struct. 18, 074006 (2009)
Osmont, D., Dupont, M., Lemistre, M., Gouyon, R., Kaczmarek, H., Balageas, D.: Piezoelectric based health monitoring systems for composite plates. In: Ohayon, R., Bernadou, M. (eds.) 10th International Conference on Adaptive Structures and Technologies (ICAST’99), pp. 601–608. Technomic Publishing Company, Lancaster (1999)
Pardo de Vera, C., Guemes, J.A.: Embedded self-sensing piezoelectric for damage detection. J. Intell. Mater. Syst. Struct. 9(11), 876–882 (1999)
Park, G., Cudney, H., Inman, D.J.: Impedance-based health monitoring of civil infrastructures. ASCE/J. Infrastructure Syst. 6(Nr.4), 153–160 (2000)
Park, G., Sohn, H., Farrar, C.R., Inman, D.J.: Overview of piezoelectric impedance based health monitoring and path forward. Shock Vib. Dig. 35(6), 451–463 (2003)
Park, S., Park, G., Yun, C.-B., Farrar, C.R.: Sensor self-diagnosis using a modified impedance model for active sensing-based structural health monitoring. Struct. Health Monit. 8, 71–82 (2009)
Raghavan, A., Cesnik, C.E.S.: Review of guided-wave structural health monitoring. Shock Vib. Dig. 39, 91–114 (2007)
Rajagopalan, J., Balasubramaniam, B., Krishnamurthy, C.V.: A phase reconstruction algorithm for Lamb wave based structural health monitoring of anisotropic multilayered composite plates. J. Acoust. Soc. Am. 119(2), 872–878 (2006)
Rose, J.L.: Ultrasonic Waves in Solid Media. Cambridge University Press, Cambridge (2004). ISBN 0-521-54889-6
Seydel, R.E., Chang, F.-K.: Implementation of a real-time impact identification technique for stiffened composite panels. Structural health monitoring 2000. In: Chang, F.-K. (ed.) Proceedings of the 2nd International Workshop on Structural Health Monitoring, pp. 225–233. Technomic Publishing Company, Lancaster (1999)
Staszewski, W.J., Lee, B., Mallet, K., Scarpa, F.: Structural health monitoring using scanning laser vibrometry: I. Lamb wave sensing. Smart Mater. Struct. 14(2), 251–260 (2004)
Su, Z., Ye, L., Lu, Y.: Guided Lamb waves for identification of damage in composite structures: a review. J. Sound Vib. 295, 753–780 (2006)
Sun, F.P., Chaudhry, Z., Liang, C., Rogers, C.A.: Truss structure integrity identification using PZT sensor-actuator. In: Second International Conference on Intelligent Materials, pp. 1210–1221. Technomic Publishing Company, Lancaster (1994)
Viktorov, I.A.: Rayleigh and Lamb waves. Plenum Press, New York (1967)
Xing, K., Fritzen, C.-P.: Monitoring of growing fatigue damage using the E/M impedance method. Key Eng. Mater. 347, 153–158 (2007)
Xu, P.-C., Lindenschmidt, K.-E., Meguid, S.A.: A new high-frequency analysis of coatings using leaky Lamb waves. J. Acoust. Soc. Am. 94, 2954 (1993)
Zagrai, A.N., Giurgiutiu, V.: Electro-mechanical impedance method for crack detection in thin plates. J. Intell. Mater. Syst. Struct. 12, 709–718 (2001)
Acknowledgements
The support of Deutsche Forschungsgemeinschaft (MO 553/9-1) is thankfully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pohl, J., Mook, G. SHM of CFRP-structures with impedance spectroscopy and Lamb waves. Int J Mech Mater Des 6, 53–62 (2010). https://doi.org/10.1007/s10999-010-9120-8