Abstract
In this study, the effect of using twisted tapes with various geometries in both tubes of a double-pipe heat exchanger is numerically investigated. The twisted tapes are inserted in both sides of double-pipe heat exchanger to improve the heat transfer where the fluid is water in both sides. The influence of geometrical parameters including the number of twisted tape and creating hollow on twisted tape with different aspect ratios is investigated numerically. The obtained results are analyzed by calculating the outlet temperature of both sides, pressure drop, Nusselt number, and coefficient of performance. Numerical simulations are performed by a commercial CFD code, ANSYS FLUENT 18.2. The results indicate that increasing the number of twisted tape from one-fin to four-fin leads to an increase in the Nusselt number 3.1%, pressure drop 64%, and coefficient of performance 63.9%. Eventually, based on outcomes, four-fin twisted tapes provided better coefficient of performance. In the second part of the study, the effect of creating hollow on the four-fin twisted tape with different aspect ratios (AR = W/H) is studied. Three different aspect ratios including 2.25, 1, and 0.44 are considered. The results show that creating the hollows with AR = 1 on the twisted tape leads to better coefficient of performance.
Similar content being viewed by others
References
Berger SA, Talbot L, Yao LS. Flow in curved pipes. Annu Rev Fluid Mech. 1983;15(1):461–512.
Eustice J. Experiments on stream-line motion in curved pipes. Proc R Soc Lond Ser A. 1911;85(576):119–31.
Kumar A, Prasad BN. Investigation of twisted tape inserted solar water heaters—heat transfer, friction factor and thermal performance results. Renew Energy. 2000;19(3):379–98.
Jaisankar S, Radhakrishnan TK, Sheeba KN. Experimental studies on heat transfer and friction factor characteristics of thermosyphon solar water heater system fitted with spacer at the trailing edge of twisted tapes. Appl Therm Eng. 2009;29(5–6):1224–31.
Eiamsa-Ard S, Yongsiri K, Nanan K, Thianpong C. Heat transfer augmentation by helically twisted tapes as swirl and turbulence promoters. Chem Eng Process. 2012;60:42–8.
Eiamsa-Ard S, Wongcharee K, Eiamsa-Ard P, Thianpong C. Thermohydraulic investigation of turbulent flow through a round tube equipped with twisted tapes consisting of centre wings and alternate-axes. Exp Thermal Fluid Sci. 2010;34(8):1151–61.
Eiamsa-Ard S, Promvonge P. Performance assessment in a heat exchanger tube with alternate clockwise and counter-clockwise twisted-tape inserts. Int J Heat Mass Transf. 2010;53(7–8):1364–72.
Eiamsa-Ard S, Thianpong C, Eiamsa-Ard P. Turbulent heat transfer enhancement by counter/co-swirling flow in a tube fitted with twin twisted tapes. Exp Thermal Fluid Sci. 2010;34(1):53–62.
Thianpong C, Eiamsa-Ard P, Promvonge P, Eiamsa-Ard S. Effect of perforated twisted-tapes with parallel wings on heat transfer enhancement in a heat exchanger tube. Energy Procedia. 2012;14:1117–23.
Eiamsa-Ard S, Promvonge P. Thermal characteristics in round tube fitted with serrated twisted tape. Appl Therm Eng. 2010;30(13):1673–82.
Murugesan P, Mayilsamy K, Suresh S. Turbulent heat transfer and pressure drop in tube fitted with square-cut twisted tape. Chin J Chem Eng. 2010;18(4):609–17.
Promvonge P. Thermal augmentation in circular tube with twisted tape and wire coil turbulators. Energy Convers Manag. 2008;49(11):2949–55.
Darzi AR, Farhadi M, Sedighi K, Aallahyari S, Delavar MA. Turbulent heat transfer of Al2O3–water nanofluid inside helically corrugated tubes: numerical study. Int Commun Heat Mass Transf. 2013;41:68–75.
Shaji K. Numerical analysis on a double pipe heat exchanger with twisted tape induced swirl flow on both sides. Procedia Technol. 2016;24:436–43.
Wongcharee K, Eiamsa-Ard S. Heat transfer enhancement by using CuO/water nanofluid in corrugated tube equipped with twisted tape. Int Commun Heat Mass Transf. 2012;39(2):251–7.
Menter FR. Two-equation eddy-viscosity turbulence models for engineering applications. AIAA J. 1994;32(8):1598–605.
Wilcox David C. Turbulence modeling for CFD, vol. 2. La Canada: DCW industries; 1998.
Baragh S, Shokouhmand H, Ajarostaghi SS, Nikian M. An experimental investigation on forced convection heat transfer of single-phase flow in a channel with different arrangements of porous media. Int J Therm Sci. 2018;1(134):370–9.
Shirzad M, Ajarostaghi SS, Delavar MA, Sedighi K. Improve the thermal performance of the pillow plate heat exchanger by using nanofluid: numerical simulation. Adv Powder Technol. 2019;30(7):1356–65.
Baragh S, Shokouhmand H, Ajarostaghi SS. Experiments on mist flow and heat transfer in a tube fitted with porous media. Int J Therm Sci. 2019;1(137):388–98.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Noorbakhsh, M., Zaboli, M. & Mousavi Ajarostaghi, S.S. Numerical evaluation of the effect of using twisted tapes as turbulator with various geometries in both sides of a double-pipe heat exchanger. J Therm Anal Calorim 140, 1341–1353 (2020). https://doi.org/10.1007/s10973-019-08509-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10973-019-08509-w