Skip to main content
Log in

Precious walls built in indoor environments inspected numerically and experimentally within long-wave infrared (LWIR) and radio regions

  • Published:
Journal of Thermal Analysis and Calorimetry Aims and scope Submit manuscript

Abstract

A thermographic non-destructive inspection conducted during the winter season on precious walls confined to an indoor environment (Baiocco room, L’Aquila, Italy) is illustrated herein. The use of a heat conveyor ad hoc selected has produced a particular benefit in terms of defect detection after the application of advanced algorithms because the thermal stimulus coming from an air heater hit the finishing layer under a laminar flow regime. Thermocouples registered both the heat-up and cool-down phases to confirm the numerical simulations conducted via Comsol Multiphysics® software. The results obtained by applying the principal component thermography (PCT) technique to raw data registered in the time domain were a priori studied through thermographic simulations. Defects were modelled on the basis of results already shown in a previous work centred on the Baiocco room, too. A comparison between the results obtained from PCT and the innovative sparse principal component thermography (SPCT) technique was also added to the discussion. The SPCT results show their benefits above all when they are supplemented with ground-penetrating radar results. The experimental analyses were conducted on a multi-layer wall called thereafter rectangular portal, in which the instant thermal conductance was experimentally measured. Subsurface cracks were detected using a long heating-up phase. This procedure is preferred by the Monuments and Fine Arts Department with respect to the use of flash lamps. Indeed, short energy pulses should be avoided on finishing layers having low emissivity values because producing spurious reflections affecting the thermographic results. A discussion on this point is also provided. On the basis of the data analysis, it is possible to say that the thermal waves should arrive at the interface between the masonry and its top layer in order to obtain a clear thermal map of the defects present at different depths. As shown, this goal can be realized through a smart solution based on: (a) the inverse knowledge of the aedicula via thermal analyses, (b) the best mesh to be selected for the numerical model, and (c) the optimal type of thermal stress to be delivered to the object under inspection.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26

Similar content being viewed by others

References

  1. Perilli S, Sfarra S, Ambrosini D, Paoletti D, Mai S, Scozzafava M, Yao Y. Combined experimental and computational approach for defect detection in precious walls built in indoor environments. Int J Therm Sci. 2018;129:29–46.

    Article  Google Scholar 

  2. Perilli S, Regi M, Sfarra S, Nardi I. Comparative analysis of heat transfer for an advanced composite material used as insulation in the building field by means of Comsol Multiphysics® and Matlab® computer programs. Romanian J Mater. 2016;46(2):185–95.

    CAS  Google Scholar 

  3. Zhang H, Fernandes H, Djupkep Dizeu FB, Hassler U, Fleuret J, Genest M, Ibarra-Castanedo C, Robitaille F, Joncas S, Maldague X. Pulsed micro-laser line thermography on submillimeter porosity in carbon fiber reinforced polymer composites: experimental and numerical analyses for the capability of detection. Appl Opt. 2016;55(34):D1–10.

    Article  CAS  PubMed  Google Scholar 

  4. Yan Z, Chen C-Y, Luo L, Yao Y. Stable principal component pursuit-based thermographic data analysis for defect detection in polymer composites. J Process Control. 2017;49:36–44.

    Article  CAS  Google Scholar 

  5. Perilli S, Sfarra S, Guerrini M, Bisegna F, Ambrosini D. The thermophysical behaviour of cork supports doped with an innovative thermal insulation and protective coating: a numerical analysis based on in situ experimental data. Energy Build. 2018;159:508–28.

    Article  Google Scholar 

  6. Ranalli D, Scozzafava M, Tallini M. Ground penetrating radar investigations for the restoration of historic buildings: the case study of the Collemaggio Basilica (L’Aquila, Italy). J Cult Herit. 2004;5(1):91–9.

    Article  Google Scholar 

  7. Starnes MA, Carino NJ, Kausel EA. Preliminary thermography studies for quality control of concrete structures strengthened with fiber-reinforced polymer composites. J Mater Civ Eng. 2003;15(3):226–73.

    Article  CAS  Google Scholar 

  8. Binda L, Cardani G, Zanzi L. Nondestructive testing evaluation of drying process in flooded full-scale masonry walls. J Perform Constr Facil. 2010;24(5):473–83.

    Article  Google Scholar 

  9. Ueno K, Straube J, Van Straaten R. Field monitoring and simulation of a historic mass masonry building retrofitted with interior insulation. In: Proceedings of the 12th international conference on thermal performance of the exterior envelopes of whole buildings, USA, December 2013, code 115881.

  10. Solla M, Lagüela S, Riveiro B, Lorenzo H. Non-destructive testing for the analysis of moisture in the masonry arch bridge of Lubians (Spain). Struct Control Health Monit. 2013;20(11):1366–76.

    Google Scholar 

  11. De Freitas SS, De Freitas VP, Barreira E. Detection of facade plaster detachments using infrared thermography—a nondestructive technique. Constr Build Mater. 2014;70:80–7.

    Article  Google Scholar 

  12. Rainieri C, Marra A, Rainieri GM, Gargaro D, Pepe M, Fabbrocino G. Integrated non-destructive assessment of relevant structural elements of an Italian heritage site: the Carthusian monastery of Trisulti. J Phys: Conf Ser. 2015;628(1):012018.

    Google Scholar 

  13. Khan F, Bolhassani M, Kontsos A, Hamid A, Bartoli I. Modeling and experimental implementation of infrared thermography on concrete masonry structures. Infrared Phys Technol. 2015;69:228–37.

    Article  Google Scholar 

  14. Molina-Huelva M, Barrios-Padura A, Fernández-Ans P. Thermal behaviour of reinforced concrete and brick masonry structures. A case study. In: 3rd international conference on structures and architecture, ICSA 2016, 27–29 July 2016, Guimaraes, Portugal, pp 649–658.

  15. Zagowitz A, Renzl A, Hofbauer W, Meyer J, Kuenzel H. Drying behaviour and microbial load after water damage. Struct Surv. 2016;34:24–42.

    Article  Google Scholar 

  16. Sfarra S, Cheilakou E, Theodorakeas P, Paoletti D, Koui M. S.S. Annunziata Church (L’Aquila, Italy) unveiled by non- and micro-destructive testing techniques. Appl Phys A Mater Sci Process. 2017;123(215):1–12.

    CAS  Google Scholar 

  17. Meletti C, Visini F, D’Amico V, Rovida A. Seismic hazard in central Italy and the 2016 Amatrice earthquake. Ann Geophys. 2016;59:1–8.

    Google Scholar 

  18. Bejan A. Convection heat transfer. 4th ed. E-book: Wiley.

  19. http://www.bron.ch/uploads/tx_bronproducts/visatec_download_datasheets_monolights_solo3200b_en.pdf. Accessed 01 Dec 2017.

  20. https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20000093938.pdf. Accessed 01 Dec 2017.

  21. Almond DP, Angioni SL, Pickering SG. Long pulse excitation non-destructive evaluation. NDT&E Int. 2017;87:7–14.

    Article  Google Scholar 

  22. Sfarra S, Theodorakeas P, Ibarra-Castanedo C, Avdelidis NP, Ambrosini D, Cheilakou E, Paoletti D, Koui M, Bendada A, Maldague X. How to retrieve information inherent to old restorations made on frescoes of particular artistic value using infrared vision? Int J Thermophys. 2015;36:3051–70.

    Article  CAS  Google Scholar 

  23. Rajic N. Principal component thermography for flaw contrast enhancement and flaw depth characterisation in composite structures. Compos Struct. 2002;58(4):521–8.

    Article  Google Scholar 

  24. Zou H, Hastie T, Tibshirani R. Sparse principal component analysis. J Comput Graph Stat. 2006;15(2):265–86.

    Article  Google Scholar 

  25. Wold S, Esbensen K, Geladi P. Principal component analysis. Chemometr Intell Lab Syst. 1987;2(1):37–52.

    Article  CAS  Google Scholar 

  26. Yao Y, Sfarra S, Laguela S, Ibarra-Castanedo C, Wu J-Y, Maldague XPV, Ambrosini D. Active thermography testing and data analysis for the state of conservation of panel paintings. Int J Therm Sci. 2018;126:143–51.

    Article  Google Scholar 

  27. Sjöstrand K, Clemmensen LH, Larsen R, Ersbøll B. Spasm: a matlab toolbox for sparse statistical modeling. http://www2.imm.dtu.dk/projects/spasm/ (2012). Accessed Aug 2017.

  28. Beckwith TG, Lewis Buck N. Mechanical measurements. 2nd ed. Addison-Wesley series in mechanics and thermodynamics (1969).

  29. Sfarra S, Bendada A, Ibarra-Castanedo C, Ambrosini D, Paoletti D, Maldague X. Santa Maria di Collemaggio Church (L’Aquila, Italy): historical reconstruction by non-destructive testing techniques. Int J Archit Herit. 2015;9(4):367–90.

    Article  Google Scholar 

  30. Conyers LB, Goodman D. Ground-penetrating radar: an introduction for archaeologists. Walnut Creek, CA: AltaMira Press; 1997.

    Google Scholar 

  31. Sfarra S, Theodorakeas P, Černecký J, Pivarčiová E, Perilli S, Koui M. Inspecting marquetries at different wavelengths: the preliminary numerical approach as aid for a wide-range of non-destructive tests. J Nondestr Eval. 2017;36(6):1–20.

    Google Scholar 

  32. UNI EN ISO 6946:2008.

  33. Nardi I, de Rubeis T, Taddei M, Ambrosini D, Sfarra S. The energy efficiency challenge for a historical building undergone to seismic and energy refurbishment. Energy Procedia. 2017;133:231–42.

    Article  Google Scholar 

  34. Nardi I, Ambrosini D, de Rubeis T, Sfarra S, Perilli S, Pasqualoni G. A comparison between thermographic and flow-meter methods for the evaluation of thermal transmittance of different wall constructions. J Phys: Conf Ser. 2015;655:012007.

    Google Scholar 

  35. RILEM TC 127-MS.D.3 Tests for masonry materials and structures—radar investigation of masonry.

  36. Sfarra S, Regi M. Wavelet analysis applied to thermographic data for the detection of subsuperficial flaws in mosaics. Eur Phys J Appl Phys. 2016;74:1–11.

    Article  CAS  Google Scholar 

  37. Vargas Aparicio JH, Ortega Arroyo L, Mollinedo Ponce de León HR, Ortega Herrera JÁ, Rodríguez Arias YA, Arellano González S, Rodríguez-Romo S, Castaňo VM. Implementation of the boundary element method for detecting defects by transient thermography on aluminium plate. J Therm Anal Calorim. 2016;126:671–9.

    Article  CAS  Google Scholar 

  38. Cobîrzan N, Thalmaier G, Balog A-A, Constantinescu H, Timiş I, Streza M. Thermophysical properties of fired clay bricks with waste ceramics and paper pulp as pore-forming agent. J Therm Anal Calorim. 2018;134:843–51.

    Article  CAS  Google Scholar 

  39. Sfarra S, Perilli S, Paoletti D, Ambrosini D. Ceramics and defects. Infrared thermography and numerical simulations—a wide-ranging view for quantitative analysis. J Therm Anal Calorim. 2016;123:43–62.

    Article  CAS  Google Scholar 

  40. Sfarra S, Regi M, Tortora M, Casieri C, Perilli S, Paoletti D. A multi-technique non-destructive approach for characterizing the state of conservation of ancient bookbindings. J Therm Anal Calorim. 2018;132:1367–87.

    Article  CAS  Google Scholar 

  41. Scudieri F, Mercuri F, Volterri R. Non-invasive analysis of artistic heritage and archaeological findings by time resolved IR thermography. J Therm Anal Calorim. 2001;66:307–14.

    Article  CAS  Google Scholar 

  42. Yao Y, Sfarra S, Ibarra-Castanedo C, You R, Maldague XPV. The multi-dimensional ensemble empirical mode decomposition (MEEMD). An advanced tool for thermographic diagnosis of mosaics. J Therm Anal Calorim. 2017;128:1841–58.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Ms. Sabrina Mai and Mr. Antonio Mignemi (restorers of the MIMARC srl company, Italy) directly involved in restoration of the Baiocco’s room, while Mr. Giovanni Pasqualoni (University of L’Aquila, Italy) for the support during the recording of the thermographic data. The authors are also grateful to the Soprintendenza per i Beni Ambientali, Architettonici, Artistici e Storici per l’Abruzzo (Italy) for allowing the realization of the measurements (data and image recording). Prof. Yao was in part supported by Ministry of Science and Technology, ROC, under Grant Number 105-2628-E-007-013-MY2.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Zhang.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sfarra, S., Yao, Y., Zhang, H. et al. Precious walls built in indoor environments inspected numerically and experimentally within long-wave infrared (LWIR) and radio regions. J Therm Anal Calorim 137, 1083–1111 (2019). https://doi.org/10.1007/s10973-019-08005-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10973-019-08005-1

Keywords

Navigation