Abstract
Results obtained from three round robin tests, performed in 1998, 2000 and 2004, are summarized and presented. Oxidation Induction Time (OITtime) and Oxidation Induction Temperature (OITtemp) on six different grades of polyethylene were measured by DSC. The measured data were collected by Empa and evaluated using a robust statistical method concerning repeatability and reproducibility standard deviation.
The results of the tests indicate that the determination of OITtime is associated with a high degree of uncertainty, especially for low OITtime values. Thus, OITtemp measurements could be a valuable alternative for testing less stabilized or non-stabilized polyolefin in particular. However, OITtemp data reveal that the ability to distinguish between different polymer samples decreases drastically as OITtemp values increase.
Similar content being viewed by others
References
S. L. R. Ellison, M. Roesslein and A. Willams editors, EURACHEM/CITAC Guide, Second Edition, 2000, 7.
J Mandel (1991) Chemometrics and Intelligent Laboratory Systems 11 109 Occurrence Handle10.1016/0169-7439(91)80058-X Occurrence Handle1:CAS:528:DyaK3MXmsFGhtr8%3D
J. R. Pauquet, R. Todesco and W. O. Drake, Limitations and Applications of Oxidation Induction Time (OIT) to Quality Control of Polyolefins, 42nd International Wire and Cable Symposium, 1993.
GW Ehrenstein G Riedel P Trawiel (2003) Praxis der Thermischen Analyse von Kunststoffen Hanser Verlag München
ISO 11357-6 (2002); EN 728 (1997); ASTM D 3895 (1995).
S Wallius (1993) Angew. Makromol. Chem. 212 103 Occurrence Handle1:CAS:528:DyaK2cXjt1Slug%3D%3D
A. T. Riga and G. H. Patterson, Oxidative Behaviour of Materials by Thermal Analytical Techniques, ASTM STP 1326 (1997).
LR Mason AB Reynolds (1997) J. Appl. Polym. Sci. 66 1691 Occurrence Handle10.1002/(SICI)1097-4628(19971128)66:9<1691::AID-APP7>3.0.CO;2-8 Occurrence Handle1:CAS:528:DyaK2sXnt12hsLs%3D
H Gebler (1989) Kunstst 79 9
Z Dobkowski (2005) Polimery 50 213 Occurrence Handle1:CAS:528:DC%2BD2MXjtFakurY%3D
V Dudler DJ Lacey Ch Kröhnke (1996) Polym. Degrad. Stab. 51 115 Occurrence Handle1:CAS:528:DyaK28XitVCjs7g%3D
G Ahlblad P Gijsman B Terselius A Jonsson K Müller (2001) Polym. Degrad. Stab. 73 419
PK Fearon SW Bigger NC Billingham (2004) J. Therm. Anal. Cal. 76 75 Occurrence Handle10.1023/B:JTAN.0000027805.48648.c2
M Schmid S Affolter (2003) Polymer Testing 22 419 Occurrence Handle10.1016/S0142-9418(02)00122-8
DIN 38402-45, Interlaboratory comparisons for proficiency testing of laboratories (2003).
S Affolter M Schmid B Wampfler (1999) Kautsch. Gummi Kunstst 52 519 Occurrence Handle1:CAS:528:DyaK1MXltlajtbs%3D
M Schmid S Affolter A Ritter (2001) Macromol. Mater. Eng. 286 605
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Schmid, M., Ritter, A. & Affolter, S. Determination of oxidation induction time and temperature bY DSC . J Therm Anal Calorim 83, 367–371 (2006). https://doi.org/10.1007/s10973-005-7142-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10973-005-7142-5