Skip to main content
Log in

Assay of an alpha solid waste drum using passive neutron counting

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A passive neutron based assaying system for plutonium bearing solid wastes has been designed and developed. The assaying of the plutonium in the drum containing the wastes is determined by as positioned and by rotating the drum to 180 degree and average counts are obtained. The average counts were used for deriving the counting statistics. This system was calibrated with plutonium typically obtained in fast reactor fuel reprocessing facilities with known isotopic compositions. The minimum detection limit has been estimated to be 35 mg. It has been determined that a γ background of up to 2000 mR/h can be tolerated without loss of accuracy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Venkataraman R, Marcel V, Stephen C, Patricia McClay, McElroy R, SusanKane WM, Robert E (2007) An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste. Nucl Inst Methods Phys Res A 579:375–379

    Article  CAS  Google Scholar 

  2. Ramaswami A, Singh S (2003) Gamma based Non destructive assay technique. Indian Association of Nuclear Chemists and Allied Scientists Bulletin

  3. Doug R, Norbert E, Hastings S, Jr (1991) The origin of neutron radiation. Passive Non destructive Assay of Nuclear Materials, U S Nuclear Regulatory Commission, Washington, Report LA-UR-90-732

  4. Menlove HO, Crane TW (1978) A 252Cf based non destructive assay system for fissile material. Nucl Inst Methods 152:549–557

    Article  CAS  Google Scholar 

  5. East LV, Parker JL, Reilly TD, Walton (1972) Gamma ray scanning system for barrels containing plutonium waste. LA-DC-12683, Nuclear energy symposium, San Francisco

Download references

Acknowledgements

The contributions of Shri.Amudharameshkumar, Shri.A.Palanivel, Shri C.R.Venkatasubramani, Chemical group, IGCAR, Dr.R.V.Subba rao, Head,PRCD,RPG Dr.R.Natarajan, Dr.A.Ravishankar, Former Directors, Reprocessing Group in design and commissioning are greatly acknowledged.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. Govindan.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sivakumar, P., Govindan, P. & Ananthasivan, K. Assay of an alpha solid waste drum using passive neutron counting. J Radioanal Nucl Chem 331, 3857–3864 (2022). https://doi.org/10.1007/s10967-022-08400-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-022-08400-3

Keywords

Navigation