Abstract
Based on the requirements of the lower detection limit for the low-volume gaseous effluent, we have designed an automatic separation apparatus of krypton (Kr). The principle of the apparatus is based on both the adsorption and desorption mechanism in the traps with the activated carbon particles and gas chromatography with 5A molecular sieves. The separation efficiency and overall recovery rate could be maintained at about (90.4 ± 4.2)% and (24.3 ± 1.3)%. The 85Kr could be radioassayed on a liquid scintillation counter following the automatic separation and loading into the cryogenic count vial. The detection limit based the low-volume of 3 L is about 9.5 Bq m−3, and the expanded relative uncertainties are in the range of 13–18% for typical measurements.
Similar content being viewed by others
References
Stricht SVD, and Janssens A (2010) Radiation protection 164 radioactive effluents from nuclear power stations and nuclear fuel reprocessing sites in the European Union, 2004-08
Zhang Q, Guo R, Zhang C, Chen X, Wang B (2014) Radioactive airborne effluents and the environmental impact assessment of CAP1400 nuclear power plant under normal operation. Nucl Eng Des 280:579–585
Kong TY, Kim S, Lee Y, Son JK, Maeng SJ (2017) Radioactive effluents released from Korean nuclear power plants and the resulting radiation doses to members of the public. Nucl Eng Technol 49:1772–1777
Sievers H (1991) Nuclear data sheets update for A = 85. Nucl Data Sheets 62:271–325
Ahlswede J, Hebel S, Ross JO, Schoetter R, Kalinowski MB (2013) Update and improvement of the global krypton-85 emission inventory. J Environ Radioact 115:34–42
Ministry of Environmental Protection(China) (2011) GB 6249-2011 regulations for environmental radiation protection of nuclear power plant
Huang Y-J, Guo G-Y, Zhang B, Tao Y-L, Sha X-D, Chen C-F, Shang-Guan Z-H (2017) Analysis and dose assessment of 85Kr released from NPP. Radiat Prot 37:73–79 (in Chinese)
Li H, Wang B (2014) Study on nobel gas 133Xe and 85Kr in gaseous effluent at TQNPP and its monitoring. Radiat Prot 34:194–213 (in Chinese)
Li F, Liu H, Liu H, Zhang Y, Cheng L, Sun W (2015) Proportoinal relationship analysis of 85Kr and 133Xe in the gaseous effluent on normal operating conditions of nuclear power plant. Radiat Prot Bull 35:28–32 (in Chinese)
Fang L, Liu X-H, Zhu Z-W, Jiang J (2016) Activity estimation of nobel gases released rom nuclear power platns. Nucl Sci Eng 36:306–312
European Commission (2018) European commission radioactive discharges database
USEPA, USDOD, USDOE, USDHS, USNRC, USDFA, USGS, and NIST (2004). Multi-agency radiological laboratory analytical protocols manual (MARLAP), NUREG-1576, EPA 402-B-04-001, NTIS PB2004-105421. Alexandria, VA, USA
Momoshima N, Inoue F, Sugihara S, Shimada J, Taniguchi M (2010) An improved method for 85Kr analysis by liquid scintillation counting and its application to atmospheric 85Kr determination. J Environ Radioact 101:615–621
Jao Y, Cheng WL, Chen HJ, Shaeh CC, Huang CC, Lin YM (1995) Determination of low level 85Kr and 133Xe concentrations in the environment. J Radioanal Nucl Chem 194:411–417
Janssens A, Buysse J, Cottens E (1985) The measurement of low-level atmospheric krypton-85. Nucl Instrum Methods Phys Res Sect A 234:335–343
Hebel S, Purtscher R, Goring F, Handsa J, Kirchner G (2015) Automated sampling and extraction of krypton from small air samples for Kr-85 measurement using atom trap trace analysis. In: Symposium on international safeguards: linking strategy, implementation and people (IAEA CN-220). International Atomic Energy Agency (IAEA), Vienna Austria
Tu L-Y, Yang G-M, Cheng C-F, Liu G-L, Zhang X-Y, Hu S-M (2014) Analysis of Krypton-85 and Krypton-81 in a few liters of air. Anal Chem 86:4002–4007
Yang G-M, Cheng C-F, Jiang W, Lu Z-T, Purtschert R, Sun Y-R, Tu L-Y, Hu S-M (2013) Analysis of 85Kr: a comparison at the 10–14 level using micro-liter samples. Sci Rep 3:1596
US Nuclear Regulatory Commission (1998) NUREG-1507, Minimum detectable concentrations with typical radiation survey instruments for various contaminants and field conditions. Washington, DC
Currie LA (1968) Limits for qualitative detection and quantitative determination. Application to radiochemistry. Anal Chem 40:586–593
Okai T, Takashima Y, Shiraishi N, Matsuoka N (1984) Measurement of krypton-85 in the atmosphere with a portable apparatus. J Radioanal Nucl Chem 81:161–165
Haynes WM (2014) CRC handbook of chemistry and physics. CRC Press, Boca Raton
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Huang, YJ., Guo, GY., Chen, CF. et al. Automated separation and analysis of krypton-85 from low-volume gaseous effluent of nuclear power plant. J Radioanal Nucl Chem 323, 213–222 (2020). https://doi.org/10.1007/s10967-019-06838-6
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-019-06838-6