Improved procedure for Pu/Am, and U isotope analysis in fecal samples

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Herein, we describe an improved procedure for 238Pu, 240Pu, 241Am, and natural U quantitation in fecal samples and validate it by analyzing reference samples of the intercomparison program. Interference caused by 237Np resulted in Pu content underestimation, which was corrected by the addition of an alternative tracer. Samples processed using the fusion method (to facilitate dissolution) exhibited significantly biased U contents compared to reference values, with the magnitude of the bias being dependent on the type of flux used. Conversely, the wet-ashing method afforded results closely matching reference values, being not significantly more time consuming than the fusion method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. International Atomic Energy Agency (2005) Generic procedures for medical response during a nuclear or radiological emergency. Austria, Vienna

    Google Scholar 

  2. Yoon S, Ha W-H, Yoo J, Lee S-S (2014) Screening of alpha-and beta-emitting radionuclides using liquid scintillation counting and monitoring procedures in radiation emergencies. Health Phys 107:382–387

    Article  CAS  PubMed  Google Scholar 

  3. International Atomic Energy Agency (2000) Indirect methods for assessing intakes of radionuclides causing occupational exposure. Austria, Vienna

    Google Scholar 

  4. Castellani C, Marsh J, Hurtgen C, Blanchardon E, Berard P, Giussani A (2013) IDEAS guidelines (version 2) for the estimation of committed doses from incorporation monitoring data. EURADOS report

  5. Maxwell SL, Culligan BK, Hutchison JB, Spencer RB (2013) Rapid fusion method for determination of actinides in fecal samples. J Radioannal Nucl Chem 298:1533–1542

    Article  CAS  Google Scholar 

  6. Sill D, Bohrer S (2000) Sequential determination of U, Pu, Am, Th and Np in fecal and urine samples with total sample dissolution. Radioact Radiochem 11:7–18

    CAS  Google Scholar 

  7. Eichrom Technologies Inc (2006) Analytical procedures-americium, neptunium, plutonium, thorium, curium, uranium, and strontium in water (with vacuum box system). Eichrom Technologies Inc, Lisle

    Google Scholar 

  8. ANSI (2011) Performance criteria for radiobioassay, Standard N13.30. American National Standards Institute

  9. Nour S, LaRosa J, Inn KGW (2011) Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program. Health Phys 101:170–175

    Article  CAS  PubMed  Google Scholar 

  10. Berard P, Fottorino R, Millot X (2011) PROCORAD’s proficiency tests as a means of analyzing capacities in emergency situations. Health Phys 101:136–139

    Article  CAS  PubMed  Google Scholar 

  11. Jukka L, Xiaolin H (2010) Chemistry and analysis of radionuclides. Wiley, Berlin

    Google Scholar 

  12. United States Environmental Protection Agency (2004) Multi-agency radiological laboratory analytical protocols manual. Washington, DC

  13. Maxwell SL, Culligan BK, Kelsey-Wall A, Shaw PJ (2011) Rapid radiochemical method for determination of actinides in emergency concrete and brick samples. Anal Chim Acta 701:112–118

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

This study was supported by a grant of the Korea Institute of Radiological and Medical Sciences (KIRAMS), funded by Ministry of Science and ICT (MSIT), Republic of Korea (No. 50535-2018).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jung-min Kim.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yoon, S., Ha, WH., Park, S. et al. Improved procedure for Pu/Am, and U isotope analysis in fecal samples. J Radioanal Nucl Chem 316, 1151–1155 (2018). https://doi.org/10.1007/s10967-018-5892-3

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-018-5892-3

Keywords

Navigation