Abstract
Research on transients is one of the main focuses in the field of accelerator driven subcritical reactor (ADSR). But inducing the transients by accelerator is inconvenient and costly. Simulating transients by sealed-tube neutron generator, through improving the driver of Penning ion source and modulating trigger signals of pulsed neutron, is a fast, accurate, reliable and low-cost method. This method has been used in simulating transients on the physics test platform of ADSR in China Institute of Atomic Energy (CIAE). And this method also can be applied in PGNAA.
Similar content being viewed by others
References
Papastefanou C (2004) Measurement of neutron flux and albedo of water for thermal neutrons with foils of indium in a subcritical nuclear reactor. J Radioanal Nucl Chem Lett 261(3):671–678
Miley GH, Ulmen B, Amadio G, Leon H, Shrestha PJ, Hora H (2009) Cylindrical IEC neutron source design for driven research reactor operation. J Radioanal Nucl Chem Lett 282(1):193–197
Bandini G, D’Angelo A, Gabrielli F, Meloni P, Monti S, Polidori M (2006) Transient analyses to support the definition of trade experiment start-up procedures. Nucl Instrum Methods Phys Res A 562(2):906–909
D’Angelo A (2003) Benchmark on beam interruptions in an accelerator-driven system. Nuclear Science NEA/NSC/DOC 17
Ahmad A, Lindley BA, Parks GT (2012) Accelerator-induced transients in accelerator driven subcritical reactors. Nucl Instrum Methods Phys Res Sect A 696:55–65
Zhang Y, Fokau A, Ishida S, Wallenius J (2011) Physics and safety studies of a compact ADS design loaded with nitride fuel. Ann Nucl Energy 38(11):2350–2355
Wang Z, Wang G, Gu Z, Jin M, Wu Y (2015) Benchmark of neutronics and thermal-hydraulics coupled simulation program NTC on beam interruptions in XADS. Ann Nucl Energy 77:172–175
Miley GH, Ulmen B, Amadio G, Leon H, Shrestha PJ, Hora H (2009) Cylindrical IEC neutron source design for driven research reactor operation. J Radioanal Nucl Chem Lett 282(1):193–197
Li G, Zhang Z-S, Chi Q, Liu L-M (2012) 50mm diameter digital DC/pulse neutron generator for subcritical reactor test. Nucl Instrum Methods Phys Res B 290:64–68
Tan H, Mitra S, Wielopolski L, Fallu-Labruyere A, Hennig W, Chu YX, Warburton WK (2008) A multiple time-gated system for pulsed digital gamma-ray spectroscopy. J Radioanal Nucl Chem Lett 276(3):639–643
Knauer W (1962) Mechanism of the penning discharge at low pressures. J Appl Phys 33(6):2093–2099
Rohwer P, Baumann H, Schütze W, Bethge K (1983) Studies of the center potential in a penning discharge. Nucl Instrum Methods Phys Res 211(2–3):543–546
Acknowledgments
The authors acknowledge funding by the Key Laboratory of Neutron Physics of China Academy of Engineering Physics (Grant No. 2013BC01) and the Fundamental Research Funds for the Central Universities.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Li, G., Shi, Y., Luo, H. et al. Simulating transients in the subcritical reactor by using a sealed-tube neutron generator. J Radioanal Nucl Chem 307, 2173–2179 (2016). https://doi.org/10.1007/s10967-015-4546-y
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-015-4546-y