Skip to main content
Log in

Startup of a new gas-filled recoil separator GARIS-II

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A new gas-filled recoil ion separator GARIS-II was on-line tested by using two 40Ar-induced fusion reactions of 169Tm(40Ar,4n)205Fr and 208Pb(40Ar,3n)245Fm, respectively. The products were collected to a focal plane with high efficiency of 47 ± 1 and 63 ± 9 % for 205Fr and 245Fm under low background condition.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Kaji D, Morimoto K, Sato N, Yoneda A, Morita K (2013) Nucl Instrum Methods B 317:311–314

    Article  CAS  Google Scholar 

  2. Kaji D, Morimoto K, Haba H, Wakabayashi Y, Kudou Y, Huang M, Goto S, Murakami M, Goto N, Koyama T, Tamura N, Tsuto S, Sumita T, Tanaka K, Takeyama M, Yamaki S, Morita K (2014) JPS Conf Proc 1:013051

    Google Scholar 

  3. Kaji D, Morita K, Morimoto K, Haba H, Kudo H (2011) Proc Radiochim Acta 1:105–107

    Google Scholar 

  4. Vermeulen D, Clerc HG, Sahm CC, Schmidt KH, Keller JG, Münzenberg G, Reisdorf W (1984) Z Phys A 318:157–169

    Article  CAS  Google Scholar 

  5. Münzenberg G, Hofmann S, Faust W, Heßberger FP, Reisdorf W, Schmidt KH, Kitahara T, Armbruster P, Güttner K, Thuma B, Vermeulen D (1981) Z Phys A 302:7–14

    Article  Google Scholar 

Download references

Acknowledgments

The experiment was performed at the RI Beam Factory operated by the RIKEN Nishina Center and CNS, University of Tokyo. The authors are grateful to the accelerator staff members for their cooperation and assistance during the experiment. This research was partially supported by a Grant-in-Aid for specially promoted research, 19002005, 2007, from the Ministry of Education, Culture, Sports, Science and Technology, Japan.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. Kaji.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kaji, D., Morimoto, K., Haba, H. et al. Startup of a new gas-filled recoil separator GARIS-II. J Radioanal Nucl Chem 303, 1523–1525 (2015). https://doi.org/10.1007/s10967-014-3706-9

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-014-3706-9

Keywords

Navigation