The correct and incorrect way to calibrate a Compton suppression counting system for gamma-ray efficiency

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

Gamma-ray efficiency calculations for a germanium detector have been made for a Compton suppression system. Results have shown that for radionuclides that have gamma rays in coincidence the photopeaks can be severely depressed leading to erroneous results. While this can be overcome in routine neutron activation analysis using a comparator method, special consideration must be given to determine the suppression for coincident gamma rays when calculating the efficiency curve and for radionuclide activities. This is especially important for users of the k 0 method and for fission product identification using Compton suppression methods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Ahmed YA, Landsberger S, O’Kelly DJ, Braisted J, Gabdo H, Ewa IOB, Umar IM, Funtua II (2010) Appl Radiat Isot 68:1909–1914

    Article  CAS  Google Scholar 

  2. Landsberger S, Biegalski S, O’Kelly DJ, Basunia S (2005) J Radioanal Nucl Chem 263:817–821

    Article  CAS  Google Scholar 

  3. Landsberger S, Wu D (1995) J Radioanal Nucl Chem 193:49–59

    Article  CAS  Google Scholar 

  4. El Abd A, Mostafa M, El-Amir MA (2012) J Radioanal Nucl Chem 293:255–260

    Article  Google Scholar 

  5. Çelik N, Çevik U, Küçükömeroğlu B (2102) J Radioanal Nucl Chem 292:1229–1235

    Article  Google Scholar 

  6. Proceedings of the 4th International k0-Users Workshop (2006) Nucl Instrum Methods Phys Res A 564: 629-76

    Google Scholar 

  7. Kubešová M, Kučera J (2012) J Radioanal Nucl Chem 293:87–94

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Landsberger.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Landsberger, S., Biegalski, S. & Kapsimalis, R. The correct and incorrect way to calibrate a Compton suppression counting system for gamma-ray efficiency. J Radioanal Nucl Chem 296, 309–313 (2013). https://doi.org/10.1007/s10967-012-2123-1

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-012-2123-1

Keywords

Navigation