Abstract
In this paper we describe the application of laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) coupling to particle analysis, i.e., the determination of the isotopic composition of micrometric uranium particles. The performances of this analysis technique are compared with those of the two reference particle analysis techniques: secondary ion mass spectrometry (SIMS) and fission track-thermo-ionization mass spectrometry (FT-TIMS), based on the measurement of the isotopic ratios of 235U/238U in particles present in an inter-comparison particulate sample. The agreement of the results obtained using LA-ICP-MS with target values and with the results obtained using FT-TIMS and SIMS was good. Accuracy was equivalent to that of the other two techniques (±3 % deviation). However, relative experimental uncertainties present with LA-ICP-MS (7 %) were higher than those present with FT-TIMS (4.5 %) and SIMS (3 %). Furthermore, measurement yield of LA-ICP-MS coupling was close to that obtained with the same quadrupole ICP-MS for the measurement of a liquid sample (~10−4), but lower than that obtained with FT-TIMS and SIMS, respectively, by a factor of 10 and 20, although the particles analyzed using LA-ICP-MS were most likely smaller (diameter ~0.6 μm, containing 4–7 fg of 235U). Nevertheless, thanks to the brevity of the signals obtained, the detection capacity for low isotopic concentrations by LA-ICP-MS coupling is equivalent to that of FT-TIMS, although it remains well below that of SIMS (×15). However, with more sensitive double focusing ICP-MS, performances equivalent to those achieved using SIMS could be obtained.
Similar content being viewed by others
References
Stetzer O, Betti M, Van Geel J, Erdmann N, Kratz JV, Schenkel R, Trautmann N (2004) Nucl Instrum Methods Phys Res, Sect A 525:582–592
Lee CG, Iguchi K, Inagawa J, Suzuki D, Esaka F, Magara M, Sakurai S, Watanabe K, Usuda S (2004) J Radioanal Nucl Chem 272:299–302
Shen Y, Zhao Y, Guo SL, Cui J, Liu Y, Li J, Xu J, Zhang H (2008) Radiat Meas 43:S299–S302
Tamborini G, Betti M, Forcina V, Hiernaut T, Giovanonne B, Koch L (1998) Spectrochim Acta B 53:1289–1302
Tamborini G, Betti M (2001) Mikrochim Acta 132:411–417
Ranebo Y, Hedberg PML, Whitehouse MJ, Ingeneri K, Littman S (2009) J Anal Atom Spectrom 24:277–287
Esaka F, Esaka KT, Lee CG, Magara M, Sakurai S, Usuda S, Watanabe K (2007) Talanta 71:1011–1015
Esaka F, Magara M, Lee CG, Sakurai S, Usuda S, Shinohara N (2009) Talanta 78:290–294
Esaka F, Watanabe K, Kukuyama H, Onodera T, Esaka KT, Magara M, Sakurai S, Usuda S (2004) J Nucl Sci Technol 41:1027–1032
Aregbe Y, Prohaska T, Stefanka Z, Széles E, Hubert A, Boulyga S (2011) ESARDA Bull 46:136–145
Boulyga SF, Prohaska T (2008) Anal Bioanal Chem 390:531–539
Varga Z (2008) Anal Chim Acta 625:1–7
Pointurier F, Pottin AC, Hubert H (2011) Anal Chem 83:7841–7848
Pointurier F, Hubert A, Baglan N, Hémet P (2008) J Radioanal Nucl Chem 276:505–511
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pointurier, F., Hubert, A. & Pottin, AC. Performance of laser ablation: quadrupole-based ICP-MS coupling for the analysis of single micrometric uranium particles. J Radioanal Nucl Chem 296, 609–616 (2013). https://doi.org/10.1007/s10967-012-2119-x
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-012-2119-x