Abstract
In the framework of a collaboration between laboratories involved in bulk U and Pu analysis of environmental samples (DIF centre of the French Commissariat à l’Energie Atomique, US National Laboratories of New Brunswick, Lawrence Livermore, Pacific Northwest, Oak Ridge, and Los Alamos), two round-robins were organised, each one consisting of the complete analysis (chemical preparation and isotope measurement) of three Quality Control samples. The samples were 10 × 10 cm cotton tissues (“swipe samples”) containing low amounts of U (from ~20 to ~150 ng) and Pu (from ~0.15 to ~10 pg). Despite using different spikes, different methods of sample preparation and different analytical instrumentation, the results for U and Pu contents and isotopic compositions reported by all laboratories are globally in good agreement. All laboratories are able to measure sub-pg amounts of U and Pu isotopes with acceptable accuracy and reproducibility, even if limited discrepancies are observed affecting one or other measurement and/or laboratory. General and laboratory specific recommendations were discussed and adopted to continue to improve the accuracy and precision of the measurements.
Similar content being viewed by others
References
Granier G, Pointurier F, Chartier F (2009) J Radioanal Nucl Chem 87:875–884
REIMPEP, NUSIMEP and IMEP inter-laboratory comparisons, (2012), organized by the IRMM (Geel, Belgium) http://irmm.jrc.ec.europa.eu/interlaboratory_comparisons. Accessed 23 July 2012
Mason P (2011) New Brunswick Laboratory (NBL) Safeguards Measurement Evaluation Program (SME). Annual Report—CY 2010 Results www.nbl.doe.gov/docs. Accessed 23 July 2012
Tandon L, Kuhn K, Decker D, Porterfiedl D, Laintz K, Wong A, Holland M, Peterson DS (2009) J Radioanal Nucl Chem 282:565–571
McCurdy D, Lin Z, Inn KGW, Bell R III, Wagner S, Erfurd DW, Steiner R, Duffy C, Hamilton TF, Brown TA, Marchetti AA (2005) J Radioanal Nucl Chem 263:447–455
Bores NE, Shultz MK, Rankin JM, Denton AJ, Payne GF (2008) J Radioanal Nucl Chem 277:111–116
Farmer OT III, Olsen KB, Thomas MS, Garofoli SJ (2008) J Radioanal Nucl Chem 276:489–492
Pointurier F, Hemet P, Hubert A (2008) J Anal At Spectrom 23:94–102
Pointurier F, Hubert A, Baglan N, Hemet P (2008) J Radioanal Nucl Chem 276:505–511
Pointurier F, Hubert A, Fauré AL, Hemet P, Pottin AC (2011) J Anal At Spectrom 26:1474–1480
Neuilly M (1999) Modelling and estimation of measurement errors. Intercept Ltd, Hampshire
Williams RW (2010), LLNL-CONF-455394 (15 September, 2010) Safeguards Symposium, Vienna, Austria, 1–5 November, 2010
Acknowledgments
Many thanks to all the people who make this collaboration possible and to the people who actively participate in the collaboration, through meetings, administrative matters, and, of course through technical work in the facilities. Special thanks to Ross Williams and his colleagues from LLNL, who assumed the difficult task to prepare and dispatch the QC samples.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Pointurier, F., Williams, R.W., LaMont, S.P. et al. Round-robins in the area of uranium and plutonium bulk analysis of environmental samples. J Radioanal Nucl Chem 296, 599–608 (2013). https://doi.org/10.1007/s10967-012-1985-6
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-012-1985-6