Abstract
This paper presents the alpha/beta complete deconvolution tool (ABCD-Tool), a C++ application for the analysis of spectra from liquid scintillation counting (LSC) measurements. In addition to the basic algorithms for standard gross alpha/beta analysis and the determination of the counting efficiency, the software implements a recent unfolding technique based on Fourier transforms, which gives precise and reliable results even in the case of complex, strongly overlapping spectra. The application is designed to be used with alpha/beta spectra generated from Perkin Elmer Wallac Quantulus 1220. However, future upgrades are scheduled in order to extend the compatibility to spectra from other LSC instruments in commerce.
Similar content being viewed by others
References
Hou X (2007) Radiochemical analysis of radionuclides difficult to measure for waste characterization in decommissioning of nuclear facilities. J Radioanal Nucl Chem 273:43–48
Makinen P (1995) Handbook of liquid scintillation counting. Department of Telecommunications, Institute of Technology, Turku
Passo CJ, Cook GT (1994) Handbook of environmental liquid scintillation spectrometry. Packard BioScience Company, Meriden
Passo CJ, Eskola A (2007) Basic principles of LSC. Perkin Elmer Life and Analytical Sciences, Shelton
Grau CA (1994) A new linear spectrum unfolding method applied to radionuclide mixtures in liquid scintillation spectrometry. Appl Radiat Isot 45:83–90
Grau CA (1996) MLOG, the simultaneous standardization of multi-nuclide mixtures. Comput Phys Commun 95:48–52
Grau CA, Martin-Casallo MT, Grau MA (1991) Spectrum unfolding and double window methods applied to standardization of 14C and 3H mixtures. Nucl Instrum Methods Phys Res A307:484–490
Grau CA, Rodriguez BL, Grau MA (1993) Standardization of multi-nuclide mixtures by a new spectrum unfolding method. J Radioanal Nucl Chem 176:391–403
Grau CA, Rodriguez BL, Grau MA (1994) Deconvolution of 204Tl/36Cl and 147Pm/45Ca dual mixtures. Nucl Instrum Methods Phys Res A339:71–77
Takiue M, Matsui Y, Natake T, Yoshizawa Y (1990) A new approach to analytical radioassay of multiple beta-labeled samples using a liquid scintillation spectrometer. Nucl Instrum Methods Phys Res A293:596–600
Takiue M, Matsui Y, Fujii H (1991) Liquid scintillation radioassay for multiple radionuclide mixtures by the most probable value theory. J Radioanal Nucl Chem 152:227–236
Takiue M, Fujii H, Natake T, Matsui Y (1991) Analytical measurements of multiple beta-emitter mixtures with a liquid scintillation spectrometer. J Radioanal Nucl Chem 155:183–193
Takiue M, Natake T, Fujii H (1995) Liquid scintillation radioassay for low-activity beta-emitter mixtures by the method of least squares. J Radioanal Nucl Chem 200:247–258
Remetti R, Sessa A (2011) Beta spectra deconvolution for liquid scintillation counting. J Radioanal Nucl Chem 287:107–111
L’Annunziata MF, Kessler MJ (1998) Radiotracer Liquid Scintill Anal. In: L’Annunziata MF (ed) Handbook of radioactivity analysis. Academic, Amsterdam, pp 225–242
Oikari T, Kojola H, Nurmi J, Kaihola L (1987) Simultaneous counting of low alpha- and beta-particle activities with liquid-scintillation spectrometry and pulse-shape analysis. Appl Radiat Isot 38:875–878
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Remetti, R., Franci, D. ABCD-Tool, a software suite for the analysis of α/β spectra from liquid scintillation counting. J Radioanal Nucl Chem 292, 1115–1122 (2012). https://doi.org/10.1007/s10967-012-1664-7
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-012-1664-7