Advertisement

Journal of Radioanalytical and Nuclear Chemistry

, Volume 291, Issue 2, pp 281–285 | Cite as

An automated delayed neutron counting system for mass determinations of special nuclear materials

  • M. T. Sellers
  • D. G. Kelly
  • E. C. Corcoran
Article

Abstract

An automated delayed neutron counting (DNC) system has been developed at the Royal Military College of Canada (RMC) to enhance nuclear forensics capabilities pertaining to special nuclear material analysis. The system utilises the SLOWPOKE-2 Facility at RMC as a neutron source and 3He detectors. System control and data acquisition occur through a LabVIEW platform. The time dependent count rate of the delayed neutron production has been examined for 235U, using certified reference materials. Experimental validation according to ISO 17025 protocols suggests typical errors and precision of −3.6 and 3.1%, respectively, and a detection limit of 0.26 μg 235U.

Keywords

Delayed neutron counting Nuclear forensics Special nuclear materials 

Notes

Acknowledgments

Financial support has been provided by the Director General of Nuclear Safety, the Analytical Sciences Group and the SLOWPOKE-2 Facility at the Royal Military College of Canada. The authors would like to thank Dave Ferguson, John Shaw, Matthew Mackay, Kathy Nielsen and Kristine Mattson for their assistance.

References

  1. 1.
    Consolidated Canadian Results to the HEU Round Robin Exercise (2004) Defence R&D Canada, Ottawa. http://cradpdf.drdc.gc.ca/PDFS/unc62/p522801.pdf. Accessed 16 Feb 2011
  2. 2.
    Nuclear Forensic Field Exercise #1 (2006) Defence R&D Canada, Ottawa. http://www.ottawa.drdc-rddc.gc.ca/docs/e/TM-2006-214-eng.pdf. Accessed 16 Feb 2011
  3. 3.
    Keeping R (1958) Nucl Energy 7:13–34CrossRefGoogle Scholar
  4. 4.
    Handbook of Nuclear Data for Safeguards (2008) International Atomic Energy Agency, Vienna. http://www-nds.iaea.org/sgnucdata/safeg2008.pdf. Accessed 16 Feb 2011
  5. 5.
    Li X, Henkelmann R, Baumgärtner F (2004) Nucl Instrum Methods Phys Res B 215:246–251CrossRefGoogle Scholar
  6. 6.
    Papadopoulos NN, Tsagas NF (1994) J Radioanal Nucl Chem 179(1):35–43CrossRefGoogle Scholar
  7. 7.
    BSEN (2005) ISO/IEC 17025 general requirements for the competence of testing and calibration laboratories. International Standards Organization, GenevaGoogle Scholar
  8. 8.
    Andrews WS (1989) thermal neutron flux mapping around the reactor core of the SLOWPOKE-2 at RMC, MASC Thesis, Royal Military College of CanadaGoogle Scholar
  9. 9.
    Kelly DG, Bennett LGI, Fill MM, Mattson KM, Nielsen KS, White SD, Allen JF (2008) J Radioanal Nucl Chem 278(3):807–811CrossRefGoogle Scholar
  10. 10.
    Duke MJ (1983) Geochemistry of Exshaw Shale of Alberta—an application in neutron activation analysis and related techniques, MASC Thesis, University of AlbertaGoogle Scholar
  11. 11.
    Knoll GF (2000) Radiation detection and measurement, 3rd edn. John Wiley & Sons, New YorkGoogle Scholar

Copyright information

© Akadémiai Kiadó, Budapest, Hungary 2011

Authors and Affiliations

  1. 1.Department of Chemistry and Chemical Engineering, SLOWPOKE-2 Facility and Analytical Science GroupRoyal Military College of CanadaKingstonCanada

Personalised recommendations