Abstract
The replicate sample instrumental neutron activation method was optimized and used for the determination of selenium in foodstuffs. The method was reliable, yielding accurate results. Lower detections limits were obtained after each successive irradiation. Different irradiation conditions were used depending on the type of sample. For samples with higher selenium contents (meat, fish, eggs), the measured selenium in the first replicate is in all cases larger than the detection limit, but a better accuracy was obtained with a larger number of replicates (2–3 replicates). For samples with extremely low selenium contents (vegetable samples), at least seven replicates were necessary to obtain a concentration value two times larger than the detection limit.
Similar content being viewed by others
References
Borella, P., Bargellini, A., Caselgrandi, E., Menditto, A., Patriarca, M., Taylor, A., Vivoli, G.: Microchem. J. 58, 325 (1998)
Spyrou, N.M.: J. Radioanal. Chem. 61, 211 (1981)
Reis, M.F., Martinho, E.: J. Radioanal. Nucl. Chem. 167, 39 (1993)
Guinn, P.: Radiochem. Radioanal. Lett. 44, 133 (1980)
Parry, S.J.: J. Radioanal. Nucl. Chem. 112, 383 (1986)
Ventura, M.G., Freitas, M.C., Pacheco, A.M.G., Van Meerten, T., Wolterbeek, T.H.: Eur. Food Res. Technol. 224, 395 (2007)
Combs Jr., G.F.: Br. J. Nutr. 85, 517 (2001)
Yoshida, M., Abe, M., Fukunaga, K., Kikuchi, K.: Food Addit. Contam. 19, 990 (2002)
Instituto Nacional de Estatística (INE), Estatísticas Agrícolas. http://www.ine.pt/portal/page/portal/PORTAL_INE/Publicacoes?PUBLICACOESpub_boui=129237&PUBLICACOESmodo=2 (2005) (in Portuguese). Accessed 15 Nov 2007
Instituto Nacional de Estatística (INE), Estatísticas Agrícolas. http://www.ine.pt/portal/page/portal/PORTAL_INE/Publicacoes?PUBLICACOESpub_boui=6209833&PUBLICACOESmodo=2 (2006) (in Portuguese). Accessed 15 Nov 2007
Instituto Nacional de Estatística (INE), Balança Alimentar Portuguesa. http://www.ine.pt/portal/page/portal/PORTAL_INE/Publicacoes?PUBLICACOESpub_boui=375238&PUBLICACOESmodo=2 (1990–1997) (in Portuguese). Accessed 4 Oct 2006
Acknowledgements
A PhD grant (SFRH/BD/10288/2002) from Fundação para a Ciência e a Tecnologia (FCT, Portugal) has supported this work.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ventura, M.G., Freitas, M.C. & Pacheco, A.M.G. Determination of selenium in food matrices by replicate sample neutron activation analysis. J Radioanal Nucl Chem 281, 197–200 (2009). https://doi.org/10.1007/s10967-009-0117-4
Received:
Published:
Issue Date: