Skip to main content
Log in

Elemental analysis of hair using PIXE-tomography and INAA

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

3D quantitative elemental maps of a section of a strand of hair were produced using a combination of PIXE-Tomography and simultaneous On/Off Axis STIM-Tomography at the University of Surrey Ion Beam Centre. The distributions of S, K, Cl, Ca, Fe and Zn were determined using the PIXE-T reconstruction package DISRA. The results were compared with conventional bulk PIXE analysis of tomographic data as determined using Dan32. The overall concentrations determined by PIXE were compared with elemental concentrations held in the University of Surrey Hair Database. All the entries currently in the database were produced using INAA. The merits and possible contributions of tomographic PIXE analysis to analysis of hair are discussed. The conclusions drawn from the PIXE-Tomography analysis can be used to argue for more stringent procedures for hair analysis at the University of Surrey.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D. Beasley, N. M. Spyrou, J. Radioanal. Nucl. Chem., 264 (2005) 289.

    Article  Google Scholar 

  2. W. J. Altaf, O. A. Akanle, L. L. Admans, D. Beasley, C. Butler, N. M. Spyrou, J. Radioanal. Nucl. Chem., 259 (2004) 493.

    Article  CAS  Google Scholar 

  3. A. Sakellariou, D. N. Jamieson, G. J. F. Legge, Nucl. Instr. Meth., B181 (2001) 211.

    Google Scholar 

  4. G. W. Grime, Nucl. Instr. Meth., B109/110 (1996) 170.

    Google Scholar 

  5. J. Dombovari, L. Papp, I. Uzonyi, K. Borbely, Z. Elekes, Z. Varga, J. Matyus, G. Kakuk, J. Anal. At. Spectrom., 14 (1999) 553.

    Article  CAS  Google Scholar 

  6. P. M. Jenneson, A. S. Clough, J. L. Keddie, J. R. Lu, P. Meredith, Nucl. Instr. Meth., B132 (1997) 697.

    Google Scholar 

  7. G. Forte, A. Alimonti, N. Violante, M. Di Gregorio, O. Senofonte, F. Petrucci, G. Sancesario, B. Bocca, J. Trace Elem. Med. Biol., 19 (2005) 195.

    Article  CAS  Google Scholar 

  8. N. Miekeley, M. T. Dias Carneiro, C. L. Da Silveira, Sci. Total Environ., 218 (1998) 9.

    Article  CAS  Google Scholar 

  9. B. Stocklassa, J. Cosmetic Sci., 52 (2001) 297.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. Beasley.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Beasley, D., Gomez-Morilla, I. & Spyrou, N. Elemental analysis of hair using PIXE-tomography and INAA. J Radioanal Nucl Chem 276, 101–105 (2008). https://doi.org/10.1007/s10967-007-0416-6

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-007-0416-6

Keywords

Navigation