Monte Carlo generated spectra for QA/QC of automated NAA routine

  • Published:
Journal of Radioanalytical and Nuclear Chemistry Aims and scope Submit manuscript

Abstract

A quality check for an automated system of analyzing large sets of neutron activated samples has been developed. Activated samples are counted with an HPGe detector, in conjunction with an automated sample changer and spectral analysis tools, controlled by the Canberra GENIE 2K and REXX software. After each sample is acquired and analyzed, a Microsoft Visual Basic program imports the results into a template Microsoft Excel file where the final concentrations, uncertainties, and detection limits are determined. Standard reference materials are included in each set of 40 samples as a standard quality assurance/quality control (QA/QC) test. A select group of sample spectra are also visually reviewed to check the peak fitting routines. A reference spectrum was generated in MCNP 4c2 using an F8, pulse-height, tally with a detector model of the actual detector used in counting. The detector model matches the detector resolution, energy calibration, and counting geometry. The generated spectrum also contained a radioisotope matrix that was similar to what was expected in the samples. This spectrum can then be put through the automated system and analyzed along with the other samples. The automated results are then compared to expected results for QA/QC assurance.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. S. Landsberger, K. Jackman, L. Welch, Neutron activation analysis using excel files and Canberra GENIE-2000, J. Radioanal. Nucl. Chem., 264 (2005) 235.

    Article  CAS  Google Scholar 

  2. R. J. Gehrke, R. P. Keegan, P. J. Taylor, Specifications for today’s coaxial HPGe detectors, ANS Annual Meeting, Milwaukee, WI, 2001.

  3. R. L. Metzger, K. A. Van Riper, K. J. Kearfott, Radionuclide depth distribution by collimated spectroscopy, ANS Topical Meeting, Santa Fe, NM, 2002.

  4. G. Knoll, Radiation Detection and Measurement, 2nd ed., John Wiley & Sons, New York, 1989, pp. 50; 117; 370.

    Google Scholar 

  5. J. Rodenas, V. Serradell, J. Ortiz, L. Ballesteros, Influence of the Ge inactive layer thickness on detector calibration simulation for environmental radioactive samples using the Monte Carlo method, 3rd Annual Symp. on Sensitivity Analysis of Model Output, Madrid, Spain, June 18–20, 2001.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jackman, K.R., Biegalski, S.R. Monte Carlo generated spectra for QA/QC of automated NAA routine. J Radioanal Nucl Chem 271, 207–211 (2007). https://doi.org/10.1007/s10967-007-0131-3

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-007-0131-3

Keywords

Navigation