Skip to main content
Log in

Polarization Sensitive Subcutaneous and Muscular Imaging Based on Common Path Optical Coherence Tomography Using Near Infrared Source

  • Original Paper
  • Published:
Journal of Medical Systems Aims and scope Submit manuscript

Abstract

In this paper, we describe a polarization sensitive (PS) subcutaneous and muscular imaging system based on common path optical coherence tomography (CP-OCT) using a near infrared source. The axial and lateral resolutions of the PS-OCT system are 9 and 6 μm, respectively. The main goal of this work is to build a high-resolution and minimally invasive optical imager for examining various kinds of cutaneous substructures with intrinsic or form birefringence. The internal structural information is extracted by the real-time signal analysis (Fourier Transform) of the modulated spectral intensity depending on the beam and tissue birefringence. The preliminary results using fresh beef longissimus muscle and in vivo Rattus norvegicus (rat) show that it is possible to visualize the birefringence effect of the tissue collagen fibers in the samples in order to achieve superior image contrast and sensitivity for the detection of hidden dermal structures. Compared to conventional CP-OCT, the proposed PS-OCT system provides depth-resolved images, which reflect the tissue birefringence.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Singer, A. J., and Clark, R. A., Cutaneous wound healing. N. Engl. J. Med. 341:738–746, 1999.

    Article  Google Scholar 

  2. Wang, Z., Pan, H., Yuan, Z., Liu, J., Chen, W., and Pan, Y., Assessment of dermal wound repair after collagen implantation with optical coherence tomography. Tissue Eng. C. 14:35–45, 2008.

    Article  Google Scholar 

  3. Sakai, S., Yamanari, M., Miyazawa, A., Matsumoto, M., Nakagawa, N., Sugawara, T., Kawabata, K., Yatagai, T., and Yasuno, Y., In vivo three-dimensional birefringence analysis shows collagen differences between young and old photo-aged human skin. J. Invest. Dermatol. 128:1641–1647, 2008.

    Article  Google Scholar 

  4. Fujimoto, J. G., Optical coherence tomography for ultrahigh resolution in vivo imaging. Nature Biotechnol. 21:1361–1367, 2003.

    Article  Google Scholar 

  5. Gambichler, T., Moussa, G., Sand, M., Sand, D., Altmeyer, P., and Hoffmann, K., Applications of optical coherence tomography in dermatology. J. Dermatol. Sci. 40:85–94, 2005.

    Article  Google Scholar 

  6. Cobb, M. J., Chen, Y., Underwood, R. A., Usui, M. L., Olerud, J., and Li, X., Noninvasive assessment of cutaneous wound healing using ultrahigh-resolution optical coherence tomography. J. Biomed. Opt. 11:064002, 2006.

    Article  Google Scholar 

  7. Yamanari, M., Makita, S., Madjarova, V. D., Yatagai, T., and Yasuno, Y., Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method. Opt. Express. 14:6502–6515, 2006.

    Article  Google Scholar 

  8. Weissman, J., Hancewicz, T., and Kaplan, P., Optical coherence tomography of skin for measurement of epidermal thickness by shapelet-based image analysis. Opt. Express. 12:5760–5769, 2004.

    Article  Google Scholar 

  9. Gambichler, T., Matip, R., Moussa, G., Altmeyer, P., and Hoffmann, K., In vivo data of epidermal thickness evaluated by optical coherence tomography: Effects of age, gender, skin type, and anatomic site. J. Dermatol. Sci. 44:145–152, 2006.

    Article  Google Scholar 

  10. Vakhtin, A. B., Kane, D. J., Wood, W. R., and Peterson, K. A., ‘Common-path interferometer for frequency-domain optical coherence tomography. Appl. Opt. 42:6953–6958, 2003.

    Article  Google Scholar 

  11. Li, X., Han, J. -H., Liu, X., and Kang, J. U., Signal-to-noise ration analysis of all-fiber common-path optical coherence tomography. Appl. Opt. 47:4833–4840, 2008.

    Article  Google Scholar 

  12. Tan, K. M., Mazilu, M., Chow, T. H., Lee, W. M., Taguchi, K., Ng, B. K., Sibbett, W., Herrington, C. S., Brown, C. T. A., and Dholakia, K., In-fiber common-path optical coherence tomography using a conical-tip fiber. Opt. Express. 17:2375–2384, 2009.

    Article  Google Scholar 

  13. Liu, X., Li, X., Kim, D. -H., Ilev, I., and Kang, J. U., Fiber-optic fourier-domain common-path OCT. Chin. Opt. Lett. 6:899–901, 2008.

    Article  Google Scholar 

  14. Derickson, D., Fiber Optic Test and Measurement. Prentice Hall, Upper Saddle River, NJ, 1998.

    Google Scholar 

  15. Zhang, K., Han, J. -H., and Kang, J. U., All-fiber common-path fourier-domain optical coherence microscopy for 3D in vivo endoscopic subcellular imaging. Conference on Lasers and Electro-Optics (CLEO), JWA74, Baltimore, MD, 2009.

Download references

Acknowledgments

This work was supported by the second stage of the Brain Korea 21 Project in 2009 and a Korean Science and Engineering Foundation (KOSEF) grant funded by the Korea government (MEST) (NO. R01-2008-000-20089-0), and partially supported 2006 CBNU funds.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Chul Gyu Song.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Han, JH., Kang, J.U. & Song, C.G. Polarization Sensitive Subcutaneous and Muscular Imaging Based on Common Path Optical Coherence Tomography Using Near Infrared Source. J Med Syst 35, 521–526 (2011). https://doi.org/10.1007/s10916-009-9388-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10916-009-9388-0

Keywords

Navigation