Skip to main content
Log in

Calorimetric Low-Temperature Detectors for X-Ray Spectroscopy on Trapped Highly-Charged Heavy Ions

  • Published:
Journal of Low Temperature Physics Aims and scope Submit manuscript

Abstract

The application of Calorimetric Low-Temperature Detectors (CLTDs) has been proposed at the Heavy-Ion TRAP facility HITRAP which is currently being installed at the Helmholtz Research Center for Heavy Ion Research GSI. This cold ion trap setup will allow the investigation of X-rays from ions practically at rest, for which the excellent energy resolution of CLTDs can be used to its full advantage. However, the relatively low intensities at HITRAP demand larger solid angles and an optimized cryogenic setup. The influence of external magnetic fields has to be taken into account. CLTDs will also be a substantial part of the instrumental equipment at the future Facility for Antiproton and Heavy Ion Research (FAIR), for which a wide variety of high-precision X-ray spectroscopy experiments has been proposed. This contribution will give an overview on the chances and challenges for the application of CLTDs at HITRAP as well as perspectives for future experiments at the FAIR facility.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. V. Andrianov et al., AIP Conf. Proc. 1185, 99 (2009)

    Article  ADS  Google Scholar 

  2. www.gsi.de

  3. H.-J. Kluge et al., Inst. Phys. Conf. Ser. 58, 9 (2007)

    Article  ADS  Google Scholar 

  4. W. Quint et al., Hyperfine Interact. 132, 457 (2001)

    Article  ADS  Google Scholar 

  5. H. Reich et al., Nucl. Phys. A 626, 417c (1997)

    Article  ADS  Google Scholar 

  6. K. Stiebing, private communications, 2010

  7. P. Egelhof, S. Kraft-Bermuth, Top. Appl. Phys. 99, 469 (2005)

    Google Scholar 

  8. S.G. Podorov et al., J. Phys. D 34, 2363 (2001)

    Article  ADS  Google Scholar 

  9. P. Beiersdorfer et al., Phys. Rev. Lett. 71, 3939 (1993)

    Article  ADS  Google Scholar 

  10. C. Branau et al., Hyperfine Interact. 146, 41 (2003)

    Article  ADS  Google Scholar 

  11. P. Egelhof, S. Kraft-Bermuth, AIP Conf. Proc. 1185, 761 (2009)

    Article  ADS  Google Scholar 

  12. FAIR Baseline Technical Report, July 2006, http://www.gsi.de/fair/reports/btr.html

Download references

Acknowledgements

We thank H.-J. Kluge and T. Stöhlker from the SPRAC collaboration for their great support and many fruitful discussions. This work is supported by the Emmy Noether Young Researchers Program of the Deutsche Forschungsgemeinschaft (DFG).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Kraft-Bermuth.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kraft-Bermuth, S., Andrianov, V., Bleile, A. et al. Calorimetric Low-Temperature Detectors for X-Ray Spectroscopy on Trapped Highly-Charged Heavy Ions. J Low Temp Phys 167, 765–770 (2012). https://doi.org/10.1007/s10909-012-0520-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10909-012-0520-z

Keywords

Navigation