Abstract
At present, it is necessary to check the quality of many food products in which the content of coumarins is limited. Since a rapid and simple method for the determination of coumarin (COU), 4-hydroxycoumarin (4HC) and dicoumarol (DC) in tea samples was needed, we developed an alternative option to chromatography, i.e., fluorescence spectroscopy with multivariate calibration. The synchronous fluorescence spectra were recorded at constant wavelength differences 70, 80 and 90 nm from 200 to 400 nm. The different experimental parameters affecting the synchronous fluorescence intensities of the analytes were carefully studied and optimized. Partial least squares (PLS) method and multi linear regression (MLR) were compared on determining the concentrations. The best results were obtained by the PLS method on synchronous fluorescence spectra at Δλ = 90 nm. The results from the analysis of herbal tea Melilotus officinalis by synchronous fluorescence spectroscopy with PLS model are equivalent with the results from HPLC. Fisher F- test and Student’s t- test confirmed this finding.
Similar content being viewed by others
References
Kim E, Park SB (2010) In: Demchenko AP (ed) Advanced fluorescence reposters in chemistry and biology I: fundamentals and molecular design. Springer, Berlin, pp 149–186
Raters M, Matissek R (2008) Eur Food Res Technol 227:637–642
EFSA, in Opinion of the scientific panel on food additives, flavourings, processing aids and materials in contact with food (AFC) on request from the commission related to coumarin, adopted on 6 October 2004 EFSA J. 104:1–36
Oldenburg J, Rost S, Seidel H, Watzka M, Mueller-Reible CR (2008) Med Gen 20:230–235
Hamerschlak N, Rosenfeld LGM (1996) Arq Bras Cardiol 67:209–213
Edwards WC, Burrows GE, Tyr RJ (1984) Okla Vet Med Assoc 36:30–32
Campbell HA, Link KP (1941) J Biol Chem 138:21–33
Commission Regulation (EU) No 344/2013 of the European Parliament and of the Council of 4 April 2013 on cosmetic products. Official J of the Euro Union L 114:53
Regulation (EC) No 1334/2008 of the European Parliament and of the Council of 16 December 2008 on flavourings and certain food ingredients with flavouring properties for use in and on foods and amending Council Regulation (EEC) No 1601/91, Regulations (EC) No 2232/96 and (EC) No 110/2008 and Directive 2000/13/EC. Official J of the Euro Union L 354/34:15
Nie JF, Wu HL, Zhu SH, Han QJ, Fu HY (2008) Talanta 75:1260–1268
Xi HW, Ma Q, Wang C, Bai H, Liu X, Wang Y (2010) J Instrum Anal 12:1168–1172
Li J, Li N, Wu T, Wang C (2005) Life Sci Instrum 5:34–38
Zhao XY, Fu XF, Wang P, Li J, Hu XZ (2011) J Anal Sci 1:49–52
Zhao XY, Lin YF, Hu XZ, Wang P, Fu XF, Ji L (2010) Chin J Anal Lab 3:76–79
Wu Y, Han X, Zhang J-H, Yan F-L (1998) Grassl China 1:36–38
Patra D, Mishra AK (2002) Trends Anal Chem 21:787–798
Pistonesi MF, Di Nezio MS, Centurion ME, Palomeque ME, Lista AG, Fernandez BS (2006) Talanta 69:1265–1268
de la Peiia M, Moreno MD, Durhn-Me I, Salinas F (2006) Talanta 43:1349–1356
Luis ML, Fraga JMG, Jiménez AI, Jiménez F, Hernández O, Arias JJ (2004) Talanta 62:307–316
Divya O, Mishra AK (2007) Talanta 72:43–48
Žiak Ľ, Májek P, Hroboňová K, Čacho F, Sádecká J (2014) Food Chem 159:282–286
Galera MM, Zamora DP, Vidal JM, Frenich AG, Espinosa-Mansilla A, de la Pena AM, Lopez FS (2003) Talanta 59:1107–1116
Tamhane C (2012) In: Balding DJ et al (eds) Statistical analysis of designed experiments: theory and applications. Wiley- Interscience, New Jersey, pp 300–351
Brereton RG (2000) Analyst 125:2125–2154
Wise BM, Gallagher NB, Bro R, Shaver JM, Windig W, Koch RS (2006) PLS toolboox 4.0 for use with MatlabTM. Eigenvector Research Inc, Wenatchee, pp 137–167
Wold S, Sjostrom M, Eriksson L (2008) Chemometr Intell Lab Syst 58:109–130
Brown SH (2009) Ala J Math 34:1–3
Acknowledgments
This publication was supported by the Competence Center for SMART Technologies for Electronics and Informatics Systems and Services, ITMS 26240220072, funded by the Research&Development Operational Programme from the ERDF and the Slovak Research and Development Agency under the contract No. APVV-0797-11.
Conflict of Interest
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Poláček, R., Májek, P., Hroboňová, K. et al. Fluorescence Spectroscopy as a Tool for Determination of Coumarins by Multivariate Calibration. J Fluoresc 25, 297–303 (2015). https://doi.org/10.1007/s10895-015-1508-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10895-015-1508-2