The paper presents the determination of the pesticide 3-indolyl acetic acid based on its native fluorescence; the method has been optimised either in a flow injection analysis (FIA) assembly or in batch. Maximum fluorescence intensity was observed at basic pH solutions at λexc = 280 nm and λem = 364 nm. The influence of different empirical parameters as pH, surfactants presence, solvent polarity, solved oxygen amount, and temperature was studied; highest outputs only required the pH in aqueous solutions to be adjusted over the range 9.5–10.5. Different calibration ranges were obtained by working with three different sensitivity scales of the fluorimeter either in flow injection analysis or batch. With the high sensitivity scale and FIA, the linear dynamic range was from 0.005 to 0.6 mg L−1 3-indolyl acetic acid; with an relative standard deviation (RSD) of 4.9% inter-day reproducibility. A large series of potential interferents was studied and finally, the method was applied to several water samples.
Similar content being viewed by others
References
P. Hu, D. H. Hu, and H. Yang (2001). Determination of plant growth hormones in earthworm casts by high-performance liquid chromatography. Fenxi-Shiyanshi 20(6), 8–10.
Z. Zhang, Q. Zhang, Z. Wang, R. F. Lin, and Y. R. Tao (1994). High-performance liquid chromatography (HPLC) determination of internal hormones in buckwheat seedlings. Sepu 12(2), 140–141.
J. Hansen-Moeller (1992). Determination of indolic compounds in pig back fat by solid-phase extraction and gradient high-performance liquid chromatography with special emphasis on the boar taint compound skatole. J. Chromatogr. 624(1–2), 479–490.
Y. G. Du, S. G. Li, and H. L. Guo (2003). Differential display of plant internal secretion by high-performance liquid chromatography-coulometric array detection. Sepu 21(5), 507–509.
J. P. Danaceu, G. M. Andersen, W. M. McMahon, and D. J. Crounch (2003). J. Anal. Toxicol. 27(7), 440–444.
R. Z. Wang, L. T. Xiao, W. H. Lin, Y. Cao, and X. Y. Bo (2002). High-performance liquid chromatography determination of internal hormones in inter-subspecific hybrid rice. Sepu 20(2), 148–150.
Z. X. Lu and W. Song (2000). Development of a chemiluminescent method for the simultaneous determination of pyruvic and tartaric acids in human serum based upon their reaction with cerium (IV) in the presence of rutheniumtrispyridine. Sepu 18(4), 328–331.
J. Olsson, K. Claeson, B. Karlberg, and A. C. Nordström (1998). Determination of indole-3-acetic acid and indole-3-acetyl in pea plant with capillary electrophoresis and fluorescence detection. J. Chromatogr. A 824(1), 231–239.
A. Segura-Carretero, C. Cruces-Blanco, M. Soriano-Peña, S. Cortacero-Ramirez, and A. Fernández-Gutierrez (2004). Determination of phytohormones of environmental impact by capillary zone electrophoresis. J. Agric. Food Chem. 52(6), 1419–1422.
G. Sandberg, K. Ljung, and P. Alma (1985). Precision and accuracy of radio-immunoassay in the analysis of endogenous indol-3-ylacetic from needles of Scots pine. Phytochemistry 24(7), 1431–1442.
K. B. Wu, Y. Y. Sun, and S. S. Hu (2003). Nanogold on powdered cobalt oxide for carbon monoxide sensor. Sens. Actuators B 96(3), 658–662.
S. L. Morgan and S. N. Deming (1974). Simplex optimisation of analytical chemical methods. Anal. Chem. 46, 1170–1175.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Calatayud, J.M., de Ascenção, J.G. & Albert-García, J.R. FIA-Fluorimetric Determination of the Pesticide 3-Indolyl Acetic Acid. J Fluoresc 16, 61–67 (2006). https://doi.org/10.1007/s10895-005-0041-0
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10895-005-0041-0