Abstract
The two-electrode gas switch has been widely used in ShengGuang-III power conditioning system, while due to triggered by a negative high-voltage nanosecond pulse, high frequency transient overvoltage could be inevitably produced and transmit in the power conditioning system, leading to insulation and electromagnetic interference problems. In order to increase the reliability of the power conditioning system, the triggering process was analyzed and simulated by using PSPICE simulation software, a high-frequency ceramic capacitor was proposed as the suppressing device to reduce the transient overvoltage. Emulational and experimental results showed a good agreement on the waveforms of the transient overvoltage and the suppression effect of the ceramic capacitor. The amplitude of the transient overvoltage can be decreased from negative 40 to 10 kV, the suppressing device had been successful used in ShengGuang-III power conditioning system.
Similar content being viewed by others
References
M.A. Newton et al., Overview and status of the power conditioning system for the National Ignition Facility, in 2001 IEEE Pulsed Power Plasma Conference, vol.1, pp. 405–408
N.C Jaitly et al., Long life rotating arc gap coaxial switch for MEGA-AMP, Kilo-Coulomb, high action switching of multi-MJ capacitor banks, in 2005 IEEE Pulsed Power Plasma Conference, pp. 643–646
L. Jing et al., Model analysis of experiments of implosion symmetry on Shenguang-III and Shenguang-III prototype laser facilities. Acta Phys. Sin. 61(10), 105205–105205 (2012)
E.S. Fulkerson et al., NIF power conditioning system testing at LLNL, in 2001 IEEE Pulsed Power Plasma Science Conference, vol.2, pp. 1524–1527
M. Newton, D. Smith, B. Moore, Main amplifier power conditioning for the NIF[R] (LLNL National Laboratory, California, 1999)
F. Lin, J. Li, Y. Pan et al., The Whole Design of the Energy Module of SG-III. High Volt. Eng. 28(120), 26–29 (2002)
J. Hammon et al., Safety grounding approach for the National Ignition Facility power conditioning system, in 2001 IEEE Pulsed Power Plasma Science Conference, vol.2, pp. 1547–1550
L.D. Smith et al., Frequency domain target impedance method for bypass capacitor selection for power distribution systems, in Proceedings Design Con, 2006
N. Zeng et al., Marx generator of intense pulsed electron beam accelerator. High Volt. Eng. 22(2), 78–79 (1996)
L. Gang et al., Research on ground potential of Marx generator in large current switch system, in 2010 IEEE Power Modulator and High Voltage Conference, pp. 568–572
M.M. Kekez, J. Liu, A 60 Joule, 600 kV, 500 ps risetime, 60 ns pulse width Marx generator. Meas. Sci. Technol. 5(1), 1389 (1994)
K. Liu et al., Parametric design and protective strategy of energy module for SG-III high power laser. Chin. High Technol. Lett. 11(11), 96–106 (2001)
M.E. Savage, Final results from the high-current, high-action closing switch test program at Sandia National Laboratories. IEEE Trans. Plasma. Sci. 28(5), 1451–1455 (2000)
M. He et al., A high-energy spark gap switch and trigger system, in 17th IEEE High Power Particle Beams, pp. 1–4, 2008
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Chen, L., Yang, L., Liu, Y. et al. Analysis of Switching Transient Overvoltage and EMC Design of the ShengGuang-III Power Conditioning System. J Fusion Energ 35, 269–273 (2016). https://doi.org/10.1007/s10894-015-0002-9
Published:
Issue Date: