Abstract
This paper presents the transient magnetic field analysis for PF converter unit. Different short circuit conditions and different magnetic field sources are considered in the analysis. An analysis model is built for each magnetic field source first. And then a magnetic field analysis is performed for the worst short circuit condition. The analysis results presented in this paper will be a very important reference for the confirmation of EMC test level and the EMC design of instrument and control systems.
Similar content being viewed by others
References
P. Fu, I. Benfatto, et al., Review and analysis of the AC/DC converter of ITER coil power supply. in 2010 25th Annual IEEE Applied Electronics Conference and Exposition (APEC) (2010)
N. Mitchell, A. Devred et al., The ITER magnets: design and construction status. IEEE Trans. Appl. Supercond. 22(3), 4200809 (2012)
P. Libeyre, B. Bareyt et al., Electrical design requirement on the ITER coils. IEEE Trans. Appl. Supercond. 18(2), 479–482 (2008)
J. Tao, I. Benfatto, et al., ITER coil power supply and distribution system. in IEEE/NPSS 24th Symposium on Fusion Engineering (June 2011)
I. Benfatto, P.L. Mondino, et al., AC/DC converters for the ITER Poloidal field system. in 16th IEEE/NPSS Symposium on Fusion Engineering, pp. 658–661 (1995)
P. Fu, G. Gao et al., Preliminary design of the Poloidal field AC/DC converter system for the ITER coil power supply. Fusion Sci. Technol. 64(4), 741–747 (2013)
L. Jiang, Y. Yang, et al., Analysis of magnetic field environment for PF converter unit. J. Fusion Energ. (2014)
IEC61000-4-8, Electromagnetic compatibility (EMC) Part 4–8: testing and measurement techniques-power frequency magnetic field immunity test. The IEC (Jan. 2009)
D. Beltran, Test Method for ITER Equipment for Static (d.c.) Magnetic Fields, ITER Report (2013)