The present work is devoted to measure the absolute magnetic field produced by different coils in the EGYPTOR tokamak using a calibrated pickup coil. Scaling these measurements in different equations connected with the discharge currents from each supply system are performed. The pickup coil used in the present study is well calibrated with Helmholz coils at the IPP in Prague, Czech Republic. A 0.2% deviation has been found between an evaluation done in the present study and the calibration using Helmholz coils. Experimental measurements of the toroidal magnetic field are in good agreement with calculations to within 2%. Very low values of stray magnetic field components arising from TF and OH coils are recorded which proves that the compensation coils for these components are sufficient.
Similar content being viewed by others
REFERENCES
Sometani T. and Fujisawa N. (1978). Plasma Phys. 20: 1101
A. B. El Sisi and H. Hegazy, J. Fusion Energy, 22, 191, September 2003 (@2004).
Brevnov N. and Gott Yu.(2000). The Tokamak Egyptor Problem Analysis and Recommendations concerning its smooth operation. PRC, Kurchatov Institute, Russia
H. Hegazy and F. Zacek, in press.
R. Flohr, C. Gillet, J. Hackmann, G. Reinhold, G. Ritter, J. Uhlenbusch, and S. Zakaria, SFB PlasmaPhysik BOCHUM/Jülich report No. 80-01-064 (1980).
J. Wesson, TOKAMAKS (Clarendon Press Oxford, 1987).
ACKNOWLEDGMENTS
This work was a part of joint research between the IPP, Czech Academy of sciences, Czech Republic and the Egyptian Atomic Energy Authority and partially funded by the IAEA-CRP joint research using small tokamaks, contract number EGY 12937.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hegazy, H., Zacek, F. Absolute Measurements of the Magnetic Field Generated by Different Coils in the Center of EGYPTOR Tokamak. J Fusion Energ 25, 115–120 (2006). https://doi.org/10.1007/s10894-006-9011-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10894-006-9011-z