Abstract
We performed laboratory evaluation of six pulse oximeters from different manufacturers using the Fluke 2XL SpO2 simulator. The pulse oximeter probes were labeled 1 through 6 and tested using the two pre-programed preset functions of the Fluke 2XL SpO2 simulator, level 01 and level 02, for their performance in the presence of motion artifacts. The pulse oximeters were also tested at low perfusion index (PI) settings. The accuracy of the individual probes was ranked as good, mediocre, or poor based on the degree of deviation of the measured SpO2 and pulse rate (PR) by the probes from that generated by the simulator in both the presence and absence of motion artifacts and at lower PI. In preset level 01, probes numbered 1, 2, and 6 performed flawlessly, probes numbered 3, 4, and 5 performed poorly. In preset level 02, all probes performed well in the absence of motion artifacts. When probes were attached in the absence of motion, but readings were recorded after the emergence of motion artifacts, probes 1, 2, and 6 continued to perform well. However, the performance of probes 3, 4, and 5 deteriorated. When probes were attached directly in the presence of motion artifacts, probes 2 and 6 performed well, whereas all other probes performed poorly. Successively lowering the PI degraded performance of probes 3, 4, and 5 at extremely low PI. It is observed that during motion and/or low PI conditions, multiple probes see deterioration in performance.
Similar content being viewed by others
Data availability
All the data will be available on request.
Code availability
Not applicable.
References
Tierney LM Jr, Whooley MA, Saint S. Oxygen saturation: a fifth vital sign? West J Med. 1997;166(4):285–6.
Aoyagi T, Miyasaka K. Pulse oximetry: its invention, contribution to medicine, and future tasks. Anesth Analg. 2002;94(1):s1-3.
Hanning CD, Alexander-Williams JM. Pulse oximetry: a practical review. Br Med J. 1985;311:367–70.
Petterson MT, Begnoche VL, Graybeal JM. The effect of motion on pulse oximetry and its clinical significance. Anesth Analg. 2007;105(6):S78-84.
Lawless S. Crying wolf: false alarms in a pediatric intensive care unit. Crit Care Med. 1994;22:981–5.
Meredith C, Edworthy J. Are there too many alarms in the intensive care unit? An overview of the problems. J Adv Nurs. 1995;21:15–20.
Wiklund L, Hok B, Stahl K, Jordeby-Jonsson A. Postanesthesia monitoring revisited: frequency of true and false alarms from different monitoring devices. J Clin Anesth. 1994;6:182–8.
Karen KG, Thomas LH. New-generation pulse oximetery in the care of critically Ill patients. Am J Crit Care. 2005;14:7–24.
Stabile N, Reynolds K. Technological review of pulse oximeter simulators. J Clin Eng. 2002;27(4):287–97.
Cooke JE. When pulse oximeters fail: motion and low perfusion. Anesthesiology. 2000;93(3A):A554.
Shah N, Ragaswamy H, Govindugari K, Estanol L. Performance of three new-generation pulse oximeters during motion and low perfusion in volunteers. J Clin Anesth. 2012;24:385–91.
Aaron L, Feiner JR, Bickler PE, Rhodes L, Bernstein M, Lucero J. Four types of pulse oximeters accurately detect hypoxia during low perfusion and motion. Anesthesiology. 2018;128:520–30.
Funding
None.
Author information
Authors and Affiliations
Contributions
GKM: Helped in conducting the research, analyzing the data and writing the manuscript. R and SK: Helped in conducting the research and analyzing the data.
Corresponding author
Ethics declarations
Conflict of interest
All Authors declare that they have no competing interest.
Ethical approval
This is an observational study. The Postgraduate Institute of medical education & research, Chandigarh Research Ethics Committee has confirmed that no ethical approval is required.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Ganesh Kumar, M., Kaur, S. & Kumar, R. Laboratory evaluation of performance of pulse oximeters from six different manufacturers during motion artifacts produced by Fluke 2XL SpO2 simulator. J Clin Monit Comput 36, 1181–1191 (2022). https://doi.org/10.1007/s10877-021-00747-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10877-021-00747-4