Abstract
Evaluation of cardiac function during periods of stress is of key importance for the perioperative setting. Non-invasive hemodynamic monitors provide markers of cardiac function. This pilot study sought to evaluate the ability of a non-invasive hemodynamic monitor to detect cardiac stress during formal stress echocardiography testing. The primary goal was to compare the change in hemodynamic values during the pre/during/post phases of stress echocardiography testing in patients who had results negative versus positive for myocardial ischemia. Adult patients scheduled for outpatient cardiac stress testing were screened. Only patients scheduled for stress-echocardiography testing were consented. Patients with history of arrhythmias were excluded. During the testing, patients wore a cuff-based hemodynamic sensor (Nexfin system, Edwards Lifesciences). Data from the hemodynamic sensor were compared to the findings of the stress study. A total of 37 patients were enrolled, with 31 patients included for analysis. Five patients had stress studies positive for coronary ischemia. Comparison of the hemodynamic variables between patients who had a positive stress study versus negative showed a significant reduction in the percentage change in dP/dt and stroke volume from baseline (p < 0.05). This pilot study indicates that patients who have abnormal stress echocardiograms also have significantly reduced values from a noninvasive hemodynamic monitor. Further evaluation of the clinical utility of this technology, to assist in the care of patients at risk for cardiac ischemia, should be carried out.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs10877-019-00354-4/MediaObjects/10877_2019_354_Fig1_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs10877-019-00354-4/MediaObjects/10877_2019_354_Fig2_HTML.png)
Similar content being viewed by others
References
Devereaux PJ, Sessler DI. Cardiac complications in patients undergoing major noncardiac surgery. N Engl J Med. 2015;373:2258–69.
Fleisher LA, Fleischmann KE, Auerbach AD, Barnason SA, Beckman JA, Bozkurt B, Davila-Roman VG, Gerhard-Herman MD, Holly TA, Kane GC, Marine JE, Nelson MT, Spencer CC, Thompson A, Ting HH, Uretsky BF, Wijeysundera DN. 2014 ACC/AHA guideline on perioperative cardiovascular evaluation and management of patients undergoing noncardiac surgery: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation. 2014;130:2215–45.
Sheffield KM, McAdams PS, Benarroch-Gampel J, Goodwin JS, Boyd CA, Zhang D, Riall TS. Overuse of preoperative cardiac stress testing in medicare patients undergoing elective noncardiac surgery. Ann Surg. 2013;257:73–80.
Benarroch-Gampel J, Riall TS. What laboratory tests are required for ambulatory surgery? Adv Surg. 2013;47:81–98.
Ladapo JA, Blecker S, Douglas PS. Physician decision making and trends in the use of cardiac stress testing in the United States: an analysis of repeated cross-sectional data. Ann Intern Med. 2014;161:482–90.
Sigmund AE, Stevens ER, Blitz JD, Ladapo JA. Use of preoperative testing and physicians’ response to professional society guidance. JAMA Intern Med. 2015;175:1352–9.
Colla CH, Morden NE, Sequist TD, Schpero WL, Rosenthal MB. Choosing wisely: prevalence and correlates of low-value health care services in the United States. J Gen Intern Med. 2015;30:221–8.
Schwartz AL, Landon BE, Elshaug AG, Chernew ME, McWilliams JM. Measuring low-value care in medicare. JAMA Intern Med. 2014;174:1067–76.
Nicklas JY, Saugel B. Non-invasive hemodynamic monitoring for hemodynamic management in perioperative medicine. Front Med. 2017;4:209.
Bubenek-Turconi SI, Craciun M, Miclea I, Perel A. Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg. 2013;117:366–72.
Bogert LW, Wesseling KH, Schraa O, Van Lieshout EJ, de Mol BA, van Goudoever J, Westerhof BE, van Lieshout JJ. Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease. Anaesthesia. 2010;65:1119–25.
van der Spoel AG, Voogel AJ, Folkers A, Boer C, Bouwman RA. Comparison of noninvasive continuous arterial waveform analysis (Nexfin) with transthoracic Doppler echocardiography for monitoring of cardiac output. J Clin Anesth. 2012;24:304–9.
Hofhuizen C, Lansdorp B, van der Hoeven JG, Scheffer GJ, Lemson J. Validation of noninvasive pulse contour cardiac output using finger arterial pressure in cardiac surgery patients requiring fluid therapy. J Crit Care. 2014;29:161–5.
Bruce RA, Blackmon JR, Jones JW, Strait G. Exercising testing in adult normal subjects and cardiac patients. Pediatrics. 1963;32(SUPPL):742–56.
Grimshaw JM, Shirran L, Thomas R, Mowatt G, Fraser C, Bero L, Grilli R, Harvey E, Oxman A, O’Brien MA. Changing provider behavior: an overview of systematic reviews of interventions. Med Care. 2001;39:2–45.
Grise EM, Adeoye O, Lindsell C, Alwell K, Moomaw C, Kissela B, Woo D, Flaherty M, Ferioli S, Khatri P, Broderick J, Kleindorfer D. Emergency department adherence to American Heart Association guidelines for blood pressure management in acute ischemic stroke. Stroke. 2012;43:557–9.
McCormick B, Ottesen RA, Hughes ME, Javid SH, Khan SA, Mortimer J, Niland JC, Weeks JC, Edge SB. Impact of guideline changes on use or omission of radiation in the elderly with early breast cancer: practice patterns at National Comprehensive Cancer Network institutions. J Am Coll Surg. 2014;219:796–802.
Soulos PR, Yu JB, Roberts KB, Raldow AC, Herrin J, Long JB, Gross CP. Assessing the impact of a cooperative group trial on breast cancer care in the medicare population. J Clin Oncol. 2012;30:1601–7.
Acknowledgements
Briahnna Austin, BS: Department of Anesthesiology & Perioperative Care, Loma Linda University Medical Center. Roll: Biostatistician.
Funding
This project was departmentally supported.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Davinder Ramsingh, MD—Consultant and Funded Research from Edwards Lifesciences, Consultant for Fujifilm Sonosite, Funded research from General Electric on Point of Care Ultrasound and Anesthesia Delivery Systems, Funded research from Merck Pharmaceuticals, Funded research from Pacira Pharmaceuticals, Funded research from Masimo Corporation. Maxime Cannesson, MD, PhD—Ownership interest in Sironis, a company developing closed-loop systems, Consultant and Funded Research from Edwards Lifesciences, Consultant for Masimo Corp, Funded Research from National Institutes of Health: Grant Nos. R01 GM117622 (“Machine Learning of Physiological Variables to Predict Diagnose and Treat Cardiorespiratory Instability”) and R01 NR013912 (“Predicting Patient Instability Noninvasively for Nursing Care-Two [PPINNC-2]”).
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Ramsingh, D., Ma, M., Kim, J.K. et al. Feasibility evaluation of non-invasive cardiac function technology during echocardiography-based cardiac stress testing. J Clin Monit Comput 34, 655–661 (2020). https://doi.org/10.1007/s10877-019-00354-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10877-019-00354-4