Skip to main content
Log in

Limitations of near infrared spectroscopy (NIRS) in neurosurgical setting: our case experience

  • Letter to the Editor
  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

One of the primary goals of anaesthesia in neurosurgical procedures is prevention of cerebral hypoxia leading to secondary neurological injury. Cerebral oximetry detects periods of cerebral hypoxemia and allows intervention for prevention of secondary brain injury and its sequelae. This can be achieved by the use of Near Infrared Spectroscopy (NIRS). In this regard, we present two cases where erroneous values of NIRS were shown which hindered monitoring of cerebral oxygenation in the intraoperative setting. In a neurosurgical setting, the erroneous values on the operative side could be attributed to altered tissue boundary conditions resulting in a changed optical path, which is normally held as a constant in NIRS measurements. The altered tissue boundary conditions could be due to the presence of air or blood between the myocutaneous flapskull, skull-dura, dura-brain interphases. It could also be that the sensors’ penetrating depth was inadequate to compensate for the increased distance between sensor and brain tissue, thereby resulting in inaccurately higher values (> 80%).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

References

  1. Murkin JM, Arango M. Near-infrared spectroscopy as an index of brain and tissue oxygenation. Br J Anaesth. 2009;103(1):i3–13.

    Article  PubMed  Google Scholar 

  2. Kurth CD, Uher BS. Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation. Anesth Analg. 1997;84:1297–305.

    Article  CAS  PubMed  Google Scholar 

  3. Yoshitani K, Kawaguchi M, Miura N, et al. Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements. Anesthesiology. 2007;106:458–62.

    Article  PubMed  Google Scholar 

  4. Tobias JD. Cerebral oxygenation monitoring: near-infrared spectroscopy. Expert Rev Med Devices. 2006;3(2):235–43.

    Article  PubMed  Google Scholar 

  5. Young AE, Germon TJ, Barnett NJ, Manara AR, Nelson RJ. Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy. Br J Anaesth. 2000;84:38–42.

    Article  CAS  PubMed  Google Scholar 

  6. Kim W, Taw B, Yokosako S, et al. The future of non-invasive cerebral oximetry in neurosurgical procedures: a systematic review. MNI Open Res. 2018;2:3.

    Article  Google Scholar 

  7. Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012;26:279–87.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  8. Scheeren TW, Saugel B. Journal of clinical monitoring and computing 2016 end of year summary: monitoring cerebral oxygenation and autoregulation. J Clin Monit Comput. 2017;31:241–6.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

We would like to acknowledge Dr Gayatri Devi Nair MD, Transplant Fellow, Albert Einstein college of Medicine, New York, USA for editing the manuscript and for her valuable suggestions.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ajay Prasad Hrishi.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Informed consent

Informed consent was obtained from the individual participants included in the study. None of individual participants identifying information is included in this article.

Research involving human participants

All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ajayan, N., Thakkar, K., Lionel, K.R. et al. Limitations of near infrared spectroscopy (NIRS) in neurosurgical setting: our case experience. J Clin Monit Comput 33, 743–746 (2019). https://doi.org/10.1007/s10877-018-0209-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10877-018-0209-1

Keywords

Navigation