Abstract
One of the primary goals of anaesthesia in neurosurgical procedures is prevention of cerebral hypoxia leading to secondary neurological injury. Cerebral oximetry detects periods of cerebral hypoxemia and allows intervention for prevention of secondary brain injury and its sequelae. This can be achieved by the use of Near Infrared Spectroscopy (NIRS). In this regard, we present two cases where erroneous values of NIRS were shown which hindered monitoring of cerebral oxygenation in the intraoperative setting. In a neurosurgical setting, the erroneous values on the operative side could be attributed to altered tissue boundary conditions resulting in a changed optical path, which is normally held as a constant in NIRS measurements. The altered tissue boundary conditions could be due to the presence of air or blood between the myocutaneous flapskull, skull-dura, dura-brain interphases. It could also be that the sensors’ penetrating depth was inadequate to compensate for the increased distance between sensor and brain tissue, thereby resulting in inaccurately higher values (> 80%).
References
Murkin JM, Arango M. Near-infrared spectroscopy as an index of brain and tissue oxygenation. Br J Anaesth. 2009;103(1):i3–13.
Kurth CD, Uher BS. Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation. Anesth Analg. 1997;84:1297–305.
Yoshitani K, Kawaguchi M, Miura N, et al. Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements. Anesthesiology. 2007;106:458–62.
Tobias JD. Cerebral oxygenation monitoring: near-infrared spectroscopy. Expert Rev Med Devices. 2006;3(2):235–43.
Young AE, Germon TJ, Barnett NJ, Manara AR, Nelson RJ. Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy. Br J Anaesth. 2000;84:38–42.
Kim W, Taw B, Yokosako S, et al. The future of non-invasive cerebral oximetry in neurosurgical procedures: a systematic review. MNI Open Res. 2018;2:3.
Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012;26:279–87.
Scheeren TW, Saugel B. Journal of clinical monitoring and computing 2016 end of year summary: monitoring cerebral oxygenation and autoregulation. J Clin Monit Comput. 2017;31:241–6.
Acknowledgements
We would like to acknowledge Dr Gayatri Devi Nair MD, Transplant Fellow, Albert Einstein college of Medicine, New York, USA for editing the manuscript and for her valuable suggestions.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Informed consent
Informed consent was obtained from the individual participants included in the study. None of individual participants identifying information is included in this article.
Research involving human participants
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Rights and permissions
About this article
Cite this article
Ajayan, N., Thakkar, K., Lionel, K.R. et al. Limitations of near infrared spectroscopy (NIRS) in neurosurgical setting: our case experience. J Clin Monit Comput 33, 743–746 (2019). https://doi.org/10.1007/s10877-018-0209-1
Received: