Skip to main content
Log in

Comparison of Univent tube and EZ blocker in one lung ventilation; airway pressures and gas exchange

  • Original Research
  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

Univent tube (UT) and EZ-blocker were used for one-lung ventilation (OLV). UT is a single lumen tube with a small separate lumen containing a bronchial blocker. EZ-blocker differs with its unique y-shaped double-cuffed distal end. We aimed to compare these two airway devices effects on airway pressures, oxygenation, ventilation and haemodynamics during OLV. Patients undergoing elective thoracotomy for the first time were included in this prospective randomized study. Patients were divided into two groups as UT and EZ. Bronchial blockers (BB) placement time was recorded. In lateral decubitus position, airway pressures, static compliance, tidal volume (TV), respiratory rate (RR) and haemodynamic findings were recorded before inflating the BB cuff (Pre-OLV) and during OLV every 15 min. Arterial blood gas (ABG) samples were obtained before and during OLV. 70 patients were enrolled in the study. The demographic characteristics and data related to anesthesia and surgery were similar in both groups. It took longer to place EZ than UT (p = 0.02). Ppeak values were similar in both groups. Pplateau was significantly lower at the beginning of OLV (OLV15th min) and higher at the end of OLV (pre-DLV) in EZ group compared to UT (p = 0.01, p = 0.03). Cstatic were significantly higher at the beginning of OLV (OLV15th min) in EZ group compared to UT (p = 0.01). During the following measurements, Cstatic values were similar for both groups. Ventilation were achieved with similar TV and RR. ABG findings and haemodynamic variables were similar. EZ and Univent tube affected the airway pressures, oxygenation, ventilation and haemodynamic variables similarly during OLV in patients with normal respiratory function. These devices can be alternatives to each other based on clinical conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Cohen E. Back to blockers: the continued search for the ideal endobronchial blocker. Anesthesiology. 2013;118:490–03.

    Article  PubMed  Google Scholar 

  2. Inoue H, Shohtsu A, Ogawa J, Kawada S, Koide S. New device for one-lung anesthesia: endotracheal tube with movable blocker. J Thorac Cardiovasc Surg. 1982;83(6):940–41.

    CAS  PubMed  Google Scholar 

  3. Magboul M. Review and new use for the Univent tube. Internet J Anesthesiol 5(4):1–3.

  4. Mourisse J, Lerou J. Searching for the ideal endobronchial blocker. Anesthesiology. 2013;119(4):990.

    Article  PubMed  Google Scholar 

  5. Ruetzler K, Grubhofer G, Schmid W, Papp D, Nabecker S, Hutschala D, Lang G, Hager H. EZ-blocker for single lung ventilation. Br J Anaesth. 2011;106(6):896–902.

    Article  CAS  PubMed  Google Scholar 

  6. Verelst PL, Van Zundert AA. Use of the EZ-blocker for lung separation. J Clin Anesth. 2013;25(2):161–62.

    Article  PubMed  Google Scholar 

  7. Marsh HM, Bishop ML. Factors affecting pulmonary compliance and airway resistance. In: Murray MJ, Harrison BA, Mueller JT, Rose SH, Wass CT, Wedel DJ, editors. Faust’s anesthesiology review. 4th ed. Philadelphia: Elsevier Saunders; 2015, pp 28–58.

    Google Scholar 

  8. Doig GS, Simpson F. Randomization and allocation concealment: a practical guide for researchers. J Crit Care. 2005;20(2):187–91. (discussion 191–3).

    Article  PubMed  Google Scholar 

  9. Hoşten T, Topçu S. The importance of bronchoscopic anatomy for anesthesiologists. Tuberk Toraks. 2011;59(4):416–26.

    Article  PubMed  Google Scholar 

  10. Barnas GM, Stamenovic D, Lutchen KR. Lung and chest wall impedances in the dog in normal range of breathing: effects of pulmonary edema. J Appl Physiol. 1992;73(3):1040–46.

    Article  CAS  PubMed  Google Scholar 

  11. Barnas GM, Sprung J, Kahn R, Delaney PA, Agarwal M. Lung tissue and airway impedance during pulmonary edema in the normal range of breathing. J Appl Physiol. 1995;78:1889–9.

    Article  CAS  PubMed  Google Scholar 

  12. Dikmen Yalım. Solunum mekaniklerinin monitörizasyonu. Türk Yoğun Bakım Derneği Dergisi. 2006;4(2):11–3.

    Google Scholar 

  13. Michelet P, Roch A, Brousse D, D’Journo XB, Bregeon F, Lambert D, Perrin G, Papazian L, Thomas P, Carpentier JP, Auffray JP. Effects of PEEP on oxygenation and respiratory mechanics during one-lung ventilation. Br J Anaesth. 2005;95(2):267–73.

    Article  CAS  PubMed  Google Scholar 

  14. Schilling T, Kozian A, Huth C, Bühling F, Kretzschmar M, Welte T, Hachenberg T. The pulmonary immune effects of mechanical ventilation in patients undergoing thoracic surgery. Anesth Analg. 2005;101(4):957–65.

    Article  PubMed  Google Scholar 

  15. Boussarsar M, Thierry G, Jaber S, Roudot-Thoraval F, Lemaire F, Brochard L. Relationship between ventilatory settings and barotrauma in the acute respiratory distress syndrome. Intensive Care Med. 2002;28(4):406–13.

    Article  PubMed  Google Scholar 

  16. MacIntyre NR. Setting the frequence-tidal volume pattern. Respir Care. 2002;47(3):266–74.

    PubMed  Google Scholar 

  17. Benumof JL, Wahrenbrock EA. Blunted hypoxic pulmonary vasoconstriction by increased lung vascular pressures. J Appl Physiol. 1975;38:846–50.

    Article  CAS  PubMed  Google Scholar 

  18. Campos JH. An update on bronchial blockers during lung separation techniques in adults. Anesth Analg. 2003;97(5):1266–74.

    Article  PubMed  Google Scholar 

  19. Baraka A. The Univent® tube can facilitate difficult intubation in a patient undergoing thoracoscopy. J Cardiothorac Vasc Anesth. 1996;10:693–4.

    Article  CAS  PubMed  Google Scholar 

  20. Dhamee MS. One-lung ventilation in a patient with a fresh tracheostomy using the tracheostomy tube and a Univent® endobronchial blocker. J Cardiothorac Vasc Anesth. 1997;11:124–5.

    Article  CAS  PubMed  Google Scholar 

  21. Matei A, Tommaso Bizzarri F, Preveggenti V, Mancini M, Vicchio M, Agnoletti V. EZ-blocker and one-lung ventilation via tracheostomy. J Cardiothorac Vasc Anesth. 2015;29:e32–e3.

    Article  PubMed  Google Scholar 

  22. Barrick BP, Kyle RW. Conduct of anesthesia; in anesthetic management of the general thoracic surgical patient. In: Shields TW, Cicero JL, Reed CE, Feins RH, editors. General thoracic surgery. 7th ed. Philadelphia: Lippincott Williams & Wilkins; 2009. pp. 349–69.

    Google Scholar 

  23. Gayes JM. Pro: one-lung ventilation is best accomplished with the Univent endotracheal tube. J Cardiothorac Vasc Anesth. 1993;7(1):103–7.

    Article  CAS  PubMed  Google Scholar 

  24. Piccioni F, Vecchi I, Spinelli E, Previtali P, Langer M. J extraluminal EZ-blocker placement for one-lung ventilation in pediatric thoracic surgery. Cardiothorac Vasc Anesth. 2015;29(6):e71–e3.

    Article  Google Scholar 

  25. Benumof JL, Gaughan SUzuki GT. Operative lung constant positive airway pressure with the Univent bronchial blocker tube. Anesth Analg. 1992;74:406–10.

    CAS  PubMed  Google Scholar 

  26. Calenda E, Baste JM, Bergis A, Hobeika S, Peillon C. Constant positive airway pressure easily connected to an EZ blocker channel. J Clin Anesth. 2016;28:92–4.

    Article  PubMed  Google Scholar 

  27. Moritz A, Schreiner W, Schmidt J. One-lung ventilation after rapid-sequence intubation: a novel approach using an ET View tracheostomy ventilation tube for placement of an EZ-blocker without bronchoscopy. J Clin Anesth. 2016;29:48–9.

    Article  PubMed  Google Scholar 

  28. Inoue H, Shohtsu A, Ogawa J, Koide S, Kawada S. Endotracheal tube with movable blocker to prevent aspiration of intratracheal bleeding. Ann Thorac Surg. 1984;37:497–99.

    Article  CAS  PubMed  Google Scholar 

  29. Herenstein R, Russo JR, Moonka N, Capan LM. Management of one-lung anesthesia in an anticoagulated patient. Anesth Analg. 1988;67:1120.

    Article  CAS  PubMed  Google Scholar 

  30. Weng H, Xu ZY, Liu J, Ma D, Liu DS. Placement of the Univent tube without fiberoptic bronchoscope assistance. Anesth Analg. 2010;110:508–14.

    Article  PubMed  Google Scholar 

  31. Marasigan BL, Sheinbaum R, Hammer GB, Cohen E. Separation of the two lungs: double-lumen tubes, endobronchial blockers and endobronchial single-lumen tubes. In: Hagberg CA, editor Benumof and Hagberg’s airway management, 3rd ed. Philedelphia: Elsevier; 2013, p. 549.

    Chapter  Google Scholar 

  32. Campos JH. Effects on oxygenation during selective lobar versus total lung collapse with or without continuous positive airway pressure. Anesth Analg. 1997;85:583–6.

    Article  CAS  PubMed  Google Scholar 

  33. Kus A, Gurkan Y, Hosten T, Akgul AG, Solak M, Toker K. Sequential lung isolation using a bronchial blocker (EZ-blocker) for bilateral dorsal sympathectomy. J Clin Anesth. 2013;25:513–4.

    Article  PubMed  Google Scholar 

  34. Isil CT, Temel U, Oba S. Paediatric application of the EZ-blocker for thoracoscopic sympathectomy. Br J Anaesth. 2013;111:845–6.

    Article  CAS  PubMed  Google Scholar 

  35. Slinger PD, Lesiuk L. Flow resistances of disposable double-lumen, single-lumen, and Univent® tubes. J Cardiothorac Vasc Anesth. 1998;12:142–4.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

This study with project no KOÜ KAEK 2013/32 has been supported by Kocaeli University Scientific Research Projects Commission.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tülay Hoşten.

Ethics declarations

Conflict of interest

Authors have declareted no conflict of interest.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hoşten, T., Aksu, C., Kuş, A. et al. Comparison of Univent tube and EZ blocker in one lung ventilation; airway pressures and gas exchange. J Clin Monit Comput 32, 327–333 (2018). https://doi.org/10.1007/s10877-017-0028-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10877-017-0028-9

Keywords

Navigation