Using a prediction approach to assess agreement between two continuous measurements

  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

The problem of assessing agreement between two devices occurs with great frequency in the medical literature. If it can be demonstrated that a new device agrees sufficiently with a device currently in use, then the new device can be approved for general use. This work discusses how a prediction interval can be used to estimate the whether a future difference between two devices will be within acceptable limits with reasonable confidence. The method is illustrated with an example involving measurements of peak expiratory flow.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Neder JA, Stein R. A simplified strategy for the estimation of the exercise ventilatory thresholds. Med Sci Sports Exerc. 2006;38:1007–13.

    Article  PubMed  Google Scholar 

  2. McGaughran L, Voss LJ, Oliver R, Petcu M, Schaare P, Barnard JPM, et al. Rapid measurement of blood propofol levels: a proof of concept study. J Clin Monit Comput. 2006;20:109–15.

    Article  PubMed  CAS  Google Scholar 

  3. Choudhary PK, Nagaraja HN. Measuring agreement in method comparison studies—a review. In: Balakrishnan N, Kannan N, Najaraja HN, editors. Advances in ranking and section, multiple comparisons, and reliability. Boston: Birkhauser, pp. 215–44.

  4. Barnhart HX, Haber MJ, Lin LI. An overview on assessing agreement with continuous measurements. J Biopharm Stat. 2007;17:529–69.

    Article  PubMed  Google Scholar 

  5. Fleiss JL. The design and analysis of clinical experiments. New York, NY: Wiley.

  6. St. Laurent RT. Evaluating agreement with a gold standard in method comparison studies. Biometrics. 1998;54:537–45.

    Article  PubMed  CAS  Google Scholar 

  7. Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45:255–68.

    Article  PubMed  CAS  Google Scholar 

  8. Muller R, Buttner P. A critical discussion of intraclass correlation coefficients. Stat Med. 1994;13:2465–76.

    Article  PubMed  CAS  Google Scholar 

  9. Lin LI. Total deviation index for measuring individual agreement with applications in laboratory performance and bioequivalence. Stat Med. 2000;30:255–70.

    Article  Google Scholar 

  10. Lin LI, Hedayat AS, Sinha B, Yang M. Statistical methods in assessing agreement: models, issues and tools. J Am Stat Assoc. 2002;97:257–70.

    Article  Google Scholar 

  11. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;i:307–10.

    Google Scholar 

  12. Liu J, Chow SC. A two-one-sided tests procedure for assessment of individual bioequivalence. J Biopharm Stat. 1997;7:49–61.

    Article  PubMed  CAS  Google Scholar 

  13. Hamilton C, Stamey J. Using Bland–Altman to assess agreement between two medical devices—don’t forget the confidence intervals. J Clin Monit Comput. 2007;21:331–3.

    Article  PubMed  Google Scholar 

  14. Bland JM, Altman DG. Agreement between methods of measurement with multiple observation per individual. J Biopharm Stat. 2007;17:571–82.

    Article  PubMed  Google Scholar 

  15. Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135–60.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Cody Hamilton PhD.

Additional information

Hamilton C, Stamey JD. Using a prediction approach to assess agreement between two continuous measurements.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hamilton, C., Stamey, J.D. Using a prediction approach to assess agreement between two continuous measurements. J Clin Monit Comput 23, 311–314 (2009). https://doi.org/10.1007/s10877-009-9198-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10877-009-9198-4

Keywords

Navigation