Skip to main content

Advertisement

Log in

Bis Monitor Findings During Self-Hypnosis

  • Published:
Journal of Clinical Monitoring and Computing Aims and scope Submit manuscript

Abstract

Objective: We describe BIS values for a patient undergoing breast surgery under self-hypnosis in order to access the value of global surface EEG measures occurring during this process. Methods: Following verbal consent, a BISTM monitor (Aspect Medical, Newton MA) was placed and values measured while the patient performed self-hypnosis for a simple mastectomy and sentinel node biopsy. Results: Thirty-nine minutes after incision the BIS value decreased transiently to 72 followed by several other transient decreases, the lowest of which was 59. Values remained at approximately 90 throughout most of the operative period. The BIS value returned to baseline after completion of the operation. Conclusions: Our findings support the hypothesis that hypnosis is a dynamic cerebral process incorporating many changes within brain activation centers and one distinct from dissociative patterns seen under anesthesia. Current algorithms employed by the BISTM monitor add little to the management of patients utilizing hypnosis for analgesia.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Gravitz MA. Early uses of hypnosis as surgical anesthesia. Am J Clin Hypn 1988; 30: 201–208.

    CAS  PubMed  Google Scholar 

  2. Astin JA, Shapiro SL, Eisenberg DM, Forys KL. Mind-body medicine: state of the science, implications for practice. J Am Board Fam Pract 2003; 16: 131–147.

    PubMed  Google Scholar 

  3. Spiegel D, Moore R. Imagery and hypnosis in the treatment of cancer patients. Oncology 1997; 11: 1179–1189.

    CAS  PubMed  Google Scholar 

  4. Chaves JF, Dworkin SF. Hypnotic control of pain: historical perspectives and future prospects. Int J Clin Exp Hypn 1997; 45: 356–376.

    CAS  PubMed  Google Scholar 

  5. Bromm B, Lorenz J. Neurophysiological evaluation of pain. Electroencephalogr Clin Neurophysiol 1998; 107: 227–253.

    CAS  PubMed  Google Scholar 

  6. De Pascalis V, Perrone M. EEG asymmetry and heart rate during experience of hypnotic analgesia in high and low hypnotizables. Int J Psychophysiol 1996; 21: 163–175.

    Article  CAS  PubMed  Google Scholar 

  7. Ray WJ, De Pascalis V. Temporal aspects of hypnotic processes. Int J Clin Exp Hypn 2003; 51: 147–165.

    Google Scholar 

  8. Rainville P, Hofbauer RK, Paus T, Duncan GH, Bushnell MC, Price DD. Cerebral mechanisms of hypnotic induction and suggestion. J Cogn Neurosci 1999; 11: 110–125.

    Article  CAS  PubMed  Google Scholar 

  9. Rampil IJ. A primer for EEG signal processing in anesthesia. Anesthesiology 1998; 89: 980–1002.

    CAS  PubMed  Google Scholar 

  10. Shapiro BA. Bispectral Index: better information for sedation in the intensive care unit? Crit Care Med 1999; 27: 1663–1664.

    CAS  PubMed  Google Scholar 

  11. Renna M, Wigmore T, Mofeez A, Gillbe C. Biasing effect of the electromyogram on BIS: a controlled study during high-dose fentanyl induction. J Clin Monit Comput 2002; 17: 377–381.

    Article  PubMed  Google Scholar 

  12. Messner M, Beese U, Romstock J, Dinkel M, Tschaikowsky K. The bispectral index declines during neuromuscular block in fully awake persons. Anesth Analg 2003; 97: 488–491.

    CAS  PubMed  Google Scholar 

  13. Bruhn J, Bouillon TW, Shafer SL. Electromyographic activity falsely elevates the bispectral index. Anesthesiology 2000; 92: 1485–1487.

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Christopher M. Burkle MD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Burkle, C.M., Jankowski, C.J., Torsher, L.C. et al. Bis Monitor Findings During Self-Hypnosis. J Clin Monit Comput 19, 391–393 (2005). https://doi.org/10.1007/s10877-005-6539-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10877-005-6539-9

Key Words

Navigation