Abstract
Particle Image Velocimetry (PIV) is an important technique in studying blood flow in heart valves. Previous PIV studies of flow around prosthetic heart valves had different research concentrations, and thus never provided the physical flow field pictures in a complete heart cycle, which compromised their pertinence for a better understanding of the valvular mechanism. In this study, a digital PIV (DPIV) investigation was carried out with improved accuracy, to analyse the pulsatile flow field around the bi-leaflet mechanical heart valve (MHV) in a complete heart cycle. For this purpose a pulsatile flow test rig was constructed to provide the necessary in vitro test environment, and the flow field around a St. Jude size 29 bi-leaflet MHV and a similar MHV model were studied under a simulated physiological pressure waveform with flow rate of 5.2 l/min and pulse rate at 72 beats/min. A phase-locking method was applied to gate the dynamic process of valve leaflet motions. A special image-processing program was applied to eliminate optical distortion caused by the difference in refractive indexes between the blood analogue fluid and the test section. Results clearly showed that, due to the presence of the two leaflets, the valvular flow conduit was partitioned into three flow channels. In the opening process, flow in the two side channels was first to develop under the presence of the forward pressure gradient. The flow in the central channel was developed much later at about the mid-stage of the opening process. Forward flows in all three channels were observed at the late stage of the opening process. At the early closing process, a backward flow developed first in the central channel. Under the influence of the reverse pressure gradient, the flow in the central channel first appeared to be disturbed, which was then transformed into backward flow. The backward flow in the central channel was found to be the main driving factor for the leaflet rotation in the valve closing process. After the valve was fully closed, local flow activities in the proximity of the valve region persisted for a certain time before slowly dying out. In both the valve opening and closing processes, maximum velocity always appeared near the leaflet trailing edges. The flow field features revealed in the present paper improved our understanding of valve motion mechanism under physiological conditions, and this knowledge is very helpful in designing the new generation of MHVs.
Similar content being viewed by others
References
Bodnar, E., Frater, R.: Replacement Cardiac Valves. Pergamon, New York (1991)
Leefe, S.E., Gentle, C.R.: A review of the in vitro evaluation of conduit-mounted cardiac valve prostheses. Med. Eng. Phys. 17(7), 497–506 (1995)
Yoganathan, A.P., Ellis, J.T., Healy, T.M., Chatzimavroudis, G.P.: Fluid dynamic studies for the year 2000. J. Heart Valve Dis. 7, 133–139 (1998)
Healy, T.M., Fontaine, A.A., Ellis, J.T., Walton, S.P., Yoganathan, A.P.: Visualization of the hinge flow in a 5:1 scaled model of the medtronic parallel bi-leaflet heart valve prosthesis. Exp. Fluids 25, 512–518 (1998)
Chew, Y.T., Low, H.T., Lee, C.N., Kwa, S.S.: Laser anamometry measurements of steady flow past aortic valve prostheses. J. Biomech. Eng. 115, 290–298 (1993)
Browne, P., Ramuzat, A., Saxena, R., Yaganathan, A.P.: Experimental investigation of the steady flow downstream of the St. Jude bi-leaflet heart valve: a comparison between Laser Doppler velocimetry and particle image velocimetry techniques. Ann. Biomed. Eng. 28, 39–47 (2000)
Grigioni, M., Daniele, C., D’Avenio, G., Barbaro, V.: Hemodynamic performance of small-sized bi-leaflet valves: pressure drop and Laser Doppler Anemometry study comparison of three prostheses. Artif. Organs 24(12), 959–965 (2000)
Liu, J.S., Lu, P.C., Chu, S.H.: Turbulence characteristics downstream of bi-leaflet aortic valve prostheses. J. Biomech. Eng. 122, 118–124 (2000)
Kini, V., Bachmann, C., Fontaine, A., Deutsch, S., Tarbell, J.M.: Integrating particle image velocimetry and Laser Doppler velocimetry measurements of the regurgitant flow field past mechanical heart valves. Artif. Organs 25(2), 136–145 (2001)
Ringgaard, S., Botnar, R.M., Djuehuus, C., Stodkilde-Jorgensen, H., Hasenkam, J.M., Boesiger, P., Pedersen, E.M.: High-resolution assessment of velocity fields and shear stress distal to prosthetic heart valves using high field magnetic resonance imaging. J. Heart Valve Dis. 8(1), 96–103 (1999)
Durand, L., Garcia, D., Sakr, F., Save, H., Cimon, R., Pilbarot, P., Fenster, A., Dumesnil, J.: A new flow model for Doppler ultrasound study of prosthetic heart valves. J. Heart Valve Dis. 8(1), 85–95 (1999)
Raffel, M., Willert, C., Kompenhans, J.: Particle Image Velocimetry, a Practical Guide. Springer, Berlin Heidelberg New York (1998)
Brücker, C.H.: Dual-camera DPIV for flow studies past artificial heart valves. Exp. Fluids 22, 496–506 (1997)
Lim, W.L., Chew, Y.T., Chew, T.C., Low, H.T.: Steady flow dynamics of prosthetic aortic heart valves: a comparative evaluation with PIV techniques. J. Biomech. 31, 411–421 (1998)
Lim, W.L., Chew, Y.T., Chew, T.C., Low, H.T.: Pulsatile flow studies of a porcine bio-prosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage. J. Biomech. 34, 1417–1427 (2001)
Zhao, J.B., Shi, Y.B., Yeo, T.J.H., Hwang, N.H.C.: Digital particle image velocimetry investigation of the pulsatile flow around a simplified 2-D model of a bi-leaflet heart valve. J. Heart Valve Dis. 10, 239–253 (2001)
Bluestein, D., Rambod, E., Gharib, M.: Vortex shedding as a mechanism for free emboli formation in mechanical heart valves. J. Biomech. Eng. 122, 125–134 (2000)
Subramanian, A., Mu, H., Kadambi, J.R., Wernet, M.P., Brendzel, A.M., Harasaki, H.: Particle image velocimetry investigation of intra-valvular flow fields of a bi-leaflet mechanical heart valve in a pulsatile flow. J. Heart Valve Dis. 9(5), 721–731 (2000)
Manning, K.B., Kini, V., Fontaine, A., Deutsch, S., Tarbell, J.M.: Regurgitant flow field characteristics of the St. Jude bi-leaflet mechanical heart valve under physiological pulsatile flow using particle image velocimetry. Artif. Organs 27(9), 840–846 (2003)
Day, S.W., McDaniel, J.C., Wood, H.G., Allaire, P.E., Song, X., Lemire, P.P., Miles, S.D.: A prototype heartQuest ventricular assist device for particle image velocimetry measurements. Artif. Organs 26(11), 1002–1005 (2002)
Balducci, A., Grigioni, M., Querzoli, G., Romano, G.P., Daniele, C., D’Avenio, G., Barbaro, V.: Investigation of the flow field downstream of an artificial heart valve by means of PIV and PTV. Exp. Fluids 36, 204–213 (2004)
Ritchie, R.O.: Fatigue and fracture of pyrolytic carbon: a damage-tolerant approach to structural integrity and life prediction in “Ceramic” heart valve prostheses. J. Heart Valve Dis. 5 (Suppl. I), S9–S31 (1996)
Levick, J.R.: An Introduction to Cardiovascular Physiology. Arnold, London (2003)
Abdallah, S.A., Shu, S.C., Hwang, N.H.C.: Dynamic performance of heart valve prostheses and testing loop characteristics. ASAIO Trans. 29, 296–300 (1983)
Anthoine, J., Mettenleiter, M., Repellin, O., Buchlin, J.M., Candel, S.: Influence of adaptive control on vortex-driven instabilities in a scaled model of solid propellant motors. J. Sound Vib. 262, 1009–1046 (2003)
Yuan, Q., Xu, L., Ngoi, B.K.A., Yeo, T.J.H., Hwang, N.H.C.: Dynamic impact stress analysis of a bi-leaflet heart valve. J. Heart Valve Dis. 12, 102–109 (2003)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Shi, Y., Yeo, T.J.H., Zhao, Y. et al. Particle Image Velocimetry Study of Pulsatile Flow in Bi-leaflet Mechanical Heart Valves with Image Compensation Method. J Biol Phys 32, 531–551 (2006). https://doi.org/10.1007/s10867-007-9035-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10867-007-9035-2