Skip to main content

Advertisement

Log in

In vitro characterisation of calcium phosphate biomaterials loaded with lidocaine hydrochloride and morphine hydrochloride

  • Published:
Journal of Materials Science: Materials in Medicine Aims and scope Submit manuscript

Abstract

Calcium phosphate substitutes drug delivery systems are well known substances used in minor bone void-filling to release their therapeutic agent in situ. Few studies associating anaesthetics and analgesics have been performed to date. The aim of this work was to study the association of the analgesic, morphine, and the local anaesthetic, lidocaine, with a calcium deficient apatite matrix. Three types of biomaterials i.e. powders, granules and blocks, were prepared by isostatic compression, wet granulation and a combination of the two, evaluated and compared. The chemical structure of the associated therapeutic agent was studied and the characteristics of the drug delivery systems were appraised in terms of drug release. The integrity of the lidocaine hydrochloride structure, as determined by RMN 1H, was confirmed regardless of the formulation technique used (isostatic compression or wet granulation). However, analyses of morphine hydrochloride by RMN 1H revealed slight structural modifications. The association and formulation techniques that were used made it possible to obtain an in vitro release time varying from 1 to 4 days for lidocaine hydrochloride and from 1 to 3 days for morphine hydrochloride.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Vallet-Regi M, Gonzalez-Calbet JM. Calcium phosphates as substitution of bone tissues. Prog Solid State Chem. 2004;32:1–31.

    Article  CAS  Google Scholar 

  2. Obadia L, Amador G, Daculsi G, Bouler JM. Calcium-deficient apatite: influence of granule size and consolidation mode on release and in vitro activity of vancomycin. Biomaterials. 2003;24:1265–70.

    Article  CAS  PubMed  Google Scholar 

  3. Gautier H, Guicheux J, Grimandi G, Faivre-Chauvet A, Daculsi G, Merle C. In vitro influence of apatite granule specific area on human growth hormone loading and release. J Biomed Mater Res. 1998;40:606–61.

    Article  CAS  PubMed  Google Scholar 

  4. Verron E, khairoun I, Guicheux J, Bouler JM. Calcium phosphate biomaterials as bone drug delivery systems: a review. Drug Discov Today. 2010;15:547–52.

    Article  CAS  PubMed  Google Scholar 

  5. Jindong Z, Hai T, Junchao G, Bo W, Li B, Qiang WB. Evaluation of a novel osteoporotic drug delivery system in vitro: alendronate-loaded calcium phosphate cement. Orthopedics. 2010;33(8):682–3.

    Google Scholar 

  6. El-Ghannam A, Ricci K, Malkawi A, Jahed K, Vedantham K, Wyan H, Allen LD, Dréau D. A ceramic-based anticancer drug delivery system to treat breast cancer. J Mater Sci Mater Med. 2010;21(9):2701–10.

    Article  CAS  PubMed  Google Scholar 

  7. Bond DM, Rudan J, Kobus SM, Adams MA. Depot local anesthetic in polymethylmethacrylate bone cement. Clin Orthop. 2004;418:242–5.

    Article  PubMed  Google Scholar 

  8. Chen PC, Park YJ, Chang LC, Kohane DS, Bartlett RH, Langer R, Yang VC. Injectable microparticle-gel system for prolonged and localized lidocaine release. I. In vitro characterization. J Biomed Mater Res A. 2004;70(3):459–66.

    Article  PubMed  Google Scholar 

  9. Verron E, Gauthier O, Janvier P, Le Guen H, Holopherne D, Cavagna R, Bouler JM. Analgesic properties of calcium phosphate apatite loaded with bupivacaine on postoperative pain. J Biomed Mater Res B Appl Biomater. 2010;94(1):89–96.

    PubMed  Google Scholar 

  10. Obadia L, Rouillon T, Bujoli B, Daculsi G, Bouler JM. Calcium deficient apatites synthesized by ammonia hydrolysis of dicalcium phosphate dihydrate: influence of temperature, time and pressure. J Biomed Mater Res B Appl Biomater. 2007;80(1):32–42.

    PubMed  Google Scholar 

  11. Gautier H, Merle C, Auget J-L, Daculsi G. Isostatic compression, a new process for incorporating vancomycin into biphasic calcium phosphate: comparison with a classical method. Biomaterials. 2000;21:243–9.

    Article  CAS  PubMed  Google Scholar 

  12. Bourgeois B, Laboux O, Obadia L, Gauthier O, Betti E, Aguado E, Dacusi G, Bouler JM. Calcium deficient apatite: a first in vivo study concerning bone ingrowth. J Biomed Mater Res A. 2003;65(3):402–3.

    Article  CAS  PubMed  Google Scholar 

  13. Kimakhe S, Bohic S, Larrose C, Reynaud A, Pilet P, Giumelli B, Heymann D, Daculsi G. Biological activities of sustained polymyxin B release from calcium phosphate biomaterial prepared by dynamic compaction: an in vitro study. J Biomed Mater Res. 1999;47(1):18–27.

    Article  CAS  PubMed  Google Scholar 

  14. Chen PC, Kohane DS, Park YJ, Bartlett RH, Langer R, Yang VC. Injectable microparticle-gel system for prolonged and localized lidocaine release. II. In vivo anesthetic effects. J Biomed Mater Res A. 2004;70(3):459–66.

    Article  PubMed  Google Scholar 

  15. Al Malyan M, Becchi C, Nikkola L, Viitanen P, Boncinelli S, Chiellini F, Ashammakhi N. Polymer-based biodegradable drug delivery systems in pain management. J Craniofac Surg. 2006;17(2):302–13.

    Article  PubMed  Google Scholar 

  16. Paavola A, Yliruusi J, Kajimoto Y, Kalso E, Wahistrom T, Rosenberg P. Controlled release of lidocaïne from injectable gels and efficacy in rat sciatic nerve block. Pharm Res. 1995;12:1997–2000.

    Article  CAS  PubMed  Google Scholar 

  17. Sato S, Baba Y, Tajima K, Kimura T, Tsuji MH, Kohda Y, Sato Y. Prolongation of epidural anesthesia in the rabbit with the use of a biodegradable copolymer paste containing lidocaïne. Anesth Analg. 1995;80:97–101.

    Article  CAS  PubMed  Google Scholar 

  18. Reuben SS, Sklar J. Pain management in patients who undergo outpatient arthroscopic surgery of the knee. J Bone Joint Surg Am. 2000;82:1754–66.

    PubMed  Google Scholar 

  19. Arias JL, Gómez-Gallo A, Delgado AV, Ruiz MA, Kollidon SR. Colloidal particles as vehicles for oral morphine delivery in pain treatment. Colloids Surf Biointerfaces. 2009;70(2):207–12.

    Article  CAS  Google Scholar 

  20. Nakamura K, Nara E, Akiyama Y. Development of an oral sustained release drug delivery system utilizing pH-dependent swelling of carboxyvinyl polymer. J Control Release. 2006;111(3):309–15.

    Article  CAS  PubMed  Google Scholar 

  21. Hasirci V, Bonney I, Goudas LC, Shuster L, Carr DB, Wise DL. Antihyperalgesic effect of simultaneously released hydromorphone and bupivacaine from polymer fibers in the rat chronic constriction injury model. Life Sci. 2003;73(26):3323–37.

    Article  CAS  PubMed  Google Scholar 

  22. Masson P, Tonello C, Balny C. High-pressure biotechnology in medicine and pharmaceutical science. J Biomed Biotechnol. 2001;1(2):85–8.

    Article  CAS  PubMed  Google Scholar 

  23. Balny C, Hayashi R, Heremans K, Masson P. Eurotext JL, high pressure and biotechnology, vol. 224. London: Colloque INSERM; 1992.

    Google Scholar 

  24. Gautier H, Caillon J, Le Ray AM, Daculsi G, Merle C. Influence of isostatic compression on the stability of vancomycin loaded with a calcium phosphate-implantable drug delivery device. J Biomed Mater Res. 2000;52(2):308–14.

    Article  CAS  PubMed  Google Scholar 

  25. Daculsi G, Weiss P, Bouler J-M, Gauthier O, Millot F, Aguado E. Biphasic calcium phosphate/hydrosoluble polymer composites: a new concept for bone and dental substitution materials. Bone. 1999;25(2):59S–61S.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors are grateful to Pr Muriel Duflos from BioCit (UPRES EA 1155), University of Nantes, for NMR analysis; Mrs Anne-Françoise Miegeville from the Laboratoire de Thérapeutiques Cliniques et Expérimentales (EA 3826), University of Nantes, for device assistance. This work was supported by Graftys SA.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Gautier.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gautier, H., Chamblain, V., Weiss, P. et al. In vitro characterisation of calcium phosphate biomaterials loaded with lidocaine hydrochloride and morphine hydrochloride. J Mater Sci: Mater Med 21, 3141–3150 (2010). https://doi.org/10.1007/s10856-010-4172-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10856-010-4172-8

Keywords

Navigation