Abstract
Conventional superelastic orthodontic wires are arch-shaped, have the same mechanical properties all along their length and are used to correct the position of teeth. The disadvantage of these archwires is that there are different types of teeth in the mouth and different forces are therefore needed to rectify their position. The aim of this work was to laser weld several types of NiTi orthodontic wires that had different chemical compositions and superelastic properties, in order to adjust their properties to different parts of the mouth. Microstructural changes, transformation stresses and temperatures, variations in corrosion behaviour and ion release were studied in the welded wires.
Similar content being viewed by others
References
M. R. MARCOTTE, Superelastic archwires. In Biomechanics in Orthodontics, edited by M. R. Marcotte, (Ontario: Masson Editorial, 1992), p. 324
R. KROUSBROECK, G. VAN DER PERRE, E. AERNOUDT and J. C. MULIER, “Shape memory effect in biomedical devices.” In Advances in Biomaterials, vol. 3, edited by G. D. Winter, D. F. Gibbons and H. Plenk, (New York: John Wiley & Sons, 1982), p. 767
G. F. ANDREASEN and R. E. MORROW, Am. J. Orthod. 73(2) (1978) 142
G. F. ANDREASEN, Am. J. Orthod. 78(7) (1980) 528
F. J. GIL and J. A. PLANELL, J. Eng. Med. Proc. Inst. Mech. Eng. 212 (1998) 472
T. SABURI, T. TATSUMI and S. NENNO, J. Phys. Colloq C4. 12 (1982) 261–266
G. R. PURDY and J. G. PARR, Shape Memory Effect NiTi alloys. Trans. AIME 2 (1981) 23
T. YONEYAMA, H. DOI, E. KOBAYASHI and H. HAMANAKA, J. Mater. Sci: Mater. Med. 13 (2002) 947
H. H. HUANG, Y. CHIU T. LEE, S. WU, H. YANG, K. SU, C. C. HSU, Biomaterials 24 (2003) 3585
F. J. GIL, D. RODRÍGUEZ, J. A. PLANELL, M. CORTADA, L. L. GINER and S. COSTA, J. Mater. Sci: Mater. Med. 11 (2000) 287
B. O’BRIEN, W. M. CARROLL and M. J. KELLY, Biomaterials 23 (2002) 1739
R. BABOIAN, Electrochemical techniques for predicting galvanic corrosion. In Galvanic and Pitting corrosion-field and Laboratory studies. ASTM STP 576, edited by R. Baboian, R. France, J. Roew and J. F. Rynewicz, (Philadelphia: American Society for Testing and Materials, 2004), 6
F. MANSFELD, R. L. MEYERS and G. LAUER, Instrumentation for corrosion studies in low conductivity media. (2003), Technical Report Rockwell International
T. DUERING, A. PELTON and D. STÖCKEL, Mater. Sci. Eng. A273–275 (1999) 149
B. THIERRY, O. SAVADOGO, L’ H. YAHIA, J. Biomed. Mater. Res. 49 (2000) 88
Y. SHIMA, K. OTSUBO, T. YONEYAMA and K. SOMA, J. Mater. Sci: Mater. Med. 13 (2002) 197
J. GEIS-GERSTORFER, J. Dent. 22 (1994) 247
S. CANAY, M. ÖKTEMER, J. Dent. Res. 23(4) (1992) 279
L. LUCAS and J. E. LEMONS, Adv. Dent. Res. 6 (1992) 32
G. RONDELLI and B. VINCENTINI, Biomaterials 23 (2002) 639
F. J. GIL and J. A. PLANELL, J. Biomed. Mater. Res. Appl. Biomater. 48 (1999) 682
L. L. GINER, M. CORTADA, O. RUSTULLET, F. J. GIL, J. L. FERNÁNDEZ-TURIEL, D. RODRIGUEZ and J. A. PLANELL, Rev. Implantol. Orale. Implantodontie. 29 (1998) 35–41
J. LEE, L. LUCAS, J. O’Neal, J. LACEFELD and J. E. Lemons, J. Dent. Res. 64 (1985) 317
K. OZEKI, T. YUHTA, H. AOKI and Y. FUKUI, Bio. Med. Mater. Eng. 13 (2003) 271
Acknowledgements
The authors thank to CICYT the project MAT2002–04292 your financial support.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sevilla, P., Martorell, F., Libenson, C. et al. Laser welding of NiTi orthodontic archwires for selective force application. J Mater Sci: Mater Med 19, 525–529 (2008). https://doi.org/10.1007/s10856-007-0164-8