References
Kuck KH, Brugada J, Furnkranz A, Metzner A, Ouyang F, Chun KR, et al. FIRE AND ICE Investigators. Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N Engl J Med. 2016;374:2235–45.
Andrade JG, Wells GA, Deyell MW, Bennett M, Essebag V, Champagne J, et al. Cryoablation or drug therapy for initial treatment of atrial fibrillation. N Engl J Med. 2021;384:305–15.
Andrade JG, Deyell MW, Macle L, Wells GA, Bennett M, Essebag V, et al. Progression of atrial fibrillation after cryoablation or drug therapy. N Engl J Med. 2022. https://doi.org/10.1056/NEJMoa2212540.
Salghetti F, Abugattas JP, Regibus V, Iacopino S, Takarada K, Ströker E, et al. Real-time recordings in cryoballoon pulmonary veins isolation: comparison between the 25mm and the 20mm achieve catheters. J Atr Fibrillation. 2018;10:1855.
Straube F, Dorwarth U, Pongratz J, Brück B, Wankerl M, Hartl S, et al. The fourth cryoballoon generation with a shorter tip to facilitate real-time pulmonary vein potential recording: feasibility and safety results. J Cardiovasc Electrophysiol. 2019;30:918–25.
Miyazaki S, Kajiyama T, Watanabe T, Taniguchi H, Nakamura H, Hamaya R, et al. Validation of electrical ostial pulmonary vein isolation verified with a spiral inner lumen mapping catheter during second-generation cryoballoon ablation. J Cardiovasc Electrophysiol. 2017;28:870–5.
Conte G, Soejima K, de Asmundis C, Chierchia GB, Badini M, Miwa Y, et al. Value of high-resolution mapping in optimizing cryoballoon ablation of atrial fibrillation. Int J Cardiol. 2018;270:136–42.
Meissner A, Maagh P, Christoph A, Oernek A, Plehn G. Pulmonary vein potential mapping in atrial fibrillation with high density and standard spiral (lasso) catheters: a comparative study. J Arrhythm. 2017;33:192–200.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Competing interests
Dana C Johnson: none.
Erik Wissner: consultant: Medtronic.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
This comment refers to the article available at https://doi.org/10.1007/s10840-022-01384-w
Rights and permissions
About this article
Cite this article
Johnson, D.C., Wissner, E. Should voltage mapping be an integral part of the cryoballoon ablation procedure?. J Interv Card Electrophysiol 66, 517–518 (2023). https://doi.org/10.1007/s10840-022-01455-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10840-022-01455-y