Background

The Advisor™ HD Grid mapping catheter (Abbott Laboratories; Chicago, IL) allows for bipolar electrogram collection in both orthogonal and perpendicular planes, unique when compared to traditional and branch catheters. Experience in pediatric patients and congenital heart disease (CHD) is limited. The purpose of this work was to evaluate the utility and safety of the Advisor™ HD Grid mapping catheter in pediatric and CHD populations.

Methods

Retrospective review of all pediatric patients and those with CHD (regardless of age) at Children’s Hospital Colorado and University of Colorado undergoing electrophysiologic study in which the Advisor™ HD Grid mapping catheter was utilized.

Results

Sixty-five procedures in 60 patients (N = 31 female (47.6%), median age 17 years (15–24.1)) were included. Patients had CHD in 30 procedures (46.1%). Eight-eight arrhythmia substrates were mapped including atrial flutter/intra-atrial reentrant tachycardia (N = 33), focal atrial tachycardia (N = 20), isolated PVCs (N = 10), accessory pathways (N = 9), atrioventricular nodal reentrant tachycardia (N = 7), right ventricular substrate mapping (N = 7), and ventricular tachycardia (N = 2). Median time per map was 11.8 (7.5–20.1) min with 3.2 (± 1.7) maps per procedure and a median of 2634 (1767–7654) points used per map. Patients with CHD required more maps (p < 0.001) and points per map (p < 0.001). Ablation was successful in 92.4% of procedures.

Conclusions

The Advisor™ HD Grid mapping catheter is safe and effective in the pediatric and congenital heart disease population. A wide variety of arrhythmia substrates can be mapped with high point density and low mapping time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

Abbreviations

HD:

High density

CHD:

Congenital heart disease

AFL:

Atrial flutter

IART:

Intra-atrial reentrant tachycardia

FAT:

Focal atrial tachycardia

AP:

Accessory pathway

AVNRT:

Atrioventricular nodal reentrant tachycardia

PVC:

Premature ventricular contraction

VT:

Ventricular tachycardia

References

  1. Rahman M, Moore JP, Papagiannis J, et al. Utilising electroanatomic mapping during ablation in patients with CHD to reduce radiation exposure. Cardiol Young. Published online 2021. https://doi.org/10.1017/S1047951121004558.

  2. Rodgers M, Mckenna C, Palmer S, et al. Health Technology Assessment NIHR HTA Programme Www.Hta.Ac.Uk Curative catheter ablation in atrial fibrillation and typical atrial flutter: systematic review and economic evaluation. 2008;12.

  3. Nguyen M, von Alvensleben JC, Runciman M, Collins KK. Advisor high-definition HD Grid catheter for mapping accessory pathways in pediatrics. Hear Case Rep. 2020;6(12):925–9. https://doi.org/10.1016/j.hrcr.2020.09.009.

    Article  Google Scholar 

  4. Kk S, Cj D, Ja A, et al. 2018 AHA/ACC Guideline for the management of adults with congenital heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2019;139(14):E637–97. https://doi.org/10.1161/CIR.0000000000000602.

    Article  Google Scholar 

  5. Schricker AA, Winkle R, Moskovitz R, et al. Open-window mapping of accessory pathways utilizing high-density mapping. J Interv Card Electrophysiol. Published online 2020. https://doi.org/10.1007/s10840-020-00850-7.

  6. Bailin SJ, Korthas MA, Weers NJ, Hoffman CJ. Direct visualization of the slow pathway using voltage gradient mapping: a novel approach for successful ablation of atrioventricular nodal reentry tachycardia. Europace. 2011;13(8):1188–94. https://doi.org/10.1093/europace/eur112.

    Article  PubMed  Google Scholar 

  7. Tan VH, Lyu MZ, Tan PC, Wong LC, Yeo C, Wong KCK. Utility of directional high-density mapping catheter (AdvisorTM HD Grid) in complex scar-related atrial tachycardia. J Arrhythmia. 2020;36(1):180–3. https://doi.org/10.1002/joa3.12256.

    Article  Google Scholar 

  8. Yeo C, Tan VH, Wong KCK. Pulmonary vein reconnection mapping with Advisor HD Grid demonstrating local EGM which were not visible on TactiCath ablation catheter. J Arrhythmia. 2019;35(1):152–4. https://doi.org/10.1002/joa3.12144.

    Article  Google Scholar 

  9. Hong KL, Redfearn D, Chacko S, Baley J, Baranchuk A, Glover BM. High-resolution mapping of the atria using the HD Grid catheter. Hear Case Reports. 2019;5(7):351–3. https://doi.org/10.1016/j.hrcr.2018.12.012.

    Article  Google Scholar 

  10. Drago F, Calvieri C, Allegretti G, Silvetti MS. Mapping of low-voltage bridges with a high-density multipolar catheter in a child with atrioventricular nodal reentry tachycardia. Hear Case Rep. 2020;6(1):8–10. https://doi.org/10.1016/j.hrcr.2019.09.009.

    Article  Google Scholar 

  11. Takigawa M, Relan J, Kitamura T, et al. Impact of spacing and orientation on the scar threshold with a high-density grid catheter. Circ Arrhythmia Electrophysiol. 2019;12(9):e007158. https://doi.org/10.1161/CIRCEP.119.007158.

    Article  Google Scholar 

  12. Krause U, Müller MJ, Stellmacher C, Backhoff D, Schneider H, Paul T. High density mapping and catheter ablation of atrial tachycardias in adults with congenital heart disease. Clin Res Cardiol. Published online January 2, 2020. https://doi.org/10.1007/s00392-019-01592-x.

  13. Okubo K, Frontera A, Bisceglia C, et al. Grid mapping catheter for ventricular tachycardia ablation. Circ Arrhythmia Electrophysiol. 2019;12(9):e007500. https://doi.org/10.1161/CIRCEP.119.007500.

    Article  Google Scholar 

  14. Jiang R, Beaser AD, Aziz Z, Upadhyay GA, Nayak HM, Tung R. High-density grid catheter for detailed mapping of sinus rhythm and scar-related ventricular tachycardia: comparison with a linear duodecapolar catheter. JACC Clin Electrophysiol. 2020;6(3):311–23. https://doi.org/10.1016/j.jacep.2019.11.007.

    Article  PubMed  Google Scholar 

  15. Campbell T, Trivic I, Bennett RG, et al. Catheter ablation of ventricular arrhythmia guided by a high-density grid catheter. J Cardiovasc Electrophysiol. 2020;31(2):474–84. https://doi.org/10.1111/jce.14351.

    Article  PubMed  Google Scholar 

  16. Proietti R, Adlan AM, Dowd R, et al. Enhanced ventricular tachycardia substrate resolution with a novel omnipolar high-density mapping catheter: the omnimapping study. J Interv Card Electrophysiol. Published online October 9, 2019. https://doi.org/10.1007/s10840-019-00625-9.

  17. Bellmann B, Lüker J, Steven D, Sultan A. First epicardial mapping of the left ventricle using the Advisor ™ HD Grid catheter. J Interv Card Electrophysiol. 2018;53(1):103–4. https://doi.org/10.1007/s10840-018-0388-1.

    Article  PubMed  Google Scholar 

  18. Behar JM, Keating E, Lowe M. Sinus node modification utilising a novel multi electrode catheter with orthogonal wavefront mapping. Indian Pacing Electrophysiol J. 2018;18(6):231–3. https://doi.org/10.1016/j.ipej.2018.07.005.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Frisch D. Identifying a gap in a cavotricuspid isthmus flutter line using the AdvisorTM HD Grid high-density mapping catheter. J Innov Card Rhythm Manag. 2019;10(12):3919–22. https://doi.org/10.19102/icrm.2019.111202.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Drago F, Calvieri C, Allegretti G, Silvetti MS. Mapping of low-voltage bridges with a high-density multipolar catheter in a child with atrioventricular nodal reentry tachycardia. Hear Case Rep. 2020;6(1):8–10. https://doi.org/10.1016/j.hrcr.2019.09.009.

    Article  Google Scholar 

  21. Tan VH, Lyu MZ, Tan PC, Wong LC, Yeo C, Wong KCK. Utility of directional high-density mapping catheter (AdvisorTM HD Grid) in complex scar-related atrial tachycardia. J Arrhythmia. 2020;36(1):180–3. https://doi.org/10.1002/joa3.12256.

    Article  Google Scholar 

  22. Cauti FM, Rossi P, Allegretti G, Iaia L, Bianchi S. Increasing pace mapping properties in parahissian premature ventricular contraction. Novel insight from HD grid multipolar catheter. J Arrhythmia. 2019;35(1):149–51. https://doi.org/10.1002/joa3.12135.

    Article  Google Scholar 

  23. Kapel GFL, Sacher F, Dekkers OM, et al. Arrhythmogenic anatomical isthmuses identified by electroanatomical mapping are the substrate for ventricular tachycardia in repaired Tetralogy of Fallot. Eur Heart J. 2017;38(4):268–76. https://doi.org/10.1093/eurheartj/ehw202.

    Article  PubMed  Google Scholar 

  24. Sandhu A, Ruckdeschel E, Sauer WH, et al. Perioperative electrophysiology study in patients with tetralogy of Fallot undergoing pulmonary valve replacement will identify those at high risk of subsequent ventricular tachycardia. Hear Rhythm. 2018;15(5):679–85. https://doi.org/10.1016/j.hrthm.2018.01.020.

    Article  Google Scholar 

  25. Stone PA, Campbell JE, AbuRahma AF. Femoral pseudoaneurysms after percutaneous access. J Vasc Surg. 2014;60(5):1359–66. https://doi.org/10.1016/j.jvs.2014.07.035.

    Article  PubMed  Google Scholar 

  26. Stolt M, Braun-Dullaeus R, Herold J. Do not underestimate the femoral pseudoaneurysm. Vasa. 2018;47(3):177–85. https://doi.org/10.1024/0301-1526/A000691.

    Article  PubMed  Google Scholar 

  27. Erol F, Arslan S, Yüksel IÖ, et al. Determinants of iatrogenic femoral pseudoaneurysm after cardiac catheterization or percutaneous coronary intervention via the femoral artery. Turk Kardiyol Dern Ars. 2015;43(6):513–9. https://doi.org/10.5543/tkda.2015.30356.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to acknowledge the technical advisement provided by Austin Davies regarding the Advisor™ HD Grid catheter and the EnSite™ mapping system.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Johannes C. von Alvensleben.

Ethics declarations

Ethical approval

Approval for the study was obtained from the Institutional Review Board from the University of Colorado and Children’s Hospital Colorado.

Informed consent

Informed consent was not required or obtained for this study.

Conflicts of interest

No relevant disclosures or conflicts of interest are applicable for any author.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

von Alvensleben, J.C., Sandhu, A., Chang, S. et al. High-density electroanatomic mapping with grid catheter in pediatrics and congenital heart disease. J Interv Card Electrophysiol 66, 611–619 (2023). https://doi.org/10.1007/s10840-022-01364-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10840-022-01364-0

Keywords

Navigation