Subcutaneous chronic implantable defibrillation systems in humans

Abstract

The recent introduction of subcutaneous implantable cardioverter defibrillator (S-ICD) has raised attention about the potential of this technology for clinical use in daily clinical practice. We review the methods and results of the four studies conducted in humans for approval of this innovative technology for daily practice. Two studies using a temporary S-ICD system (acute human studies) were conducted to search for an appropriate lead configuration and energy requirements. For this purpose, 4 S-ICD configurations were tested in 78 patients at the time of transvenous (TV)-ICD implantation. The optimal configuration was tested in 49 more patients to comparatively assess the subcutaneous defibrillation threshold (S-DFT) versus the standard TV-ICD. Long-term implants were evaluated in 55 patients using an implanted system (chronic human study). The acute humans studies led to an optimal S-ICD configuration comprising a parasternal electrode and left anterolateral thoracic pulse generator. Both configurations successfully terminated 98% of induced ventricular fibrillation (VF), but significantly higher energy levels were required with S-ICD than with TV-ICD systems (36.6 ± 19.8 J vs. 11.1 ± 8.5 J). In the chronic study, all 137 VF episodes induced at time of implant were detected with a 98% conversion rate. Two pocket infections and four lead revisions were required during 10 ± 1 months of follow-up. During this period, survival was 98%, and 12 spontaneous ventricular tachyarrhythmias were detected and treated by the device. These data show that the S-ICD systems here consistently detected and converted VF induced at time of implant as well as sustained ventricular tachyarrhythmias occurring during follow-up (248).

This is a preview of subscription content, log in to check access.

Fig. 1
Fig. 2
Fig. 3

References

  1. 1.

    The AVID Investigators. (1997). A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The New England Journal of Medicine, 337, 1576–1583.

  2. 2.

    Connolly, S. J., Hallstrom, A. P., Cappato, R., Schron, E. B., Kuck, K. H., Zipes, D. P., Greene, H. L., Boczor, S., Domanski, M., Follmann, D., Gent, M., & Roberts, R. S. (2000). on behalf of the investigators of the AVID, CASH and CIDS studies. Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials. European Heart Journal, 21, 2071–2078.

  3. 3.

    Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., Brown, M. W., & Heo, M. (1996). for the Multicenter Automatic Defibrillator Implantation Trial Investigators. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. The New England Journal of Medicine, 335, 1933–1940.

  4. 4.

    Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002). for the Multicenter Automatic Difibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. The New England Journal of Medicine, 346, 877–883.

  5. 5.

    Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., McNulty, S. E., Clapp-Channing, N., Davidson-Ray, L. D., Fraulo, E. S., Fishbein, D. P., & Luceri, R. M. (2005). Ip JH for the SCD-HeFT Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. The New England Journal of Medicine, 352, 225–237.

  6. 6.

    Mirowski, M., Reid, P. R., Mower, M. M., Walkins, L. Jr., Platia, E. V., Griffith, L. S., & Juanteguv, J. Ml. (1984). The automatic implantable cardioverter-defibrillator. Pacing and Clinical Electrophysiology, 7, 534–540.

  7. 7.

    Brodman, R., Fisher, J. D., Furman, S., Johnston, D. R., Kim, S. G., Matos, J. A., & Waspe, L. E. (1984). Implantation of automatic cardioverter defibrillators via median sternotomy. Pacing and Clinical Electrophysiology, 7, 1363–1369.

  8. 8.

    Echt, D. S., Armstrong, K., Schmidt, P., Oyer, P. E., Stinson, E. B., & Winckle, R. A. (1985). Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator. Circulation, 71, 289–296.

  9. 9.

    Ellenbogen, K. A., Hellkamp, A. S., Wilkoff, B. L., Camunas, J. L., Love, J. C., Hadjis, T. A., Lee, K. L., & Lamas, G. A. (2003). Complications arising after implantation of DDD pacemakers: the MOST experience. The American Journal of Cardiology, 92(6), 740–741.

  10. 10.

    Parsonnet, V., Bernstein, A. D., & Lindsay, B. (1989). Pacemaker-implantation complication rates: an analysis of some contributing factors. Journal of the American College of Cardiology, 13, 917–921.

  11. 11.

    Tobin, K., Stewart, J., Westveer, D., & Frumin, H. (2000). Acute complications of permanent pacemaker implantation: their financial implications and relation to volume and operator experience. The American Journal of Cardiology, 85, 774–776.

  12. 12.

    Trigano, A. J., Taramasco, V., Paganelli, F., Gerard, R., & Levy, S. (1996). Incidence of perforation and other mechanical complications during dual active fixation. PACE, 19, 1828–1831.

  13. 13.

    Kai, H., Honma, T., & Imaizumi, T. (2001). Superior vena cava syndrome caused by multiple pacing leads. Heart, 86, 80.

  14. 14.

    Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000). Diagnosis and management of infections involving implantable electrophysiologic cardiac devices. Ann Int Med, 133, 604–608.

  15. 15.

    Grimm, W., Flores, B. F., & Marchlinski, F. E. (1993). Complications of implantable cardioverter defibrillator therapy: follow-up of 241 patients. PACE, 16, 218–222.

  16. 16.

    Pavia, S., & Wilkoff, B. (2001). The management of surgical complications of pacemakers and implantable cardioverter-defibrillators. Current Opinion in Cardiology, 16, 66–71.

  17. 17.

    Dorwarth, U., Frey, B., Dugas, M., Matis, T., Fiek, M., Schmoeckel, M., Remp, T., Durchlaub, I., Gerth, A., Steinbeck, G., & Hoffmann, E. (2003). Transvenous defibrillation leads: high incidence of failure during long-term follow-up. Journal Cardiovasc Electrophys, 14, 38–43.

  18. 18.

    Ellenbogen, K. A., Wood, M. A., Shepard, R. K., Clemo, H. F., Vaughn, T., Holloman, K., Dow, M., Leffler, J., Abeyratne, A., & Verness, D. (2003). Detection and management of an implantable cardioverter defibrillator lead failure incidence and clinical implications. Journal of the American College of Cardiology, 41, 73–80.

  19. 19.

    Kleemann, T., Becker, T., Doenges, K., Vater, M., Senges, J., Schneider, S., Saggau, W., Weisse, U., & Seidl, K. (2007). Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of > 10years. Circulation, 115, 2474–2480.

  20. 20.

    Tung, R., Zimetbaum, P., & Josephson, M. E. (2008). A critical appraisal of implantable cardioverter- defibrillator therapy for the prevention of sudden cardiac death. JACC, 52, 1111–1121.

  21. 21.

    Maisel, W. H. (2007). Transvenous implantable cardioverter defibrillator leads: the weakest link. Circulation, 115, 2461–2463.

  22. 22.

    Kitamura, S., Satomi, K., Kurita, T., Shimizu, W., Suyama, K., Aihara, N., Niwaya, K., Kobayashi, J., & Kamakura, S. (2006). Long-term follow-up of transvenous defibrillation leads: high incidence of fracture in coaxial polyurethane lead. Circulation Journal, 70, 273–277.

  23. 23.

    Lindsay BD. Task force on lead performance. Available at: http://www.hrsonline.org/News/taskforce_leadperformance.cfm?zbrandid_3077&zidType_CH&zid_813428&zsubscriberId_751606938. Accessed March 30, 2008

  24. 24.

    Multicenter Registry of Pacemaker, ICD Pulse Generator, and Lead Failures. Available at: http://www.pacerandicdregistry.com/mhif/. Accessed March 30, 2008

  25. 25.

    Jones, G. K., et al. (1995). Mechanical complications after implantation of multiple-lead nonthoracotomy defibrillator systems: implications for management and future system design. American Heart Journal, 130, 327–333.

  26. 26.

    Bardy, G. H., et al. (1993). Implantable transvenous cardioverter-defibrillators. Circulation, 87, 1152–1168.

  27. 27.

    Kron, J. (2001). Lead- and device-related complications in the antiarrhythmics versus implantable defibrillators trial. American Heart Journal, 141, 92–98.

  28. 28.

    Maisel, W. H., & Kramer, D. B. (2008). Implantable cardioverter-defibrillator lead performance. Circulation, 117, 2721–2723.

  29. 29.

    Cappato, R., & Bardy, G. H. (2005). Sub-cutaneous electrical defibrillation in canines. Journal of the American College of Cardiology, 45 Suppl, 106A. Abstract.

  30. 30.

    Bardy, G., Smith, W. M., Hood, M. A., Crozier, I. G., Melton, I. C., Jordaens, L., Theuns, D., Park, R., Wright, D. J., Connelly, D. T., Fynn, S. P., Murgatroyd, F. D., Sperzel, J., Neuzner, J., Spitzer, S., Ardashev, A. V., Oduro, A., Boersma, L., Maass, A. H., Van Gelder, I. C., Wilde, A. A., van Dessel, P. F., Knops, R. E., Barr, C. S., Lupo, P. P., Cappato, R., & Grace, A. A. (2010). An entirely subcutaneous implantable cardioverter defibrillator. New Engl Journal of Medicine, 308, 23–31.

  31. 31.

    Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., Hlatky, M. A., Newby, L. K., Page, R. L., Schoenfeld, M. H., Silka, M. J., Stevenson, L. W., & Sweeney, M. O. (2008). ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: executive summary. Heart Rhythm, 5, 935–955.

  32. 32.

    Gradaus, R., Hammel, D., Kotthoff, S., & Bocker, D. (2001). Nonthoracotomy implantable cardioverter defibrillator placement in children: use of subcutaneous array leads and abdominally placed implantable cardioverter defibrillator in children. Journal of Cardiovascular Electrophysiology, 12, 356–360.

  33. 33.

    Thogersen, A. M., Helvind, M., Jensen, T., Andersen, H., Jacobsen, J. R., & Chen, X. (2001). Implantable cardioverter defibrillator in a 4month old infant with cardiac arrest associated with a vascular heart tumor. PACE, 24, 1699–1700.

  34. 34.

    Alter, P., Waldhaus, S., Plachta, E., Moosdorf, R., & Grimm, W. (2005). Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients. Pacing and Clinical Electrophysiology, 28, 926–932.

  35. 35.

    Khairy, P., Landzberg, M. J., Gatzoulis, M. A., Mercier, L. A., Fernandes, S. M., Côte, J. M., Lavoie, J. P., Fournier, A., Guerra, P. G., Frogoudaki, A., & Walsh, E. P. (2006). Dore A for the Epicardial Versus ENdocardial pacing and Thromboembolic events (EVENT) Investigators. Transvenous pacing leads and systemic thromboemboli in patients with intracardiac shunts: a multicenter study. Circulation, 113, 2391–2397.

  36. 36.

    Sohail, M. R., Uslan, D. Z., Khan, A. H., Friedman, P. A., Hayes, D. L., Wilson, W. R., Steckelberg, J. M., Stoner, S., & Baddour, L. M. (2007). Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. Journal of the American College of Cardiology, 49, 1851–1859.

  37. 37.

    Danik, S. B., Mansour, M., Singh, J., Reddy, V. Y., Ellinor, P. T., Milan, D., & Heist, K. (2007). ‘Avila A, Ruskin JN, Mela T. Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator. Heart Rhythm, 4, 439–442.

  38. 38.

    Reynolds, M. R., Cohen, D. J., Kugelmass, A. D., Brown, P. P., Becker, E. R., Culler, S. D., & Simon, A. W. (2006). The frequency and incremental cost of major complications among medicare beneficiaries receiving implantable cardioverter-defibrillators. Journal of the American College of Cardiology, 47, 2493–2497.

  39. 39.

    Byrd, C. L., Wilkoff, B. L., Love, C. J., et al. (1999). Intravascular extraction of problematic or infected permanent pacemaker leads: 1994–1996. U.S. Extraction Database, MED Institute. Pacing and Clinical Electrophysiology, 22, 1348–1357.

Download references

Conflict of interest

Dr. Cappato and Dr. Bardy report to have intellectual properties and equities in Cameron Health Inc., the manufacturer that produces the subcutaneous ICD technology discussed in the manuscript. Dr. Crozier, Dr. Hood, Dr. Smith, Dr. Boersma and Dr. Grace report to serve as consultants for Cameron Health Inc.

Author information

Correspondence to Riccardo Cappato.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Cappato, R., Smith, W.M., Hood, M.A. et al. Subcutaneous chronic implantable defibrillation systems in humans. J Interv Card Electrophysiol 34, 325–332 (2012). https://doi.org/10.1007/s10840-012-9665-6

Download citation

Keywords

  • Subcutaneous ICD
  • Ventricular fibrillation
  • Sudden death