Accuracy of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping for real-time guided radiofrequency ablation of left atrial fibrillation—Influence of heart rhythm and radiofrequency lesions

Abstract

Circumferential radiofrequency ablation around the orifices of the pulmonary veins is a curative catheter-based therapy of paroxysmal and persistent atrial fibrillation (AF). Three-dimensional cardiac image integration is a promising new technology to visualize the complex left atrial anatomy and neighbouring structures. This study aimed to validate the accuracy of integrating multislice computed tomography (MSCT) into three-dimensional electroanatomic mapping (EAM) to guide radiofrequency catheter ablation (CA) of AF. Forty consecutive patients (34 male, mean age 56 ± 10 years) with multidrug-resistant AF underwent 16-slice MSCT 1 day before radiofrequency CA. MSCT data were processed and imported to the Carto™ EAM system. Using the CartoMerge™ Image Integration Module, the generated EAM was aligned with the MSCT images. An integrated statistical algorithm provided information about the accuracy of the fusion process. In every single patient, MSCT images could be aligned with the EAM. Mean distance between the EAM points (n = 63 ± 14) and the MSCT surface was 1.6 ± 1.2 mm with no difference between sinus rhythm versus AF (p = 0.145) and no distinction between patients in paroxysmal versus persistent/permanent AF despite a significant difference in left atrial diameters. An average of 388 ± 81 radiofrequency ablation points were taken within the procedures resulting in a mean distance of 2.3 ± 1.8 mm between the EAM points and the MSCT image after the ablation procedure. There was a significant difference of alignment accuracy before and after radiofrequency CA (p < 0.001). MSCT images can be accurately integrated into three-dimensional EAM. Pre-interventional cardiac rhythm does not influence the precision of fusion. Accuracy of fusion deteriorates after radiofrequency CA.

This is a preview of subscription content, access via your institution.

References

  1. Wolf, P. A., Mitchell, J. B., Baker, C. S., Kannel, W. B., & D’Agostino, R. B. (1998 Feb 9). Impact of atrial fibrillation on mortality, stroke, and medical costs. Archives of Internal Medicine, 158(3), 229–234.

    Article  PubMed  CAS  Google Scholar 

  2. Haissaguerre, M., Jais, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., et al. (1998). Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. New England Journal of Medicine, 339, 659–665.

    Article  PubMed  CAS  Google Scholar 

  3. Chen, S. A., Hsieh, M. H., Tai, C. T., Tsai, C. F., Prakash, V. S., Yu, W. C., et al. (1999). Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. Circulation, 100, 1879–1886.

    PubMed  CAS  Google Scholar 

  4. Haissaguerre, M., Jais, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., et al. (2000). Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci. Circulation, 101(12), 1409–1417.

    PubMed  CAS  Google Scholar 

  5. Pappone, C., Rosanio, S., Oreto, G., Tocchi, M., Gugliotta, F., Vicedomini, G., et al. (2000). Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation. Circulation, 102(21), 2562–2564.

    Google Scholar 

  6. Tops, L. F., Bax Tops, L. F., Bax, J. J., Zeppenfeld, K., Jongbloed, M. R. M., Lamb, H. J., et al. (2005). Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures. Heart Rhythm, 2, 1076–1081.

    Article  PubMed  Google Scholar 

  7. Dong, J., Calkins, H., Solomon, S. B., Lai, S., Dalal, D., Lardo, A., et al. (2006). Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations. Circulation, 113, 186–194.

    Article  PubMed  Google Scholar 

  8. Dickfeld, T., Dong, J., Solomon, S. B., Lardo, A. C., Berger, R., Halperin, H., et al. (2005). Assessment of position error of catheter mapping system (Biosense Carto V8) with CT/MR image integration capabilities. Heart Rhythm, 2, S278.

    Article  Google Scholar 

  9. Kistler, P. M., Earley, M. J., Harris, S., Abrams, D., Ellis, S., Sporton, S. C., et al. (2006 April). Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. Journal of Cardiovascular Electrophysiology, 17, 341–348.

    Article  PubMed  Google Scholar 

  10. Mantovan, R., Verlato, R., Calzolari, V., Baccillieri, S., De Leo, A., Turrini, P., et al. (2005 Dec). Comparison between anatomical and integrated approaches to atrial fibrillation ablation: Adjunctive role of electrical pulmonary vein disconnection. Journal of Cardiovascular Electrophysiology, 16(12), 1293–1297.

    Article  PubMed  Google Scholar 

  11. Gepstein, L., Wolf, T., Hayam, G., & Ben-Haim, S. A. (2001 Nov). Accurate linear radiofrequency lesions guided by a nonfluoroscopic electroanatomic mapping method during atrial fibrillation. Pacing and Clinical Electrophysiology, 24(11), 1672–1678.

    Article  PubMed  CAS  Google Scholar 

  12. Packer, D. L. (2004 Jul). Evolution of mapping and anatomic imaging of cardiac arrhythmias. Pacing and Clinical Electrophysiology, 27(7), 1026–1049.

    Article  PubMed  Google Scholar 

  13. Mlcochova, H., Tintera, J., Porod, V., Peichl, P., Cihak, R., & Kautzner, J. (2005 Oct). Magnetic resonance angiography of pulmonary veins: Implications for catheter ablation of atrial fibrillation. Pacing and Clinical Electrophysiology, 28(10), 1073–1080.

    Article  PubMed  Google Scholar 

  14. Lemola, K., Sneider, M., Desjardins, B., Case, I., Han, J., Good, E., et al. (2004 Dec 14). Computed tomographic analysis of the anatomy of the left atrium and the esophagus: Implications for left atrial catheter ablation. Circulation, 110(24), 3655–3660 (Epub 2004 Nov 29).

    Article  PubMed  Google Scholar 

  15. Pappone, C., Oral, H., Santinelli, V., Vicedomini, G., Lang, C. C., Manguso, F., et al. (2004 Jun 8). Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation. Circulation, 109(22), 2724–2726 (Epub 2004 May 24).

    Article  PubMed  Google Scholar 

  16. Piorkowski, C., Hindricks, G., Schreiber, D., Tanner, H., Weise, W., Koch, A., et al. (2006 Mar). Electroanatomic reconstruction of the left atrium, pulmonary veins, and esophagus compared with the “true anatomy” on multislice computed tomography in patients undergoing catheter ablation of atrial fibrillation. Heart Rhythm, 3(3), 317–327.

    Article  PubMed  Google Scholar 

  17. Kottkamp, H., Piorkowski, C., Tanner, H., Kobza, R., Dorszewski, A., Schirdewahn, P., et al. (2005 Feb). Topographic variability of the esophageal left atrial relation influencing ablation lines in patients with atrial fibrillation. Journal of Cardiovascular Electrophysiology, 16(2), 146–150.

    Article  PubMed  Google Scholar 

  18. Wazni, O. M., Marrouche, N. F., Martin, D. O., Verma, A., Bhargava, M., Saliba, W., et al. (2005 Jun 1). Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation: A randomized trial. JAMA, 293(21), 2634–2640.

    Article  PubMed  CAS  Google Scholar 

  19. Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2005 Mar 8). Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation, 111(9), 1100–1105 (Epub 2005 Feb 21).

    Article  PubMed  Google Scholar 

  20. Earley, M. J., Showkathali, R., Alzetani, M., Kistler, P. M., Gupta, D., Abrams, D. J., et al. (2006 Apr 13). Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: A prospective randomized trial. European Heart Journal, 27, 1223–1229.

    Article  PubMed  Google Scholar 

  21. Dickfeld, T., Calkins, H., Zviman, M., Kato, R., Meininger, G., Lickfett, L., et al. (2003 Nov 11). Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time. Circulation, 108(19), 2407–2413 (Epub 2003 Oct 20).

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Martin Martinek.

Rights and permissions

Reprints and Permissions

About this article

Cite this article

Martinek, M., Nesser, HJ., Aichinger, J. et al. Accuracy of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping for real-time guided radiofrequency ablation of left atrial fibrillation—Influence of heart rhythm and radiofrequency lesions. J Interv Card Electrophysiol 17, 85–92 (2006). https://doi.org/10.1007/s10840-006-9067-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10840-006-9067-8

Keywords

  • Atrial fibrillation
  • Radiofrequency ablation
  • Image integration
  • Computed tomography
  • CartoMerge