Skip to main content

Advertisement

Log in

Repeatability of i.Profiler for measuring wavefront aberrations in healthy eyes

  • Original Paper
  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose

To evaluate the repeatability of wavefront aberration measurements and the correlation between corneal aberration and pupil size in normal eyes using a wavefront-based autorefractor (i.ProfilerPlus; Carl Zeiss Vision, Germany).

Methods

A prospective cross-sectional study. Wavefront aberrations, including spherical aberration (SA) (Z40), coma (Z3−1, Z31), trefoil (Z3−3, Z33) and total higher-order aberrations (tHOA), were measured at different pupil diameters. The repeatability was evaluated using one-way ANOVA method, and statistical indicators including within-subject standard deviation (Sw), test–retest repeatability (TRT), and intra-class correlation coefficient (ICC). The correlations between corneal aberrations and pupil sizes were evaluated by Pearson correlation analysis.

Results

A total of 96 healthy young volunteers were enrolled. Corneal and ocular higher-order aberrations (HOA) measured by i.Profiler showed Sw < 0.01 μm, TRT < 0.10 μm, ICC > 0.90. There was a linear positive correlation between the corneal HOA and pupil size. The correlation coefficient between SA and tHOA was the largest (r = 0.996, P < 0.001).

Conclusions

The measurements of wavefront aberrations by i.Profiler are highly repeatable. Corneal HOA was significantly dependent on pupil size. SA was the most influential aberration for visual quality in this study.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

Availability of data and material

The data that support the findings of this study are available from the corresponding author upon reasonable request and after permission of Affiliated Hospital of North Sichuan Medical College.

References

  1. Kim J, Choi SH, Lim DH, Yoon GJ, Chung TY (2020) Comparison of outcomes after topography-modified refraction versus wavefront-optimized versus manifest topography-guided LASIK. BMC Ophthalmol 20:192. https://doi.org/10.1186/s12886-020-01459-0

    Article  PubMed  PubMed Central  Google Scholar 

  2. Masiwa LE, Moodley V (2020) A review of corneal imaging methods for the early diagnosis of pre-clinical Keratoconus. J Optom 13:269–275. https://doi.org/10.1016/j.optom.2019.11.001

    Article  PubMed  PubMed Central  Google Scholar 

  3. Hughes RP, Vincent SJ, Read SA, Collins MJ (2020) Higher order aberrations, refractive errodevelopment and myopia control: a review. Clin Exp Optom 103:68–85. https://doi.org/10.1111/cxo.12960

    Article  PubMed  Google Scholar 

  4. Carracedo G, Carpena-Torres C, Batres L, Serramito M, Gonzalez-Bergaz A (2020) Comparison of two wavefront autorefractors: binocular open-field versus monocular closed-field. J Ophthalmol 3:8580471. https://doi.org/10.1155/2020/8580471

    Article  Google Scholar 

  5. Garzón N, García-Montero M, López-Artero E, Poyales F, Albarrán-Diego C (2019) Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction. J Cataract Refract Surg 45:1265–1274. https://doi.org/10.1016/j.jcrs.2019.04.017 (Epub 2019 Jul 17)

    Article  PubMed  Google Scholar 

  6. Lebow KA, Campbell CE (2014) A comparison of a traditional and wavefront autorefraction. Optom Vis Sci 91:1191–1198. https://doi.org/10.1097/OPX.0000000000000378

    Article  PubMed  Google Scholar 

  7. Rauscher FG, Lange H, Yahiaoui-Doktor M, Tegetmeyer H, Blendowske R et al (2019) Agreement and repeatability of noncycloplegic and cycloplegic wavefront-based autorefraction in children. Optom Vis Sci 96:879–889. https://doi.org/10.1097/OPX.0000000000001444

    Article  PubMed  PubMed Central  Google Scholar 

  8. Mcalinden C, Khadka J, Pesudovs K (2015) Precision (repeatability and reproducibility) studies and sample-size calculation. J Cataract Refract Surg 41:2598–2604. https://doi.org/10.1016/j.jcrs.2015.06.029

    Article  PubMed  Google Scholar 

  9. Muller R, Buttner P (2010) A critical discussion of intraclass correlation coefficients. Stat Med 13:2465–2476. https://doi.org/10.1002/sim.4780132310

    Article  Google Scholar 

  10. Truckenbrod C, Meigen C, Brandt M, Vogel M, Wahl S, Jurkutat A, Kiess W (2020) Reference curves for refraction in a German cohort of healthy children and adolescents. PLoS ONE 15:0230291. https://doi.org/10.1371/journal.pone.0230291.eCollection2020

    Article  Google Scholar 

  11. Putnam NM, Vasudevan B, Juarez A, Le CT, Sam K, de Gracia PD, Hoppert A (2019) Comparing habitual and i. Script Refract BMC Ophthalmol 19:49. https://doi.org/10.1186/s12886-019-1053-x

    Article  Google Scholar 

  12. Hartwig A, Atchison DA, Radhakrishnan H (2013) Higher-order aberrations and anisometropia. Curr Eye Res 38:215–219. https://doi.org/10.3109/02713683.2012.738462 (Epub 2012 Nov 15)

    Article  PubMed  Google Scholar 

  13. Yin Y-W, Zhao Y, Xiao-ying Wu, Jiang M-Y, Xia X-b, Chen Y, Song W-T, Sheng-fa Hu, Zhou X, Young K, Wen D (2019) One-year effect of wearing orthokeratology lenses on the visual quality of juvenile myopia: a retrospective study. Peer J 7:6998. https://doi.org/10.7717/peerj.6998

    Article  Google Scholar 

  14. Naderan M, Jahanrad A, Farjadnia M (2017) Ocular, corneal, and internal aberrations in eyes with keratoconus, forme fruste keratoconus, and healthy eyes. Int Ophthalmol 38:1565–1573. https://doi.org/10.1007/s10792017-0620-5

    Article  PubMed  Google Scholar 

  15. Koh S (2018) Irregular astigmatism and higher-order aberrations in eyes with dry eye disease. Invest Ophthalmol Vis Sci 59:36–40. https://doi.org/10.1167/iovs.17-23500

    Article  Google Scholar 

  16. Hoshing A, Samant M, Bhosale S, Naik A, Naik AM (2019) Comparison of higher order aberrations in amblyopic and non-amblyopic eyes in pediatric patients with anisometropic amblyopia. Indian J Ophthalmol 67:1025–1029. https://doi.org/10.4103/ijo.IJO-1625-18

    Article  PubMed  PubMed Central  Google Scholar 

  17. Levy Y, Segal O, Avni I, Zadok D (2005) Ocular higher-order aberrations in eyes with supernormal vision. Am J Ophthalmol 139:225–228. https://doi.org/10.1016/j.ajo.2004.08.035

    Article  PubMed  Google Scholar 

  18. Randazzo A, Nizzola F, Rossetti L, Orzalesi N, Vinciguerra P (2005) Pharmacological management of night vision disturbances after refractive surgery: results of a randomized clinical trial. J Cataract Refract Surg 31:1764–1772. https://doi.org/10.1016/j.jcrs.2005.02.042

    Article  PubMed  Google Scholar 

  19. Applegate RA, Donnelly WJ, Marsack JD, Koenig DE, Pesudovs K (2007) Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging. J Opt Soc Am A Opt Image Sci Vis 24:578–587. https://doi.org/10.1364/josaa.24.000578

    Article  PubMed  PubMed Central  Google Scholar 

  20. Liao X, Haung X-Q, Lan C-J, Tan Q-Q, Wen B-W, Lin J, Tian J (2019) Comprehensive evaluation of retinal image quality in comparing different aspheric to spherical intraocular lens implants. Curr Eye Res 44:1098–1103. https://doi.org/10.1080/02713683.2019.1615512

    Article  PubMed  Google Scholar 

  21. Beiko GH, Haigis W, Steinmueller A (2007) Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values. J Cataract Refract Surg 33:848–858. https://doi.org/10.1016/j.jcrs.2007.01.035

    Article  PubMed  Google Scholar 

  22. Alió JL, Plaza-Puche AB, Piñero DP, Javaloy J, Ayala MJ (2011) Comparative analysis of the clinical outcomes with 2 multifocal intraocular lens models with rotational asymmetry. J Cataract Refract Surg 37:1605–1614. https://doi.org/10.1016/j.jcrs.2011.03.054

    Article  PubMed  Google Scholar 

  23. Venter JA, Barclay D, Pelouskova M, Bull CEL (2014) Initial experience with a new refractive rotationally asymmetric multifocal intraocular lens. J Refract Surg 30:770–776. https://doi.org/10.3928/1081597X-20141021-09

    Article  PubMed  Google Scholar 

  24. Ramón ML, Piñero DP, Pérez-Cambrodí RJ (2012) Correlation of visual performance with quality of life and intraocular aberrometric profile in patients implanted with rotationally asymmetric multifocal IOLs. J Refract Surg 28:93–99. https://doi.org/10.3928/1081597X-20111213-02

    Article  PubMed  Google Scholar 

  25. Omar IAN, Zein HA (2019) Accelerated epithelium-off corneal collagen cross-linking for keratoconus:12-month results. Clin Ophthalmol 13:2385–2394. https://doi.org/10.2147/OPTH.S232118

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

This work was supported by the Key Project of Sichuan Health and Family Planning Commission (18ZD022) and the Key Project of Nanchong City and University Cooperation (18SXHZ0492).

Funding

This work was supported by the Key Project of Sichuan Health and Family Planning Commission (18ZD022) and the Key Project of Nanchong City and University Cooperation (18SXHZ0492).

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by X.L and M.J.W. The first draft of the manuscript was written by X.L and M.J.W and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Chang-Jun Lan.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Code availability

Not applicable.

Ethical approval

All procedures performed in studies involving human participants were in accordance with the ethical standards of the Institutional Review Board of Affiliated Hospital of North Sichuan Medical College and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.

Consent to participate

Informed consent was obtained from all individual participants included in the study.

Consent for publication

Patients signed informed consent regarding publishing their data.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Xuan Liao and Mei-Jie Wang contributed equally to this work.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Liao, X., Wang, MJ., Tan, QQ. et al. Repeatability of i.Profiler for measuring wavefront aberrations in healthy eyes. Int Ophthalmol 42, 2525–2531 (2022). https://doi.org/10.1007/s10792-022-02300-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10792-022-02300-x

Keywords

Navigation