Abstract
Purpose
To create a nomogram including the translational speed of the microkeratome blade, microkeratome head size and precut tissue thickness to predict the postcut thickness for Descemet stripping automated endothelial keratoplasty to obtain the thinnest possible graft.
Methods
This prospective study incorporated 48 grafts for DSAEK from March 2017 to June 2020. Corneal tissue for DSAEK was prepared by 3 experienced physicians using the Moria Evolution 3E (Moria Inc, Antony, France) microkeratome with 400, 450 and 500 μm head sizes. Precut central corneal thickness was measured with a DGH 550 handheld pachymeter (Pachette 2), taking an average of 3 readings. The microkeratome head was selected according to precut tissue thickness. The selected microkeratome head size was 150 μm less than the donor cornea thickness. Two translational speeds were used for the microkeratome cuts. One month after surgery, the central lenticular thickness was measured with a Visante® Optical Coherence Tomography caliper (Carl Zeiss Meditec Inc, Germany). A descriptive analysis was performed.
Results
Forty-eight donor grafts were prepared. Mean graft thickness was 97.58 ± 29.84 μm (range 39–176 μm). Of the 48 samples, central graft thickness was < 120 µm (81.3%) in 39, < 100 µm (58.3%) in 28 and < 80 µm (37.5%) in 18 at 1-month follow-up. There were no statically significant differences between translational speeds.
Conclusions
A nomogram with an automated microkeratome to obtain thin grafts for DSAEK provided good graft thickness results without donor waste.
Similar content being viewed by others
References
Lee WB, Jacobs DS, Musch DC et al (2009) Descemet’s stripping endothelial keratoplasty: safety and outcomes. a report by the american academy of ophthalmology. Ophthalmology 116:1818–1830. https://doi.org/10.1016/j.ophtha.2009.06.021
Hsu M, Hereth WL, Moshirfar M (2012) Double-pass microkeratome technique for ultra-thin graft preparation in Descemet’s stripping automated endothelial keratoplasty. Clin Ophthalmol 6:425–432. https://doi.org/10.2147/OPTH.S29479
Cheung AY, Hou JH, Bedard P et al (2018) Technique for preparing ultrathin and nanothin descemet stripping automated endothelial keratoplasty tissue. Cornea 37:661–666. https://doi.org/10.1097/ICO.0000000000001510
Nahum Y, Leon P, Busin M (2015) Postoperative graft thickness obtained with single-pass microkeratome-assisted ultrathin descemet stripping automated endothelial keratoplasty. Cornea 34:1362–1364. https://doi.org/10.1097/ICO.0000000000000603
Kanavi MR, Chamani T, Kheiri B, Javadi MA (2018) Single versus double pass technique for preparation of ultrathin Descemet’s stripping automated endothelial keratoplasty tissues from donated whole eyes. Cell Tissue Bank 19:623–628. https://doi.org/10.1007/s10561-018-9712-3
Sikder S, Nordgren RN, Neravetla SR, Moshirfar M (2011) Ultra-thin donor tissue preparation for endothelial keratoplasty with a double-pass microkeratome. Am J Ophthalmol 152:202-208.e2. https://doi.org/10.1016/j.ajo.2011.01.051
Thomas PBM, Mukherjee AN, O’Donovan D, Rajan MS (2013) Preconditioned donor corneal thickness for microthin endothelial keratoplasty. Cornea 32:173–178. https://doi.org/10.1097/ICO.0b013e3182912fd2
Bucher F, Roters S, Mellein A et al (2013) OSMO-UT-DSAEK using THIN-C medium. Graefe’s Arch Clin Exp Ophthalmol 251:2181–2185. https://doi.org/10.1007/s00417-013-2434-0
Romano V, Steger B, Myneni J et al (2017) Preparation of ultrathin grafts for Descemet-stripping endothelial keratoplasty with a single microkeratome pass. J Cataract Refract Surg 43:12–15. https://doi.org/10.1016/j.jcrs.2016.12.009
Murta JN, Rosa AM, Quadrado MJC et al (2013) Combined use of a femtosecond laser and a microkeratome in obtaining thin grafts for Descemet stripping automated endothelial keratoplasty: An eye bank study. Eur J Ophthalmol 23:584–589. https://doi.org/10.5301/ejo.5000273
Thannhäuser CL, Palka K, Herbst H et al (2014) Mikrokeratom- und excimer-laser-gestützte endotheliale keratoplastik (MELEK). Klin Monbl Augenheilkd 231:1008–1011. https://doi.org/10.1055/s-0034-1383094
Romano V, Steger B, Chen JY et al (2015) Reliability of the effect of artificial anterior chamber pressure and corneal drying on corneal graft thickness. Cornea 34:866–869. https://doi.org/10.1097/ICO.0000000000000451
Villarrubia A, Cano-Ortiz A (2015) Development of a nomogram to achieve ultrathin donor corneal disks for Descemet-stripping automated endothelial keratoplasty. J Cataract Refract Surg 41:146–151. https://doi.org/10.1016/j.jcrs.2014.04.036
Chen ES, Terry MA, Shamie N et al (2008) Precut tissue in descemet’s stripping automated endothelial keratoplasty. donor characteristics and early postoperative complications. Ophthalmology 115:497–502. https://doi.org/10.1016/j.ophtha.2007.11.032
Farbman NH, Li Y, Ling J et al (2019) A simple 60-second swelling technique for more consistent ultrathin DSAEK graft preparation. Cornea 38:1209–1214. https://doi.org/10.1097/ICO.0000000000002048
Deng SX, Lee WB, Hammersmith KM et al (2018) Descemet membrane endothelial keratoplasty: safety and outcomes: a report by the american academy of ophthalmology. Ophthalmology 125:295–310. https://doi.org/10.1016/j.ophtha.2017.08.015
Bae SS, Menninga I, Hoshino R et al (2018) Nomogram to predict graft thickness in descemet stripping automated endothelial keratoplasty: an eye bank study. Cornea 37:687–690. https://doi.org/10.1097/ICO.0000000000001524
Madi S, Leon P, Nahum Y et al (2019) Five-year outcomes of ultrathin descemet stripping automated endothelial keratoplasty. Cornea 38:1192–1197. https://doi.org/10.1097/ICO.0000000000001999
Pogorelov P, Cursiefen C, Bachmann BO, Kruse FE (2009) Changes in donor corneal lenticule thickness after Descemet’s stripping automated endothelial keratoplasty (DSAEK) with organ-cultured corneas. Br J Ophthalmol 93:825–829. https://doi.org/10.1136/bjo.2008.147389
Dimitry MES, Lewis AD, Zacharaki F et al (2017) Simple single-pass technique for ultrathin descemet stripping automated endothelial keratoplasty: a pilot study. Cornea 36:1178–1183. https://doi.org/10.1097/ICO.0000000000001273
Busin M, Madi S, Santorum P et al (2013) Ultrathin descemet’s stripping automated endothelial keratoplasty with the microkeratome double-pass technique: two-year outcomes. Ophthalmology 120:1186–1194. https://doi.org/10.1016/j.ophtha.2012.11.030
Roberts HW, Mukherjee A, Aichner H, Rajan MS (2015) Visual outcomes and graft thickness in microthin DSAEK - one-year results. Cornea 34:1345–1350. https://doi.org/10.1097/ICO.0000000000000596
Ho JW, Jung H, Chau M et al (2020) Comparisons of cornea cold, a new corneal storage medium, and optisol-GS. Cornea 39:1017–1019. https://doi.org/10.1097/ICO.0000000000002330
Saunier V, Robinet Perrin A, Costet C, Touboul D (2016) Reproductibilité de la simple découpe pour la préparation des DSAEK avec le microkératome MORIA à usage unique. J Fr Ophtalmol 39:780–785. https://doi.org/10.1016/j.jfo.2016.06.004
Waite A, Davidson R, Taravella MJ (2013) Descemet-stripping automated endothelial keratoplasty donor tissue preparation using the double-pass microkeratome technique. J Cataract Refract Surg 39:446–450. https://doi.org/10.1016/j.jcrs.2012.10.048
Funding
This study was not funded by any institution or organization or any other funding body.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
All authors declare no conflict of interest with any of the stated materials in the study.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Sánchez-Ventosa, Á., Cano-Ortiz, A., Morales, P. et al. Nomogram for single-pass automated microkeratome graft preparation for ultrathin Descemet stripping automated endothelial keratoplasty. Int Ophthalmol 42, 989–995 (2022). https://doi.org/10.1007/s10792-021-02082-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-021-02082-8