Abstract
Purpose
This paper introduces a surgical technique for the sutureless management of zonular dialysis greater than 120° using a capsular tension segment (CTS) or a modified capsular tension ring (m-CTR; CTR with suturing eyelets) and a haptic removed from a 3-piece polypropylene IOL.
Methods
A CTR is used as normal. Cataract removal is followed by connection of the CTS or m-CTR to the single haptic and created using heat to make a flange in one haptic’s extremity. The other extremity is placed in the CTS or m-CTR’s central hole. The CTS or m-CTR/flanged-haptic complex is introduced into the capsular bag and aligned with the weakest zonular quadrant. A 30-gauge needle guides the externalization of the free haptic extremity through the adjacent pars plana and creates a flange on the second haptic tip permitting intrascleral fixation of the CTS or m-CTR.
Results
The result is a successful IOL implantation with a sutureless technique.
Conclusions
This double-flanged m-CTR/CTS technique allows suture-free option for managing zonular weakness or dialysis while performing cataract surgery.
References
Tribus C, Alge CS, Haritoglou C, Lackerbauer C, Kampik A, Mueller A, Priglinger SG (2007) Indications and clinical outcome of capsular tension ring (CTR) implantation: a review of 9528 cataract surgeries. Clin Ophthalmol 1(1):65–69
Yamane S, Inoue M, Arakawa A, Kadonosono K (2014) Sutureless 27-gauge needle guided intrascleral intraocular lens implantation with lamellar scleral dissection. Ophthalmology 121:61–66
Gimbel HV, Condon GP, Kohnen T, Olson RJ, Halkiadakis I (2005) Late in-the-bag intraocular lens dislocation: incidence, prevention, and management. J Cataract Refract Surg 31:2193–2204
Price MO, Price FW, Werner L, Berlie C, Mamalis N (2005) Late dislocation of scleral-sutured posterior chamber intraocular lenses. J Cataract Refract Surg 31:1320–1326
Yamane S (2016) Transconjunctival intrascleral IOL fixation with double-needle technique, presented at the ASCRS symposium on cataract, IOL and refractive surgery, New Orleans, USA
Masket S, Osher RH (2002) Late complications with intraocular lens dislocation after capsulorhexis in pseudoexfoliation syndrome. J Cataract Refract Surg 28:1481–1484
Jehan FS, Mamalis N, Crandall AS (2001) Spontaneous late dislocation of intraocular lens within the capsular bag in pseudoexfoliation patients. Ophthalmology 108:1727–1731
Lorente R, de Rojas V, Vazquez de Parga P, Moreno C, Landaluce ML, Domınguez R, Lorente B (2010) Management of late spontaneous in-the-bag intraocular lens dislocation: retrospective analysis of 45 cases. J Cataract Refract Surg 36:1270–1282
Lichtinger A, Kim P, Yeung SN, Amiran MD, Alangh M, Rootman DS (2013) Secondary intraocular lens interventions: predisposing factors, indications and coincident procedures. Int Ophthalmol 33:111–115
Hayashi K, Hirata A, Hayashi H (2007) Possible predisposing factors for in-the-bag and out-of-the-bag intraocular lens dislocation and outcomes of intraocular lens exchange surgery. Ophthalmology 114:969–975
Michaeli A, Soiberman U, Loewenstein A (2012) Outcome of iris fixation of subluxated intraocular lenses. Graefes Arch Clin Exp Ophthalmol 250:1327–1332
Gross JG, Kokame GT, Weinberg DV, for the Dislocated In-The Bag Intraocular Lens Study Group (2004) In-the-bag intraocular lens dislocation. Am J Ophthalmol 137:630–635
Kim SS, Smiddy WE, Feuer W, Shi W (2008) Management of dislocated intraocular lenses. Ophthalmology 115:1699–1704
Praveen MR, Vasavada AR, Singh R (2003) Phacoemulsification in subluxated cataract. Indian J Ophthalmol 51(2):147–154
Rai G, Sahai A, Kumar PR (2015) Outcome of capsular tension ring (CTR) implant in complicated cataracts. J Clin Diagn Res 9(12):NC05–NC07
Hara T, Hara T, Yamada Y (1991) “Equator ring” for maintenance of the completely circular contour of the capsular bag equator after cataract removal. Ophthalmic Surg 22:358–359
Cionni RJ, Osher RH (1998) Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation. J Cataract Refract Surg 24:1299–1306
Nagamoto T, Bissen-Miyajima H (1994) A ring to support the capsular bag after continuous curvilinear capsulorhexis. J Cataract Refract Surg 20:417–420
Henderson BA, Kim JY (2007) Modified capsular tension ring for cortical removal after implantation. J Cataract Refract Surg 33:1688–1690
Dick HB (2005) Closed foldable capsular rings. J Cataract Refract Surg 31:467–471
Nishi O, Nishi K, Menapace R, Akura J (2001) Capsular bending ring to prevent posterior capsule opacification: 2 year follow-up. J Cataract Refract Surg 27:1359–1365
Jacob S, Agarwal A, Agarwal A, Narasimhan S, Kumar DA (2014) Glued capsular hook: technique for fibrin glue–assisted sutureless transscleral fixation of the capsular bag in subluxated cataracts and intraocular lenses. J Cataract Refract Surg 40:1958–1965
Kara N (2015) A modified glued transscleral intraocular lens implantation: suture-assisted sutureless technique. J Refract Surg 31(7):488–491
Lang Y, Fineberg E, Garzozi HJ (2001) Vitrectomy to remove a posteriorly dislocated endocapsular tension ring. J Cataract Refract Surg 27:474–476
Bhattacharjee H, Bhattacharjee K, Das D, Jain PK, Chakraborty D, Deka S (2004) Management of a posteriorly dislocated endocapsular tension ring and a foldable acrylic intraocular lens. J Cataract Refract Surg 30:243–246
Lim MCC, Jap AHE, Wong EYM (2006) Surgical management of late dislocated lens capsular bag with intraocular lens and endocapsular tension ring. J Cataract Refract Surg 32:533–535
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Financial disclosure
The corresponding author has a pending patent in PCT to produce a CTR/CTS device that can be used in this technique. There are no other financial interests or conflicts to disclose for any of the authors.
Research involving human participants
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Patient consent
The patient has consented to the submission of the case report to the journal.
Electronic supplementary material
Below is the link to the electronic supplementary material.
10792_2017_746_MOESM1_ESM.mp4
A haptic is removed from a 3-piece IOL, and one end of the haptic is heated and shaped into a flange. This haptic is connected to a CTS or m-CTR. A standard CTR is inserted to redistribute capsular forces, expand the fornix, and decrease flaccidity of the posterior capsule. Phacoemulsification and cortex aspiration are performed to remove the cataract. The other end haptic is placed in the center hole of the CTS or m-CTR, forming a CTS or m-CTR/flanged-haptic complex. This complex is introduced into the capsular bag and aligned with the weakest zonular quadrant. A 23-gauge micro-forceps is used to place the flanged-haptic end into the eye of a 30-gauge guide needle. The threaded needle is used as an external guide of the haptic’s end within the sclera. The second haptic tip is then be bent into a flange (using heat). IOL implantation is performed following standard protocol. Finally, external flanged haptic is then inserted into the sclera. Supplementary material 1 (MP4 21902 kb)
Rights and permissions
About this article
Cite this article
Canabrava, S., Bernardino, L., Batisteli, T. et al. Double-flanged-haptic and capsular tension ring or segment for sutureless fixation in zonular instability. Int Ophthalmol 38, 2653–2662 (2018). https://doi.org/10.1007/s10792-017-0746-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-017-0746-5