Abstract
Purpose
The purpose of this study was to analyze the reliability of the fixation preference test (FPT) in the detection of amblyopia, and to determine interexaminer agreement.
Methods
Eighty patients whose visual acuity could be tested objectively and had a horizontal misalignment of more than 10 prism diopters were enrolled. The best corrected visual acuity (BCVA) and orthoptic findings were all recorded. Non-preferred eye in primary position and fixation preference grade were assessed independently by two masked experienced examiners. The primary outcome measures were reliability of FPT in terms of its correlation with BCVA and interexaminer agreement.
Results
There was no significant correlation between fixation preference grades and interocular visual acuity difference as well as the type and amount of deviation, the presence of fusion, stereopsis, anisometropia, and previous strabismus surgery for none of the examiners (p > 0.05 for all). Sensitivity was 52.0% for examiner 1 and 54.0% for examiner 2 while specificity was 50.0 and 46.7%, respectively. Interexaminer agreement was 76.7% (p < 0.001) for all patients.
Conclusions
FPT is widely used in children particularly when the visual acuity cannot be determined in an objective manner. The test may not be accurate and reliable in the detection of amblyopia and also in predicting the visual acuity difference between both eyes, even though it was found to show a high degree of agreement between examiners. In conclusion, it should be kept in mind that the reliability of FPT may be limited and the results should be interpreted with caution and be supported by other tests.
Similar content being viewed by others
References
von Noorden GK, Campos E (2002) Binocular vision and ocular motility, 6th edn. Mosby, St Louis
Holmes JM, Clarke MP (2006) Amblyopia. Lancet 367:1343–1351
Zipf RF (1976) Binocular fixation pattern. Arch Ophthalmol 94:401–405
Sener EC, Mocan MC, Gedik S, Ergin A, Sanaç AS (2002) The reliability of grading the fixation preference test for the assessment of interocular visual acuity differences in patients with strabismus. J AAPOS 6:191–194
Knapp P, Moore S (1962) Diagnostic procedures in an orthoptic evaluation. Am Orthopt J 12:63–69
Laws D, Noonan CP, Ward A, Chandna A (2000) Binocular fixation pattern and visual acuity in children with strabismic amblyopia. J Pediatr Ophthalmol Strabismus 37:24–28
Attarzadeh A, Hoseinirad A, Farvardin M, Talebnejad MR, Alipour A (2009) Reliability of fixation preference for detecting amblyopia in strabismic patients. J Ophthalmic Vis Res 4:160–163
Wright KW, Edelman PM, Walonker F, Yiu S (1986) Reliability of fixation preference testing in diagnosing amblyopia. Arch Ophthalmol 104:549–553
Hakim OM (2007) Association between fixation preference testing and strabismic pseudoamblyopia. J Pediatr Ophthalmol Strabismus 44:174–177
Friedman DS, Katz J, Repka MX et al (2008) Lack of concordance between fixation preference and HOTV optotype visual acuity in preschool children: the Baltimore Pediatric Eye Disease Study. Ophthalmology 115:1796–1799
Cotter SA, Tarczy-Hornoch K, Song E, Multi-Ethnic Pediatric Eye Disease Study Group et al (2009) Fixation preference and visual acuity testing in a population-based cohort of preschool children with amblyopia risk factors. Ophthalmology 116:145–153
American Academy of Ophthalmology (2007-2008) Amblyopia. In: Basic and clinical science course: pediatric ophthalmology and strabismus. The Academy, San Francisco, pp 67–75
Wallace DK (2010) Fixation preference tests for amblyopia: invaluable, useless, or somewhere in the middle? J AAPOS 14:201–202
Procianoy L, Procianoy E (2010) The accuracy of binocular fixation preference for the diagnosis of strabismic amblyopia. J AAPOS 14:205–210
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers’ bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.
Ethical approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Patients were recruited upon approval of the institutional review board/ ethics 21 committee. The authors adhered to the tenets of the Declaration of Helsinki.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
About this article
Cite this article
Erkan Turan, K., Taylan Sekeroglu, H., Karahan, S. et al. Fixation preference test: reliability for the detection of amblyopia in patients with strabismus and interexaminer agreement. Int Ophthalmol 37, 1305–1310 (2017). https://doi.org/10.1007/s10792-016-0403-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-016-0403-4