Abstract
Comparison of peristaltic and Venturi pumps in bimanual microincision phacoemulsification on the success of the cataract surgery by using sleeveless phaco tip. Bimanual microincision phacoemulsification was done in 49 eyes using a 1.4-mm temporal clear corneal incision. A peristaltic pump was used in 23 eyes, and a Venturi pump was used in 26 eyes for phacoemulsification. Intraoperative complications, anterior chamber stability, and mean duration of surgery were recorded. Duration of surgery was shorter in the Venturi pump group. Anterior chamber stability could not be established in 17 eyes in the peristaltic pump group; it was established in all eyes in the Venturi pump group. Corneal burns were observed in two eyes in the peristaltic pump group and no eyes in the Venturi pump group. Use of a Venturi pump system and a vented gas-forced infusion system can significantly shorten surgery time and reduce risk of thermal burns.
Similar content being viewed by others
References
Tsuneoka H, Hayama A, Takahama M (2003) Ultrasmall-incision bimanual phacoemulsification and AcrySof SA30AL implantation through a 2.2 mm incision. J Cataract Refract Surg 29:1070–1076. doi:10.1016/S0886-3350(03)00076-2
Tsuneoka H, Shiba T, Takahashi Y (2001) Feasibility of ultrasound cataract surgery with a 1.4 mm incision. J Cataract Refract Surg 27:934–940. doi:10.1016/S0886-3350(01)00822-7
Tsuneoka H, Shiba T, Takahashi Y (2002) Ultrasonic phacoemulsification using a 1.4 mm incision: clinical results. J Cataract Refract Surg 28:81–86. doi:10.1016/S0886-3350(01)01235-4
Kanellopoulos AJ, Dodick JM, Brauweiler P et al (1999) Dodick photolysis for cataract surgery: early experience with the Q-switched neodymium: YAG laser in 100 consecutive patients. Ophthalmology 106:2197–2202. doi:10.1016/S0161-6420(99)90505-5
Pérez-Arteaga A (2004) Anterior vented gas forced infusion system of the accurus surgical system in Phakonit. J Cataract Refract Surg 30:933–935. doi:10.1016/j.jcrs.2004.02.062
Agarwal A, Agarwal S, Agarwal A (2002) Phakonit and laser phakonit-cataract surgery through a 0.9 mm-incision. In: Agarwal S, Agarwal A, Agarwal A (eds) Phako, phakonit, & laser phako: a quest for the best. Highlights Ophthalmol, Panama, pp 327–334
Buratto L, Werner L, Zanini M et al (2005) Phacoemulsification principles and techniques, 2nd edn. Thorofare, New Jersy, Slack Inc, pp 41–44
Allen D (2004) The mechanical and hydrodynamic aspects of phacoemulsification. In: Yanoff M, Duker JS (eds) Ophthalmology, 2nd edn. 11830 Westline Industrial Drive, St.Louis, pp 1–3 Section:4, Chapter:46
Agarwal A, Agarwal S, Agarwal A (1999) Phakonit and laser phakonit: lens removal through a 0.9-mm incision. In: Agarwal S, Agarwal A, Sachdev MS et al (eds) Phaco-emulsification, laser cataract surgery and foldable intraocular lenses. Jaypee Brothers, New Delhi, pp 204–216
Tsuneoka H, Shiba T, Takahashi Y (2002) Ultrasonic phacoemulsification using a 1.4 mm incision: clinical results. J Cataract Refract Surg 28:81–86. doi:10.1016/S0886-3350(01)01235-4
Bissen-Miyajima H, Shimmura S, Tsubota K (1999) Thermal effect on corneal incisions with different phacoemulsification ultrasonic tips. J Cataract Refract Surg 25:60–64. doi:10.1016/S0886-3350(99)80012-1
Mackool RJ (1994) Preventing incision burn during phacoemulsification. J Cataract Refract Surg 20:367–368
Cionni RJ, Osher RH (1995) Intraoperative complications of phacoemulsification surgery. In: Steinert RF (ed) Cataract surgery: technique, complications & management. WB Saunders, Philadelphia PA, p 335
Nagahara M, Shimizu K (1994) Temperature change in the corneal stroma around the wound during phacoemulsification. Folia Ophthalmol Jpn 45:129–132 in Japanese
Yamagami S (1996) Wound temperature in pig eyes during phacoemulsification, with or without pulse mode. Folia Ophthalmol Jpn 47:189–191 in Japanese
Hara T, Hara T (1987) Clinical results of endocapsular phacoemulsification and complete in-the-bag intraocular lens fixation. J Cataract Refract Surg 13:279–286
Agarwal A, Agarwal A, Agarwal S (2001) Phakonit: phacoemulsification through a 0.9 mm corneal incision. J Cataract Refract Surg 27:1548–1552. doi:10.1016/S0886-3350(01)00922-1
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Karaguzel, H., Karalezlı, A. & Aslan, B.S. Comparison of peristaltic and Venturi pumps in bimanual microincisional cataract surgery. Int Ophthalmol 29, 471–475 (2009). https://doi.org/10.1007/s10792-008-9267-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-008-9267-6