Effect of topical corneal anaesthesia on ocular response analyzer parameters: pilot study

  • Original Paper
  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose The effect of topical corneal anaesthesia on corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal compensated IOP (IOPcc) was measured by ocular response analyzer (ORA). Design Observational, cross-sectional study. Method We examined both eyes of 23 healthy volunteers. Patients with external eye disease, previous refractive surgery, contact lenses or topical medication were excluded. ORA parameters were first measured in both eyes. Oxybuprocaïne 0.4% eye drop was instilled in the right eyes (RE) and physiologic saline in the left eyes (LE) as a control to rule out the lubrication effect. After 2 min, the ORA measurements were performed again. Goldmann applanation tonometry (GAT) was finally done. Data are expressed as mean ± standard deviation (SD). The medians of the four CH, CRF, IOPg, and IOPcc values measured before and after instillation were compared by using Wilcoxon signed ranks tests for RE and LE. Results The mean age was 39.5 ± 11.6 years. The mean GAT was 13.1 ± 2.5 mmHg for RE and 12.8 ± 2.5 mmHg for LE. In the RE, the respective values for the two sequences were IOPcc = 15.6 ± 2.6 mmHg and 15 ± 2.8 mmHg (P = 0.036); IOPg = 15.3 ± 3.3 mmHg and 15.4 ± 3.5 mmHg (P = 0.806); CH = 11 ± 1.3 mmHg and 11.1 ± 1.4 mmHg (P = 0.563); CRF = 11.1 ± 1.8 mmHg and 10.9 ± 1.9 mmHg (P = 0.053). In the LE, the respective values for the two sequences were IOPcc = 15.4 ± 2.6 mmHg and 15.6 ± 2.8 mmHg (P = 0.903); IOPg = 15.5 ± 3.5 mmHg and 15.4 ± 3.4 mmHg (P = 0.208); CH = 10.8 ± 1.4 mmHg and 10.7 ± 1.7 mmHg (P = 0.494); CRF = 10.7 ± 1.8 mmHg and 10.7 ± 2.2 mmHg (P = 0.626). Conclusion Two minutes after instillation, topical corneal anaesthetic slightly decreases IOPcc and also—but not statistically significantly—CRF. We did not find any statistical significant difference in CH or IOPg before and after topical corneal anaesthesia. Further investigation with more patients should be advised.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Luce DA (2005) Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 31:156–162

    Article  PubMed  Google Scholar 

  2. Congdon NG, Broman AT, Bandeen-Roche K, Grover D, Quigley HA (2006) Central corneal thickness and corneal hysteresis associated with glaucoma damage. Am J Ophthalmol 141:868–875

    Article  PubMed  Google Scholar 

  3. Medeiros FA, Weinreb RN (2006) Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma 15:364–370

    Article  PubMed  Google Scholar 

  4. Kotecha A, Elsheikh A, Roberts CR, Zhu H, Garway-Heath DF (2006) Corneal thickness and age-related biomechanical properties of the cornea measured with the Ocular Response Analyzer. Invest Ophthalmol Vis Sci 47:5337–5347

    Article  PubMed  Google Scholar 

  5. Bland JM, Altman DG (1996) Statistics notes: measurement error. BMJ 313:744.

    Google Scholar 

  6. Shah S, Laiquzzaman M, Cunliffe I, Mantry S (2006) The use of the Reichert ocular response analyzer to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes. Cont Lens Anterior Eye 29:257–262

    Article  PubMed  Google Scholar 

  7. Kirwan C, O’Keefe M, Lanigan B (2006) Corneal hysteresis and intraocular pressure measurement in children using the Reichert ocular response analyzer. Am J Ophthalmol 142:990–992

    Article  PubMed  Google Scholar 

  8. Pepose JS, Feigenbaum SK, Qazi MA, Sanderson JP, Roberts CJ (2007) Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol 143:39–47

    Article  PubMed  Google Scholar 

  9. Hollo G, Follmann P, Pap G (1992) A clinical evaluation of XPERT NCT (Reichert) for glaucoma screening by optometrists. Int Ophthalmol 16:291–293

    Article  PubMed  CAS  Google Scholar 

  10. Baudouin C, Gastaud P (1994) Influence of topical anesthesia on tonometric values of intraocular pressure. Ophthalmologica 208:309–313

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. Ehongo.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ehongo, A., De Maertelaer, V. & Pourjavan, S. Effect of topical corneal anaesthesia on ocular response analyzer parameters: pilot study. Int Ophthalmol 29, 325–328 (2009). https://doi.org/10.1007/s10792-008-9239-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10792-008-9239-x

Keywords

Navigation