Comparison of the Calibration of Liquid-in-Glass Thermometers in the Range from \(-30\, ^{\circ }\hbox {C}\) to \(150\,^{\circ }\hbox {C}\)

  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

MIRS/UL-FE/LMK and MBM organized a bilateral comparison of a set of liquid-in-glass thermometers (LIGTs) in the range from \(-30\, ^{\circ }\hbox {C}\) to \(150\, ^{\circ }\hbox {C}\). The circulating items were three total immersion LIGTs, manufactured by Thermo Schneider, resolution of \(0.1\, ^{\circ }\hbox {C}\), covering range from \(-30\, ^{\circ }\hbox {C}\) to \(10\, ^{\circ }\hbox {C}\) (Serial Number 991289), \(0\, ^{\circ }\hbox {C}\) to \(50\, ^{\circ }\hbox {C}\) (Serial Number 9710425), and \(100\, ^{\circ }\hbox {C}\) to \(150\, ^{\circ }\hbox {C}\) (Serial Number 991308). The range between \(50\, ^{\circ }\hbox {C}\) and \(100\, ^{\circ }\hbox {C}\) has been already compared in another interlaboratory comparison. This interlaboratory comparison was also registered as EURAMET 1249 comparison project (comparison of the calibration of liquid-in-glass thermometers in the range from \(-30\, ^{\circ }\hbox {C}\) to \(150\, ^{\circ }\hbox {C}\)). The results of the comparison showed that all 18 pairs of measurements performed by the participating laboratories agree within declared uncertainties and thus supported declared calibration and measurement capabilities by MIRS/UL-FE/LMK and MBM.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Mutual Recognition of National Measurement Standards and of Calibration and Measurement Certificates Issued by the National Metrology Institutes (CIPM, Paris, 1999)

  2. J.V. Nicholas, D.R. White, Traceable Temperatures, 2nd edn. (Wiley, New York, 2001)

    Book  Google Scholar 

  3. J. Bojkovski, J. Drnovšek, I. Pušnik, Acceptable traceability of a distributed national metrological system, in Proceedings of IMTC’98 (St. Paul, MN, 1998), pp. 1260–1262

  4. J. Bojkovski, I. Pušnik, V. Batagelj, J. Drnovšek, in Proceedings of TEMPMEKO 2001, 8th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by B. Fellmuth, J. Seidel, G. Scholz (VDE Verlag, Berlin, 2002), pp. 559–563

  5. V. Batagelj, J. Bojkovski, J. Drnovšek, I. Pušnik, IEEE Trans. Instrum. Meas. 50, 1594 (2001)

    Article  Google Scholar 

  6. J. Wise, SP 250–23 Liquid-in-Glass Thermometer Calibration Service (National Institute of Standards and Technology, Gaithersburg, MD, 1988)

    Book  Google Scholar 

Download references

Acknowledgments

This work was partially supported by the Ministry of Economic Development and Technology, Metrology Institute of Republic Slovenia in scope of contract 6401-18/2008/70 for the national standard laboratory for the field of thermodynamic temperature and humidity.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Bojkovski.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Bojkovski, J., Vukicevic, T. Comparison of the Calibration of Liquid-in-Glass Thermometers in the Range from \(-30\, ^{\circ }\hbox {C}\) to \(150\,^{\circ }\hbox {C}\) . Int J Thermophys 36, 3502–3509 (2015). https://doi.org/10.1007/s10765-015-2005-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-015-2005-1

Keywords

Navigation