Abstract
The objective of Project EURAMET 1114 (Bilateral comparison of a freezing point of aluminum) in the field of thermometry is to compare realization of a freezing point of aluminum (660.323 °C) between the Dutch national laboratory VSL and the Slovenian national laboratory MIRS/UL-FE/LMK using a long-stem 25 Ω standard platinum resistance thermometer (SPRT). Both laboratories had participated in a number of inter-comparisons on the level of EURAMET and also on BIPM CCT level (VSL). MIRS/UL-FE/LMK laboratory recently acquired a new fixed-point cell which had to be validated in the process of intercomparison. A quartz-sheathed SPRT was selected and calibrated at MIRS/UL-FE/LMK at the aluminum freezing point and at the water triple point. A second set of measurements was made on the same SPRT and at the same fixed points at VSL (NL). After its return, the SPRT was again recalibrated at MIRS/UL-FE/LMK. In the comparison the W value of the SPRT was used. The results of the internal and external intercomparisons confirmed that the new aluminum cell of the MIRS/UL/FE-LMK realizes a temperature that agrees with the VSL aluminum fixed point within the uncertainty limits of both laboratories. Furthermore, the results of this bilateral-comparison were compared with results that both laboratories achieved in the EURAMET K4 (Project 820) and were found to be in agreement.
Similar content being viewed by others
References
Mutual Recognition of National Measurement Standards and of Calibration and Measurement Certificates Issued by the National Metrology Institutes (CIPM, Paris, 1999)
Renaot E., Hermier Y., Valin M.H., Bonnier G., Adunka F.: Int. J. Thermophys. 29, 991 (2008)
Heyer D., Noatsch U., Tegeler E., Anagnostou M., Turzo-Andras E., Antonsen I., Augevicius V., Bojkovski J., Bronnum A., Chimenti V., Duris S., Filipe E., Gaita S., Gray J., Head D., Grudneiwicz E., Ivarsson J., Kalemci M., Kerkhof O., Lobo I., Nemeth S., Pokhodun A., Ranostaj J., Renaot E., Rosenkranz P., Smid M., Steur P., Steiner A., Valin M., Veliki T., Weckström T.: Int. J. Thermophys. 28, 1964 (2007)
J. Bojkovski, J. Drnovšek, I. Pušnik, Acceptable Traceability of a Distributed National Metrological System, in Proceedings of the IEEE Instrumentation and Measurement Technology Conference, IMTC’98, St. Paul, Minnesota, 1998, pp. 1260–1262
J. Bojkovski, I. Pušnik, V. Batagelj, J. Drnovšek, Realization of the Temperature Scale in Slovenia, in Proceedings of TEMPMEKO 2001, 8th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by B. Fellmuth, J. Seidel, G. Scholz (VDE Verlag, Berlin, 2002), pp. 559–563
Hudoklin D., Drnovšek J.: Int. J. Thermophys. 29, 1652 (2008)
Pušnik I., Clausen S., Favreau J.-O., Gutschwager B., Doğan A.K., Diril A., Guven O.P., McEvoy H., Hoem S.S., Steiner A., van der Ham E.: Int. J. Thermophys. 32, 127 (2011)
Begeš G., Drnovšek J., Pendrill L.R: Accredit. Qual. Assur. 15, 147 (2010)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bojkovski, J., Peruzzi, A., Bosma, R. et al. Bilateral Comparison of Aluminum Fixed-Point Cells Using Standard Platinum Resistance Thermometer. Int J Thermophys 32, 1518–1524 (2011). https://doi.org/10.1007/s10765-011-1015-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10765-011-1015-x