Abstract

At the Physikalisch-Technische Bundesanstalt (PTB), absolutely-calibrated filter radiometers based on silicon photodiodes are routinely used for thermodynamic temperature determinations of blackbodies in the range from the zinc fixed point (FP) (419 °C) up to 3,000 °C. To extend the temperature range down to the tin FP (232 °C), we have designed two new filter radiometers based on indium gallium arsenide (InGaAs) photodiodes with center wavelengths at 1,300 nm and 1,550 nm. For the absolute calibration of the spectral irradiance responsivity of the new InGaAs filter radiometers, the spectral responsivity measurement in the near-infrared (NIR) spectral range has been significantly improved. With a newly developed tuneable laser and monochromator-based cryogenic radiometer facility, the relative standard uncertainty of the NIR spectral responsivity has been reduced from 0.17 % to about 0.03 %. By using the calibrated InGaAs filter radiometer in conjunction with the large-area double sodium heat pipe of the PTB, the first results for the difference between the thermodynamic temperature T and the ITS-90 temperature T 90 in the temperature range from the zinc FP up to the aluminum FP (660 °C) are presented. The values for T – T 90 determined with the new InGaAs filter radiometers are consistent within their relative standard uncertainty of about 30 mK at 419 °C to about 60 mK at 660 °C.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D.R. Taubert, J. Hartmann, J. Hollandt, J. Fischer, in Temperature, Its Measurement and Control in Science and Industry, vol. 7, ed. by D.C. Ripple (AIP, Melville, New York, 2003), pp. 7–12

  2. Werner L., Friedrich R., Johannsen U., Steiger A.: Metrologia 37, 523 (2000)

    Article  ADS  Google Scholar 

  3. Werner L., Fischer J., Johannsen U., Hartmann J.: Metrologia 37, 279 (2000)

    Article  ADS  Google Scholar 

  4. A.E. Klinkmüller, P. Meindl, U. Johannsen, N. Noulkhow, L. Werner, Improved NIR spectral responsivity scale of the PTB and implications for radiation thermometry, in Proceedings of the 9th International Conference on New Developments and Applications in Optical Radiometry (Newrad 2005), Davos, Switzerland (2005), p. 115

  5. P. Meindl, N. Noulkhow, A.E. Klinkmüller, U. Johannsen, L. Werner, New PTB detector calibration capability for spectral responsivity in the NIR range, in Proceedings of the 9th International Conference on Infrared Sensors & Systems (IRS 2 2006), Nürnberg, Germany (2006), pp. 213–215

  6. López M., Hofer H., Kück S.: Metrologia 43, 508 (2006)

    Article  ADS  Google Scholar 

  7. Taubert D.R., Friedrich R., Hartmann J., Hollandt J.: Metrologia 40, S35 (2003)

    Article  ADS  Google Scholar 

  8. Rusby R.L., Hudson R.P., Durieux M., Schooley J.F., Steur P.P.M., Swenson C.A.: Metrologia 28, 9 (1991)

    Article  ADS  Google Scholar 

  9. Meindl P., Klinkmüller A.E., Werner L., Johannsen U., Grützmacher K.: Metrologia 43, S72 (2006)

    Article  ADS  Google Scholar 

  10. Stock K.D., Heine R.: Metrologia 37, 449 (2000)

    Article  ADS  Google Scholar 

  11. Hartmann J., Fischer J., Seidel J.: Metrologia 37, 633 (2003)

    Google Scholar 

  12. Cox M.G., Siebert B.R.L.: Metrologia 43, S178 (2006)

    Article  ADS  Google Scholar 

  13. Boivin L.-P.: Appl. Optics 41, 1929 (2002)

    Article  ADS  Google Scholar 

  14. Stock M., Fischer J., Friedrich R., Jung H.J., Wende B.: Metrologia 32, 441 (1995/1996)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. D. Taubert.

Additional information

References to commercial products are for identification purposes only and constitute neither endorsement nor representation that the item identified is the best available for the stated purpose.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Noulkow, N., Taubert, R.D., Meindl, P. et al. Infrared Filter Radiometers for Thermodynamic Temperature Determination below 660 °C. Int J Thermophys 30, 131–143 (2009). https://doi.org/10.1007/s10765-008-0458-1

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-008-0458-1

Keywords

Navigation